Sign in

JP · Junction Plan (JP)

La Center, WA · LCMC 18.158 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Attached housing—
Home✓1 ✓2 ✓3 ADU—
Home✓1 ✓2 ✓3 ADU—
Home✓1 ✓2 ✓3 ADU—
—
Cottage housing———
HomeH4 ADU—
—
Adult family homes————
HomeH2 H4 ADU—
Assisted living facility————
Home✓4 H1 ADU—
Residential care facilities such as senior living, assisted living, memory care————
Home✓2 H4 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units80 units LCMC 18.158.050(1)(c)
Not set LCMC 18.158.040
for Attached housing (4+ units)3
12 units LCMC 18.185.040(1)
for Cottage housing (4+ units)4
Minimum unitsNot set LCMC 18.158.040
4 units LCMC 18.185.040(1)
for Cottage housing (4+ units)4
Minimum lot sizeNot set LCMC 18.158.040
2,000 sq ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4
Minimum density12 units per acre LCMC 18.158.050(1)(c); 18.158.050(2), Table 18.158.050-1 row 1.c
Not set LCMC 18.185.040
for Cottage housing (4+ units)4; Adult family homes (group living)2; Adult family homes (group living)4; Assisted living facility (group living)1; Assisted living facility (group living)4; Residential care facilities such as senior living, assisted living, memory care (group living)2; Residential care facilities such as senior living, assisted living, memory care (group living)4
Maximum residentsNot set LCMC 18.158.050
6 persons LCMC 18.40.010
for Adult family homes (group living)2; Adult family homes (group living)4

3. Building standards

StandardValueExceptions
Front setbackThe building facade shall be built to the required building line (RBL) except for 45-degree corner entrances, or designated corner pedestrian plazas. LCMC 18.158.030(2)(b)
On each lot the building facade shall be built parallel to the required building line for at least 60 percent of the required building line (RBL) length. The front porch, if provided, shall be built to the RBL. Within 20 feet of a block corner, the building facade shall be eight to 10 feet behind the RBL. LCMC 18.158.060(4)(a)(i)-(iii)
for Attached housing (2, 3, 4+ units)3; Adult family homes (group living)4; Assisted living facility (group living)4; Residential care facilities such as senior living, assisted living, memory care (group living)4
10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4
Maximum front setbackThe building facade shall be built to the required building line (RBL) except for 45-degree corner entrances, or designated corner pedestrian plazas. LCMC 18.158.030(2)(b)
On each lot the building facade shall be built parallel to the required building line for at least 60 percent of the required building line (RBL) length. The front porch, if provided, shall be built to the RBL. Within 20 feet of a block corner, the building facade shall be eight to 10 feet behind the RBL. LCMC 18.158.060(4)(a)(i)-(iii)
for Attached housing (2, 3, 4+ units)3; Adult family homes (group living)4; Assisted living facility (group living)4; Residential care facilities such as senior living, assisted living, memory care (group living)4
Not set LCMC 18.185.040
for Cottage housing (4+ units)4
Side setback5 ft LCMC 18.158.060(4)(c)(i)
  • 10 ft5 LCMC 18.158.060(1)(b)(i)
  • 0 ft6 LCMC 18.158.060(1)(b)(i)
for Attached housing (2, 3, 4+ units)1; Assisted living facility (group living)1
  • 15 ft5 LCMC 18.158.060(2)(b)(i)
  • 0 ft6 LCMC 18.158.060(2)(b)(i)
for Attached housing (2, 3, 4+ units)2; Adult family homes (group living)2; Residential care facilities such as senior living, assisted living, memory care (group living)2
10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4
Street side setbackNot set LCMC 18.158.060
10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4
Rear setback10 ft LCMC 18.158.060(1)(b)(ii)
Building separationNot set LCMC 18.158.060
10 ft LCMC 18.185.040(3), Table 18.185.040 note 2
for Cottage housing (4+ units)4
Maximum height60 ft LCMC 18.158.040(1), Table 18.158.040-1 row a.i
  • 60 ft7 LCMC 18.158.030(5)(a)(ii)
  • 45 ft8 LCMC 18.158.040(1), Table 18.158.040-1 row a.i; 18.158.030(5)(a)(i)
for Attached housing (2, 3, 4+ units)3
25 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4
45 ft LCMC 18.158.040(1), Table 18.158.040-1 row a.i; 18.158.030(5)(a)(i)
for Adult family homes (group living)4; Assisted living facility (group living)4; Residential care facilities such as senior living, assisted living, memory care (group living)4
Maximum storiesNot set LCMC 18.158.040
2 stories LCMC 18.185.060(1)
for Cottage housing (4+ units)4
Maximum lot coverageNot set LCMC 18.158.040
45% LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4
Maximum impervious surfaceNot set LCMC 18.158.040
60% LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4
Minimum parking(2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5), rounded up spaces LCMC 18.280.040(1)-(2); 18.158.080(4)(a)
3 spaces per unit LCMC 18.280.040(1); 18.185.130(1)(h)
for Cottage housing (4+ units)4
For uses not listed in Table 18.280.040, the review authority shall determine the required number of parking spaces by selecting the use with the most similar parking demand requirements. LCMC 18.280.040(3)
for Adult family homes (group living)2; Adult family homes (group living)4; Residential care facilities such as senior living, assisted living, memory care (group living)2; Residential care facilities such as senior living, assisted living, memory care (group living)4
0.4 spaces per unit LCMC 18.280.040(1)
for Assisted living facility (group living)1; Assisted living facility (group living)4
Maximum unit sizeNot set LCMC 18.158.040
1.5 × 1,000 sq ft LCMC 18.185.060(1)(a)-(b)
for Cottage housing (4+ units)4
Maximum building footprint50,000 sq ft LCMC 18.158.030(2)(h)
1,000 sq ft LCMC 18.185.060(1)(a)
for Cottage housing (4+ units)4
Minimum open spaceNot set LCMC 18.158.060(1)
A contiguous open space area equal to at least 20 percent of the total buildable area shall be preserved on every lot for park activity. The contiguous open area may be located anywhere behind the parking setback, at grade. LCMC 18.158.060(4)(b)
for Attached housing (2, 3, 4+ units)3; Adult family homes (group living)4; Assisted living facility (group living)4; Residential care facilities such as senior living, assisted living, memory care (group living)4

