Sign in

RR · Rural Residential

Kitsap County, WA · KCC 17.130 · Official code

By right: 1 unit, 2 units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family detached (includes manufactured homes)
Home✓ ADU✓1 H2
————
Mobile home
Home✓ ADU✓1 H2
————
Duplex—
Home✓ ADU✓1 H2
———
Single-family attached—
HomeH ADU✓1 H2
HomeH ADU✓1 H2
HomeH ADU✓1 H2
—
Manufactured/mobile/RV/park model/tiny home park———
HomeH ADU—
—
Adult family home————
Home✓ ADU✓1 H2
Permanent transitory accommodations, small, large, safe parks, and indoor————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size217,800 sq ft KCC 17.420.052; 17.420.060(A)(63)
Minimum lot width140 ft KCC 17.420.052; 17.420.060(A)(63)
Minimum lot depth140 ft KCC 17.420.052; 17.420.060(A)(63)
Minimum densityNo limit KCC 17.420.052; 17.420.040
Maximum density0.2 units per acre, a fraction of 0.5 or more rounds up KCC 17.420.052; 17.420.020(A)
Not set KCC 17.420.052
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum residents“Adult family home” means a dwelling licensed pursuant to Chapter 70.128 RCW in which a person or persons provide personal care, special care, and room and board to a number of persons consistent with the state definition. KCC 17.110.045
  • 25 persons3 KCC 17.505.040(B)
  • 50 persons4 KCC 17.505.040(C)
  • 25 persons5 KCC 17.505.040(D)
  • 75 persons6 KCC 17.505.040(E)
for Permanent transitory accommodations, small, large, safe parks, and indoor (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 100 ft7 KCC 17.420.060(A)(29)
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.8 KCC 17.420.060(A)(41)
  • 50 ft9 KCC 17.420.052; 17.420.060(A)(29)
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.10 KCC 17.420.060(A)(41)
  • 50 ft11 KCC 17.420.052; 17.420.060(A)(29)
for Duplex (2 units); Manufactured/mobile/RV/park model/tiny home park (4+ units); Adult family home (group living)
50 ft KCC 17.420.052; 17.420.060(A)(29)
for Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum front setbackNo limit KCC 17.420.052; 17.420.040
Side setback
  • 100 ft7 KCC 17.420.060(A)(29)
  • 20 ft12 KCC 17.420.052; 17.420.060(A)(29)
20 ft KCC 17.420.052; 17.420.060(A)(29)
for Duplex (2 units); Manufactured/mobile/RV/park model/tiny home park (4+ units); Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Rear setback
  • 100 ft7 KCC 17.420.060(A)(29)
  • 20 ft12 KCC 17.420.052; 17.420.060(A)(29)
20 ft KCC 17.420.052; 17.420.060(A)(29)
for Duplex (2 units); Manufactured/mobile/RV/park model/tiny home park (4+ units); Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum height
  • 28 ft13 KCC 17.420.060(A)(50)
  • 35 ft14 KCC 17.420.052; 17.420.060(A)(2)
Maximum lot coverageNo limit KCC 17.420.052; 17.420.040
Maximum impervious surfaceNo limit KCC 17.420.052; 17.420.040
Minimum parking2 spaces per unit KCC 17.490.030
Other uses not specifically listed above shall furnish parking as required by the director. The director shall use the above list as a guide for determining requirements for said other uses. KCC 17.490.030(B)(1)
for Manufactured/mobile/RV/park model/tiny home park (4+ units); Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum lot sizeNo limit KCC 17.420.052; 17.420.040

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit KCC 17.415.015(A)(4); 17.415.015(A)(6)

Building

StandardValueExceptions
Front setback
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.10 KCC 17.420.060(A)(41)
  • 50 ft11 KCC 17.420.052; 17.420.060(A)(29)
Side setback20 ft KCC 17.420.052; 17.420.060(A)(29)
Rear setback20 ft KCC 17.420.052; 17.420.060(A)(29)
Maximum height
  • 28 ft13 KCC 17.420.060(A)(50)
  • 35 ft14 KCC 17.420.052; 17.420.060(A)(2)
Minimum parking1 space per unit KCC 17.415.015(A)(5); 17.490.030
Maximum unit size0.5 × floor area of the main house sq ft KCC 17.415.015(A)(2)
the smallest of 0.5 × floor area of the main house, 900 sq ft KCC 17.415.015(B)(3)
for Single-family detached (includes manufactured homes) (1 unit)2; Mobile home (1 unit)2; Duplex (2 units)2; Single-family attached (2, 3, 4+ units)2; Adult family home (group living)2
Attached to the main houseRequired KCC 17.415.015(A)(1); 17.110.017
Not required KCC 17.415.015(B); 17.110.020
for Single-family detached (includes manufactured homes) (1 unit)2; Mobile home (1 unit)2; Duplex (2 units)2; Single-family attached (2, 3, 4+ units)2; Adult family home (group living)2
Owner lives on siteRequired KCC 17.415.015(A)(1)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision KCC 16.48.020 A up to 4 KCC 16.10.320(B) —
Minimum lot size
217,800 sq ft KCC 17.420.052; 17.420.060(A)(63)
Minimum lot width
140 ft KCC 17.420.052; 17.420.060(A)(63)
Minimum lot depth
140 ft KCC 17.420.052; 17.420.060(A)(63)
Subdivision KCC 16.40.030 H 5 or more KCC 16.10.340 —
Minimum lot size
217,800 sq ft KCC 17.420.052; 17.420.060(A)(63)
Minimum lot width
140 ft KCC 17.420.052; 17.420.060(A)(63)
Minimum lot depth
140 ft KCC 17.420.052; 17.420.060(A)(63)
Large lot subdivision KCC 16.52.020 A 2 or more KCC 16.10.190 —
Minimum lot size
217,800 sq ft KCC 16.10.190; 17.420.052
Minimum lot width
140 ft KCC 17.420.052; 17.420.060(A)(63)
Minimum lot depth
140 ft KCC 17.420.052; 17.420.060(A)(63)
Binding site plan KCC 16.56.040 A15
Minimum lots
Not set KCC 16.56
—
Minimum lot size
217,800 sq ft KCC 17.420.052; 17.420.060(A)(63); 16.56.030(A)
Minimum lot width
140 ft KCC 17.420.052; 17.420.060(A)(63); 16.56.030(A)
Minimum lot depth
140 ft KCC 17.420.052; 17.420.060(A)(63); 16.56.030(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The ADU is detached (not within or connected by at least 4 ft to the habitable space of the primary residence)
  2. The ADU is detached (not within or connected by at least 4 ft to the habitable space of the primary residence)
  3. Type of transitory accommodation is small
  4. Type of transitory accommodation is large
  5. Type of transitory accommodation is safe_park
  6. Type of transitory accommodation is indoor
  7. Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  8. All of these are true:
    • One or both abutting lots have dwellings with front yards less than the required depth
    None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  9. None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
    • One or both abutting lots have dwellings with front yards less than the required depth
  10. One or both abutting lots have dwellings with front yards less than the required depth
  11. None of these is true:
    • One or both abutting lots have dwellings with front yards less than the required depth
  12. None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  13. Lot is in the Illahee View Protection Overlay (Appendix B1)
  14. None of these is true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
  15. The land is divided through a condominium process under Chapter 64.32 or 64.34 RCW