Sign in

UVC · Urban Village Center

Kitsap County, WA · KCC 17.260 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family detached (includes manufactured homes)
Home✓ ADU✓
————
Duplex—
Home✓ ADU✓
———
Single-family attached—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Cottage housing development—
HomeA ADU—
HomeA ADU—
HomeA ADU—
—
Multiple-family——
Home✓ ADU—
Home✓ ADU—
—
Adult family home————
Home✓ ADU✓
Group living————
Home✓1 ✓2 ADU—
Permanent transitory accommodations, small, large, safe parks, and indoor————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit KCC 17.420.054; 17.420.040
Minimum lot widthNo limit KCC 17.420.054; 17.420.040
Minimum lot depthNo limit KCC 17.420.054; 17.420.040
Minimum density
  • No limit3 KCC 17.420.054; 17.420.060(A)(57)
  • 10 units per acre4 KCC 17.420.054; 17.420.060(A)(57)
Not set KCC 17.420.054
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)1; Group living (group living)2
Maximum densityNo limit KCC 17.420.054; 17.420.040
Not set KCC 17.420.054
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)1; Group living (group living)2
Maximum residentsNot set KCC 17.415.250
“Adult family home” means a dwelling licensed pursuant to Chapter 70.128 RCW in which a person or persons provide personal care, special care, and room and board to a number of persons consistent with the state definition. KCC 17.110.045
for Adult family home (group living)
  • 25 persons5 KCC 17.505.040(B)
  • 50 persons6 KCC 17.505.040(C)
  • 25 persons7 KCC 17.505.040(D)
  • 75 persons8 KCC 17.505.040(E)
for Permanent transitory accommodations, small, large, safe parks, and indoor (group living)

3. Building standards

StandardValueExceptions
Front setbackNo limit KCC 17.420.054; 17.420.060(A)(29); 17.420.040
  • 100 ft9 KCC 17.420.060(A)(29)
  • No limit10 KCC 17.420.054; 17.420.060(A)(29); 17.420.040
for Single-family detached (includes manufactured homes) (1 unit); Single-family attached (2, 3, 4+ units)
Maximum front setbackNo limit KCC 17.420.054; 17.420.040
Side setbackNo limit KCC 17.420.054; 17.420.060(A)(29); 17.420.040
  • 100 ft9 KCC 17.420.060(A)(29)
  • No limit10 KCC 17.420.054; 17.420.060(A)(29); 17.420.040
for Single-family detached (includes manufactured homes) (1 unit); Single-family attached (2, 3, 4+ units)
Rear setbackNo limit KCC 17.420.054; 17.420.060(A)(29); 17.420.040
  • 100 ft9 KCC 17.420.060(A)(29)
  • No limit10 KCC 17.420.054; 17.420.060(A)(29); 17.420.040
for Single-family detached (includes manufactured homes) (1 unit); Single-family attached (2, 3, 4+ units)
Building separationNot set KCC 17.420.054
10 ft KCC 17.415.135(B)
for Cottage housing development (2, 3, 4+ units)
Maximum height
  • 28 ft11 KCC 17.420.060(A)(50)
  • 45 ft12 KCC 17.420.054
24 ft KCC 17.415.135(C)
for Cottage housing development (2, 3, 4+ units)
Maximum lot coverageNot set KCC 17.420.054
50% KCC 17.415.135(A)
for Cottage housing development (2, 3, 4+ units)
Maximum impervious surface85% KCC 17.420.054
Minimum parking2 spaces per unit KCC 17.490.030
  • 0.75 spaces per unit13 KCC 17.490.030
  • 0.75 spaces per unit14 KCC 17.490.030
  • 1 space per unit15 KCC 17.490.030
  • 2 spaces per unit16 KCC 17.490.030
  • 1.5 spaces per unit17 KCC 17.490.030
  • 2 spaces per unit18 KCC 17.490.030
for Cottage housing development (2, 3, 4+ units); Multiple-family (3, 4+ units)
Other uses not specifically listed above shall furnish parking as required by the director. The director shall use the above list as a guide for determining requirements for said other uses. KCC 17.490.030(B)(1)
for Adult family home (group living); Group living (group living)1; Group living (group living)2; Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum unit sizeNot set KCC 17.420.054
1,200 sq ft KCC 17.415.135(D)
for Cottage housing development (2, 3, 4+ units)
Maximum lot sizeNo limit KCC 17.420.054; 17.420.040

