Sign in

UM · Urban Medium Residential

Kitsap County, WA · KCC 17.220 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family detached (includes manufactured homes)
Home✓ ADU✓
————
Mobile home
Home✓ ADU✓
————
Duplex—
Home✓ ADU✓
———
Single-family attached—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Cottage housing development—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Multiple-family——
Home✓ ADU—
Home✓ ADU—
—
Manufactured/mobile/RV/park model/tiny home park———
HomeA ADU—
—
Adult family home————
Home✓ ADU✓
Group living————
Home✓1 ✓2 ADU—
Permanent transitory accommodations, small, large, safe parks, and indoor————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040
Minimum lot widthNo limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040
Minimum lot depthNo limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040
Minimum density10 units per acre KCC 17.420.052
Not set KCC 17.420.052
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)1; Group living (group living)2
Maximum density30 units per acre, a fraction of 0.5 or more rounds up KCC 17.420.052; 17.420.020(A)
Not set KCC 17.420.052
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)1; Group living (group living)2
Maximum residentsNot set KCC 17.415.250
“Adult family home” means a dwelling licensed pursuant to Chapter 70.128 RCW in which a person or persons provide personal care, special care, and room and board to a number of persons consistent with the state definition. KCC 17.110.045
for Adult family home (group living)
  • 25 persons3 KCC 17.505.040(B)
  • 50 persons4 KCC 17.505.040(C)
  • 25 persons5 KCC 17.505.040(D)
  • 75 persons6 KCC 17.505.040(E)
for Permanent transitory accommodations, small, large, safe parks, and indoor (group living)

3. Building standards

StandardValueExceptions
Front setback
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.7 KCC 17.420.060(A)(41)
  • 10 ft8 KCC 17.420.052; 17.420.060(A)(29)
  • 100 ft9 KCC 17.420.060(A)(29)
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.10 KCC 17.420.060(A)(41)
  • 10 ft11 KCC 17.420.052; 17.420.060(A)(29)
for Single-family detached (includes manufactured homes) (1 unit); Mobile home (1 unit); Single-family attached (2, 3, 4+ units)
10 ft KCC 17.420.052; 17.420.060(A)(29)
for Group living (group living)1; Group living (group living)2; Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum front setbackNo limit KCC 17.420.052; 17.420.040
Side setback5 ft KCC 17.420.052; 17.420.060(A)(29)
  • 100 ft9 KCC 17.420.060(A)(29)
  • 5 ft12 KCC 17.420.052; 17.420.060(A)(29)
for Single-family detached (includes manufactured homes) (1 unit); Mobile home (1 unit)
  • 100 ft9 KCC 17.420.060(A)(29)
  • 0 ft12 KCC 17.420.052; 17.420.060(A)(29)
for Single-family attached (2, 3, 4+ units)
Rear setback10 ft KCC 17.420.052; 17.420.060(A)(29)
  • 100 ft9 KCC 17.420.060(A)(29)
  • 10 ft12 KCC 17.420.052; 17.420.060(A)(29)
for Single-family detached (includes manufactured homes) (1 unit); Mobile home (1 unit); Single-family attached (2, 3, 4+ units)
Building separationNot set KCC 17.420.052
10 ft KCC 17.415.135(B)
for Cottage housing development (2, 3, 4+ units)
Maximum height
  • 28 ft13 KCC 17.420.060(A)(50)
  • 45 ft14 KCC 17.420.052
24 ft KCC 17.415.135(C)
for Cottage housing development (2, 3, 4+ units)
  • 28 ft15 KCC 17.420.060(A)(50)
  • 28 ft16 KCC 17.420.060(A)(50)
  • 55 ft17 KCC 17.420.052; 17.420.060(A)(17); 17.420.035
  • 45 ft18 KCC 17.420.052
for Multiple-family (3, 4+ units)
Maximum lot coverage85% KCC 17.420.052
50% KCC 17.415.135(A)
for Cottage housing development (2, 3, 4+ units)
Maximum impervious surface85% KCC 17.420.052
Minimum parking2 spaces per unit KCC 17.490.030
  • 0.75 spaces per unit19 KCC 17.490.030
  • 0.75 spaces per unit20 KCC 17.490.030
  • 1 space per unit21 KCC 17.490.030
  • 2 spaces per unit22 KCC 17.490.030
  • 1.5 spaces per unit23 KCC 17.490.030
  • 2 spaces per unit24 KCC 17.490.030
for Cottage housing development (2, 3, 4+ units); Multiple-family (3, 4+ units)
Other uses not specifically listed above shall furnish parking as required by the director. The director shall use the above list as a guide for determining requirements for said other uses. KCC 17.490.030(B)(1)
for Manufactured/mobile/RV/park model/tiny home park (4+ units); Adult family home (group living); Group living (group living)1; Group living (group living)2; Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum unit sizeNot set KCC 17.420.052
1,200 sq ft KCC 17.415.135(D)
for Cottage housing development (2, 3, 4+ units)
Maximum lot sizeNo limit KCC 17.420.052; 17.420.040

