JP · Junction Plan (JP)
La Center, WA · LCMC 18.158 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Attached housing | — | — | |||
| Cottage housing | — | — | — | — | |
| Adult family homes | — | — | — | — | |
| Assisted living facility | — | — | — | — | |
| Residential care facilities such as senior living, assisted living, memory care | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 80 units LCMC 18.158.050(1)(c) | Not set LCMC 18.158.040
for Attached housing (4+ units)3 12 units LCMC 18.185.040(1)
for Cottage housing (4+ units)4 |
| Minimum units | Not set LCMC 18.158.040 | 4 units LCMC 18.185.040(1)
for Cottage housing (4+ units)4 |
| Minimum lot size | Not set LCMC 18.158.040 | 2,000 sq ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4 |
| Minimum density | 12 units per acre LCMC 18.158.050(1)(c); 18.158.050(2), Table 18.158.050-1 row 1.c | Not set LCMC 18.185.040
for Cottage housing (4+ units)4; Adult family homes (group living)2; Adult family homes (group living)4; Assisted living facility (group living)1; Assisted living facility (group living)4; Residential care facilities such as senior living, assisted living, memory care (group living)2; Residential care facilities such as senior living, assisted living, memory care (group living)4 |
| Maximum residents | Not set LCMC 18.158.050 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | The building facade shall be built to the required building line (RBL) except for 45-degree corner entrances, or designated corner pedestrian plazas. LCMC 18.158.030(2)(b) | On each lot the building facade shall be built parallel to the required building line for at least 60 percent of the required building line (RBL) length. The front porch, if provided, shall be built to the RBL. Within 20 feet of a block corner, the building facade shall be eight to 10 feet behind the RBL. LCMC 18.158.060(4)(a)(i)-(iii)
10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4 |
| Maximum front setback | The building facade shall be built to the required building line (RBL) except for 45-degree corner entrances, or designated corner pedestrian plazas. LCMC 18.158.030(2)(b) | On each lot the building facade shall be built parallel to the required building line for at least 60 percent of the required building line (RBL) length. The front porch, if provided, shall be built to the RBL. Within 20 feet of a block corner, the building facade shall be eight to 10 feet behind the RBL. LCMC 18.158.060(4)(a)(i)-(iii)
Not set LCMC 18.185.040
for Cottage housing (4+ units)4 |
| Side setback | 5 ft LCMC 18.158.060(4)(c)(i) | 10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4 |
| Street side setback | Not set LCMC 18.158.060 | 10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4 |
| Rear setback | 10 ft LCMC 18.158.060(1)(b)(ii) | |
| Building separation | Not set LCMC 18.158.060 | 10 ft LCMC 18.185.040(3), Table 18.185.040 note 2
for Cottage housing (4+ units)4 |
| Maximum height | 60 ft LCMC 18.158.040(1), Table 18.158.040-1 row a.i | for Attached housing (2, 3, 4+ units)3 25 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4 |
| Maximum stories | Not set LCMC 18.158.040 | 2 stories LCMC 18.185.060(1)
for Cottage housing (4+ units)4 |
| Maximum lot coverage | Not set LCMC 18.158.040 | 45% LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4 |
| Maximum impervious surface | Not set LCMC 18.158.040 | 60% LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)4 |
| Minimum parking | (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5), rounded up spaces LCMC 18.280.040(1)-(2); 18.158.080(4)(a) | 3 spaces per unit LCMC 18.280.040(1); 18.185.130(1)(h)
for Cottage housing (4+ units)4 For uses not listed in Table 18.280.040, the review authority shall determine the required number of parking spaces by selecting the use with the most similar parking demand requirements. LCMC 18.280.040(3)
|
| Maximum unit size | Not set LCMC 18.158.040 | 1.5 × 1,000 sq ft LCMC 18.185.060(1)(a)-(b)
for Cottage housing (4+ units)4 |
| Maximum building footprint | 50,000 sq ft LCMC 18.158.030(2)(h) | 1,000 sq ft LCMC 18.185.060(1)(a)
for Cottage housing (4+ units)4 |
| Minimum open space | Not set LCMC 18.158.060(1) | A contiguous open space area equal to at least 20 percent of the total buildable area shall be preserved on every lot for park activity. The contiguous open area may be located anywhere behind the parking setback, at grade. LCMC 18.158.060(4)(b)
|
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision LCMC 18.205.020(2) | A | up to 4 LCMC 18.40.010 | — | Minimum lot size Not set LCMC 18.158.040 Minimum lot width Not set LCMC 18.158.040 Minimum lot depth Not set LCMC 18.158.040 |
| Subdivision LCMC 18.210.020(2) | H | 5 or more LCMC 18.40.010 | — | Minimum lot size Not set LCMC 18.158.040 Minimum lot width Not set LCMC 18.158.040 Minimum lot depth Not set LCMC 18.158.040 |
| Binding site plan LCMC 18.215.040(1)(c) | A9 | Maximum lots Not set LCMC 18.215.040(1)(c) |
— | Minimum lot size Not set LCMC 18.158.040 Minimum lot width Not set LCMC 18.158.040 Minimum lot depth Not set LCMC 18.158.040 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The Junction Plan district of the lot on the Regulating Plan: town center, town general, town employment or town residential mixed-use is TC
- The dwellings are above the first floor
- The ground story houses commercial or employment uses
- All of these are true:
- The Junction Plan district of the lot on the Regulating Plan: town center, town general, town employment or town residential mixed-use is TG
- The dwellings are above the first floor
- The ground story houses commercial or employment uses
- All of these are true:
- The Junction Plan district of the lot on the Regulating Plan: town center, town general, town employment or town residential mixed-use is TRx
- Residential use is at most 75 percent of the project floor area
- The Junction Plan district of the lot on the Regulating Plan: town center, town general, town employment or town residential mixed-use is TRx
- The lot shares a common lot line with a property in the TRx district
- None of these is true:
- The lot shares a common lot line with a property in the TRx district
- The multifamily building has parking under the building for at least 75 percent of the building ground floor area
- None of these is true:
- The multifamily building has parking under the building for at least 75 percent of the building ground floor area
- The property divided is commercial or industrial property