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units KCC 17.415.010(A)

Building

StandardValueExceptions
Front setbackNo limit KCC 17.420.054; 17.420.060(A)(29); 17.420.040
Side setbackNo limit KCC 17.420.054; 17.420.060(A)(29); 17.420.040
Rear setbackNo limit KCC 17.420.054; 17.420.060(A)(29); 17.420.040
Maximum height
  • 28 ft11 KCC 17.420.060(A)(50)
  • 45 ft12 KCC 17.420.054
Minimum parking
  • the largest of ADUs on the lot − 1, 0 spaces19 KCC 17.415.010(H); 17.490.030
  • 1 space per unit20 KCC 17.415.010(H); 17.490.030
Maximum unit size1,000 sq ft KCC 17.415.010(G)
Attached to the main houseNot required KCC 17.410.044

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision KCC 16.48.020 A up to 9 KCC 16.10.320(A) —
Minimum lot size
No limit KCC 17.420.054; 17.420.040
Minimum lot width
No limit KCC 17.420.054; 17.420.040
Minimum lot depth
No limit KCC 17.420.054; 17.420.040
Subdivision KCC 16.40.030 H 10 or more KCC 16.10.340 —
Minimum lot size
No limit KCC 17.420.054; 17.420.040
Minimum lot width
No limit KCC 17.420.054; 17.420.040
Minimum lot depth
No limit KCC 17.420.054; 17.420.040
Binding site plan KCC 16.56.040 A
Minimum lots
Not set KCC 16.56
—
Minimum lot size
No limit KCC 17.420.054; 17.420.040; 16.56.030(A)
Minimum lot width
No limit KCC 17.420.054; 17.420.040; 16.56.030(A)
Minimum lot depth
No limit KCC 17.420.054; 17.420.040; 16.56.030(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Sleeping units in the project is at most 6
  2. Sleeping units in the project is more than 6
  3. The project is a mixed use project
  4. None of these is true:
    • The project is a mixed use project
  5. Type of transitory accommodation is small
  6. Type of transitory accommodation is large
  7. Type of transitory accommodation is safe_park
  8. Type of transitory accommodation is indoor
  9. Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  10. None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  11. Lot is in the Illahee View Protection Overlay (Appendix B1)
  12. None of these is true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
  13. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • The housing unit is affordable to very low-income or extremely low-income individuals
  14. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • Bedrooms in one unit is at most 0
    None of these is true:
    • The housing unit is affordable to very low-income or extremely low-income individuals
  15. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • Bedrooms in one unit is 1
    None of these is true:
    • The housing unit is affordable to very low-income or extremely low-income individuals
  16. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • Bedrooms in one unit is at least 2
    None of these is true:
    • The housing unit is affordable to very low-income or extremely low-income individuals
  17. All of these are true:
    • Bedrooms in one unit is at most 1
    None of these is true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
  18. All of these are true:
    • Bedrooms in one unit is at least 2
    None of these is true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
  19. Any of these is true:
    • The primary dwelling unit meets all parking requirements
    • On-street parking is available
    • The ADU is within one-half mile of a major transit stop as defined in RCW 36.70A.696(8)
  20. None of these is true:
    • The primary dwelling unit meets all parking requirements
    • On-street parking is available
    • The ADU is within one-half mile of a major transit stop as defined in RCW 36.70A.696(8)