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units KCC 17.415.010(A)

Building

StandardValueExceptions
Front setback
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.7 KCC 17.420.060(A)(41)
  • 10 ft8 KCC 17.420.052; 17.420.060(A)(29)
Side setback5 ft KCC 17.420.052; 17.420.060(A)(29)
Rear setback10 ft KCC 17.420.052; 17.420.060(A)(29)
Maximum height
  • 28 ft13 KCC 17.420.060(A)(50)
  • 45 ft14 KCC 17.420.052
Minimum parking
  • the largest of ADUs on the lot − 1, 0 spaces25 KCC 17.415.010(H); 17.490.030
  • 1 space per unit26 KCC 17.415.010(H); 17.490.030
Maximum unit size1,000 sq ft KCC 17.415.010(G)
Attached to the main houseNot required KCC 17.410.042

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision KCC 16.48.020 A up to 9 KCC 16.10.320(A) —
Minimum lot size
No limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040
Minimum lot width
No limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040
Minimum lot depth
No limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040
Subdivision KCC 16.40.030 H 10 or more KCC 16.10.340 —
Minimum lot size
No limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040
Minimum lot width
No limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040
Minimum lot depth
No limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040
Binding site plan KCC 16.56.040 A27
Minimum lots
Not set KCC 16.56
—
Minimum lot size
No limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040; 16.56.030(A)
Minimum lot width
No limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040; 16.56.030(A)
Minimum lot depth
No limit KCC 17.420.052; 17.420.060(A)(63); 17.420.040; 16.56.030(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Sleeping units in the project is at most 6
  2. Sleeping units in the project is more than 6
  3. Type of transitory accommodation is small
  4. Type of transitory accommodation is large
  5. Type of transitory accommodation is safe_park
  6. Type of transitory accommodation is indoor
  7. One or both abutting lots have dwellings with front yards less than the required depth
  8. None of these is true:
    • One or both abutting lots have dwellings with front yards less than the required depth
  9. Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  10. All of these are true:
    • One or both abutting lots have dwellings with front yards less than the required depth
    None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  11. None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
    • One or both abutting lots have dwellings with front yards less than the required depth
  12. None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  13. Lot is in the Illahee View Protection Overlay (Appendix B1)
  14. None of these is true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
  15. All of these are true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
    • The project qualifies as mixed use or multifamily development and meets the modification or waiver request criteria of 17.420.035 for height
  16. All of these are true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
    None of these is true:
    • The project qualifies as mixed use or multifamily development and meets the modification or waiver request criteria of 17.420.035 for height
  17. All of these are true:
    • The project qualifies as mixed use or multifamily development and meets the modification or waiver request criteria of 17.420.035 for height
    None of these is true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
  18. None of these is true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
    • The project qualifies as mixed use or multifamily development and meets the modification or waiver request criteria of 17.420.035 for height
  19. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • The housing unit is affordable to very low-income or extremely low-income individuals
  20. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • Bedrooms in one unit is at most 0
    None of these is true:
    • The housing unit is affordable to very low-income or extremely low-income individuals
  21. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • Bedrooms in one unit is 1
    None of these is true:
    • The housing unit is affordable to very low-income or extremely low-income individuals
  22. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • Bedrooms in one unit is at least 2
    None of these is true:
    • The housing unit is affordable to very low-income or extremely low-income individuals
  23. All of these are true:
    • Bedrooms in one unit is at most 1
    None of these is true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
  24. All of these are true:
    • Bedrooms in one unit is at least 2
    None of these is true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
  25. Any of these is true:
    • The primary dwelling unit meets all parking requirements
    • On-street parking is available
    • The ADU is within one-half mile of a major transit stop as defined in RCW 36.70A.696(8)
  26. None of these is true:
    • The primary dwelling unit meets all parking requirements
    • On-street parking is available
    • The ADU is within one-half mile of a major transit stop as defined in RCW 36.70A.696(8)
  27. The land is divided through a condominium process under Chapter 64.32 or 64.34 RCW