LDR-7.5 · Low Density Residential District (LDR-7.5)
La Center, WA · LCMC 18.130 · Official code
By right: 1 unit, 2 units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family detached dwelling units | Home✓ ADUA | — | — | — | — |
| Manufactured homes | Home✓ ADUA | — | — | — | — |
| Duplexes | — | Home✓ ADU— | — | — | — |
| Manufactured home subdivisions and communities | — | HomeH ADU— | HomeH ADU— | HomeH ADU— | — |
| Cottage housing | — | — | — | — | |
| Foster care homes | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set LCMC 18.130.080 | 12 units LCMC 18.185.040(1)
for Cottage housing (4+ units)1 |
| Minimum units | Not set LCMC 18.130.080 | 4 units LCMC 18.185.040(1)
for Cottage housing (4+ units)1 |
| Minimum lot size | 7,500 sq ft LCMC 18.130.080(2) | 10,000 sq ft LCMC 18.130.080(2)(b)
for Duplexes (2 units) 3,750 sq ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)1 |
| Minimum lot width | 60 ft LCMC 18.130.080(8) | Not set LCMC 18.185.040
for Cottage housing (4+ units)1 |
| Minimum lot depth | 90 ft LCMC 18.130.080(8) | Not set LCMC 18.185.040
for Cottage housing (4+ units)1 |
| Minimum density | 4 units per acre LCMC 18.130.080(1) | Not set LCMC 18.130.080(1)
for Foster care homes (group living) |
| Maximum density | 5.8 units per acre, on the net lot area LCMC 18.130.080(1) | 8.7 units per acre, on the net lot area LCMC 18.130.080(1)
for Duplexes (2 units) 10 units per acre, on the net lot area LCMC 18.185.020(2)(b)
for Cottage housing (4+ units)1 Not set LCMC 18.130.080(1)
for Foster care homes (group living) |
| Maximum residents | 5 persons LCMC 18.40.010 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
for Single-family detached dwelling units (1 unit) 10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)1 |
| Side setback | 7.5 ft LCMC 18.130.080(8) | 10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)1 |
| Street side setback | 10 ft LCMC 18.130.080(8) | |
| Rear setback | 20 ft LCMC 18.130.080(8) | 10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)1 |
| Building separation | 6 ft LCMC 18.130.080(8), Table 18.130.080 note 3 | 10 ft LCMC 18.185.040(3), Table 18.185.040 note 2
for Cottage housing (4+ units)1 |
| Maximum height | 35 ft LCMC 18.130.070 | 25 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)1 |
| Maximum stories | Not set LCMC 18.130.070 | 2 stories LCMC 18.185.060(1)
for Cottage housing (4+ units)1 |
| Maximum lot coverage | 35% LCMC 18.130.080(5) | 45% LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)1 |
| Maximum impervious surface | 50% LCMC 18.130.080(5) | 60% LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)1 |
| Minimum parking | (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5), rounded up spaces LCMC 18.280.040(1)-(2) | 2 spaces per unit LCMC 18.280.040(1)
for Single-family detached dwelling units (1 unit); Manufactured homes (1 unit) 3 spaces per unit LCMC 18.280.040(1); 18.185.130(1)(h)
for Cottage housing (4+ units)1 For uses not listed in Table 18.280.040, the review authority shall determine the required number of parking spaces by selecting the use with the most similar parking demand requirements. LCMC 18.280.040(3)
for Foster care homes (group living) |
| Maximum unit size | Not set LCMC 18.130.080 | 1.5 × 1,000 sq ft LCMC 18.185.060(1)(a)-(b)
for Cottage housing (4+ units)1 |
| Maximum lot size | No limit LCMC 18.130.080(2)(c)
for Duplexes (2 units) Not set LCMC 18.185.040
for Cottage housing (4+ units)1 | |
| Maximum building footprint | Not set LCMC 18.130.080 | 1,000 sq ft LCMC 18.185.060(1)(a)
for Cottage housing (4+ units)1 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit LCMC 18.247.050(2) | |
| Minimum lot size |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft LCMC 18.247.050(4)(a); 18.130.080(8) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Minimum parking | 1 space per unit LCMC 18.247.050(7) | |
| Maximum unit size |
|
|
| Attached to the main house | Not required LCMC 18.247.040(1)(c) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision LCMC 18.205.020(2) | A | up to 4 LCMC 18.40.010 | — | Minimum lot size 7,500 sq ft LCMC 18.130.080(2) Minimum lot width 60 ft LCMC 18.130.080(8) Minimum lot depth 90 ft LCMC 18.130.080(8) |
| Subdivision LCMC 18.210.020(2) | H | 5 or more LCMC 18.40.010 | — | Minimum lot size 7,500 sq ft LCMC 18.130.080(2) Minimum lot width 60 ft LCMC 18.130.080(8) Minimum lot depth 90 ft LCMC 18.130.080(8) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The cottage housing development is incorporated into a long subdivision plat of 10 or more lots plus the cottage units
- The cottage housing site abuts a critical area subject to review under Chapter 18.300 LCMC
- The critical area and buffer are at least 25 percent of the gross cottage housing site
- The critical area and buffer are protected by means of a covenant that runs with the land
- The LDR cottage housing development is connected to the LDR subdivision by dedicated public right-of-way
- A dwelling on one or both adjoining lots has a front yard setback less than the required depth for the district
- None of these is true:
- A dwelling on one or both adjoining lots has a front yard setback less than the required depth for the district
- All of these are true:
- Which LDR front setback reduction the single-family detached dwelling uses: none; at least five primary facade features with the garage set back (15 ft); or primary features plus four secondary features (12 ft) is primary_and_secondary_features
- The lot fronts an arterial street
- All of these are true:
- Which LDR front setback reduction the single-family detached dwelling uses: none; at least five primary facade features with the garage set back (15 ft); or primary features plus four secondary features (12 ft) is primary_features
- The lot fronts an arterial street
- All of these are true:
- Not all of these are true:
- Which LDR front setback reduction the single-family detached dwelling uses: none; at least five primary facade features with the garage set back (15 ft); or primary features plus four secondary features (12 ft) is one of primary_features, primary_and_secondary_features
- None of these is true:
- The lot fronts an arterial street
- A dwelling on one or both adjoining lots has a front yard setback less than the required depth for the district
- Not all of these are true:
- All of these are true:
- Not all of these are true:
- Which LDR front setback reduction the single-family detached dwelling uses: none; at least five primary facade features with the garage set back (15 ft); or primary features plus four secondary features (12 ft) is one of primary_features, primary_and_secondary_features
- None of these is true:
- The lot fronts an arterial street
- A dwelling on one or both adjoining lots has a front yard setback less than the required depth for the district
- Not all of these are true:
- The lot abuts the urban growth area boundary
- None of these is true:
- The lot abuts the urban growth area boundary
- Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is detached
- Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is not detached
- The ADU side lot line is a street side lot line
- None of these is true:
- The ADU side lot line is a street side lot line
- All of these are true:
- Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is detached
- The rear yard of the lot is adjacent to an alley
- Not all of these are true:
- Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is detached
- The rear yard of the lot is adjacent to an alley
- Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is not internal
- Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is internal