C-1 · Downtown Commercial (C-1)
La Center, WA · LCMC 18.150 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Medium density (integrated multifamily/commercial or mixed-use structure not to exceed 22 residential units per net acre) | — | ||||
| Residential care homes | — | — | — | — | HomeH ADU— |
| Residential and congregate care facilities | — | — | — | — | HomeH ADU— |
| Sanitaria, convalescent and rest homes | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 2,500 sq ft LCMC 18.150.030(1), Table 18.150.030(1) | |
| Minimum lot width | 25 ft LCMC 18.150.030(1), Table 18.150.030(1) | |
| Minimum lot depth | 80 ft LCMC 18.150.030(1), Table 18.150.030(1) | |
| Maximum density | 22 units per acre, on the net lot area LCMC 18.150.020, Table 18.150.020 row 1.a | Not set LCMC 18.150.020
for Residential care homes (group living); Residential and congregate care facilities (group living); Sanitaria, convalescent and rest homes (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Maximum front setback | 10 ft LCMC 18.150.030(4)(b)(iii) | |
| Side setback |
|
|
| Street side setback |
|
|
| Rear setback |
|
|
| Maximum height | 60 ft LCMC 18.150.030(1), Table 18.150.030(2) | |
| Maximum lot coverage | Maximum determined by compliance with screening and buffering standards contained in Chapters 18.245 and 18.320 LCMC, and all other applicable standards. LCMC 18.150.030(1), Table 18.150.030(2) | |
| Minimum parking | (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5), rounded up spaces LCMC 18.280.040(1)-(2) | For uses not listed in Table 18.280.040, the review authority shall determine the required number of parking spaces by selecting the use with the most similar parking demand requirements. LCMC 18.280.040(3)
for Residential care homes (group living); Sanitaria, convalescent and rest homes (group living) 0.3 spaces per unit LCMC 18.280.040(1)
for Residential and congregate care facilities (group living) |
| Minimum open space |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision LCMC 18.205.020(2) | A | up to 4 LCMC 18.40.010 | — | Minimum lot size 2,500 sq ft LCMC 18.150.030(1), Table 18.150.030(1) Minimum lot width 25 ft LCMC 18.150.030(1), Table 18.150.030(1) Minimum lot depth 80 ft LCMC 18.150.030(1), Table 18.150.030(1) |
| Subdivision LCMC 18.210.020(2) | H | 5 or more LCMC 18.40.010 | — | Minimum lot size 2,500 sq ft LCMC 18.150.030(1), Table 18.150.030(1) Minimum lot width 25 ft LCMC 18.150.030(1), Table 18.150.030(1) Minimum lot depth 80 ft LCMC 18.150.030(1), Table 18.150.030(1) |
| Binding site plan LCMC 18.215.040(1)(c) | A6 | Maximum lots Not set LCMC 18.215.040(1)(c) |
— | Minimum lot size 2,500 sq ft LCMC 18.150.030(1), Table 18.150.030(1) Minimum lot width 25 ft LCMC 18.150.030(1), Table 18.150.030(1) Minimum lot depth 80 ft LCMC 18.150.030(1), Table 18.150.030(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The dwellings are in an integrated multifamily/commercial or mixed-use structure with ground floor retail, services, or offices
- The setback is adjacent to a residential district
- None of these is true:
- The setback is adjacent to a residential district
- The project is a zero lot line development
- None of these is true:
- The project is a zero lot line development
- The property divided is commercial or industrial property