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision LCMC 18.205.020(2) A up to 4 LCMC 18.40.010 —
Minimum lot size
Not set LCMC 18.158.040
Minimum lot width
Not set LCMC 18.158.040
Minimum lot depth
Not set LCMC 18.158.040
Subdivision LCMC 18.210.020(2) H 5 or more LCMC 18.40.010 —
Minimum lot size
Not set LCMC 18.158.040
Minimum lot width
Not set LCMC 18.158.040
Minimum lot depth
Not set LCMC 18.158.040
Binding site plan LCMC 18.215.040(1)(c) A9
Maximum lots
Not set LCMC 18.215.040(1)(c)
—
Minimum lot size
Not set LCMC 18.158.040
Minimum lot width
Not set LCMC 18.158.040
Minimum lot depth
Not set LCMC 18.158.040

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The Junction Plan district of the lot on the Regulating Plan: town center, town general, town employment or town residential mixed-use is TC
    • The dwellings are above the first floor
    • The ground story houses commercial or employment uses
  2. All of these are true:
    • The Junction Plan district of the lot on the Regulating Plan: town center, town general, town employment or town residential mixed-use is TG
    • The dwellings are above the first floor
    • The ground story houses commercial or employment uses
  3. All of these are true:
    • The Junction Plan district of the lot on the Regulating Plan: town center, town general, town employment or town residential mixed-use is TRx
    • Residential use is at most 75 percent of the project floor area
  4. The Junction Plan district of the lot on the Regulating Plan: town center, town general, town employment or town residential mixed-use is TRx
  5. The lot shares a common lot line with a property in the TRx district
  6. None of these is true:
    • The lot shares a common lot line with a property in the TRx district
  7. The multifamily building has parking under the building for at least 75 percent of the building ground floor area
  8. None of these is true:
    • The multifamily building has parking under the building for at least 75 percent of the building ground floor area
  9. The property divided is commercial or industrial property