Sign in

TC · Transitional/Commercial

La Conner, WA · LCMC 15.36 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling units
HomeH1 ADU—
HomeH1 ADU—
HomeH1 ADU—
HomeH1 ADU—
—
Single-household dwelling
HomeH2 ADU—
————
Townhouse—
HomeH2 ADU—
HomeH2 ADU—
HomeH2 ADU—
—
Multihousehold dwelling——
HomeH2 ADU—
HomeH2 ADU—
—
Transitional housing————
HomeH ADU—
Housing for people with functional disabilities————
HomeH ADU—
Rest/convalescent/nursing homes————
HomeH ADU—
Adult family homes————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units
  • 26 units3 LCMC 15.36.030(2)(c)
  • 36 units4 LCMC 15.36.030(2)(c); 15.36.050
Minimum lot sizeNo limit LCMC 15.36.060(1)
Maximum residentsNot set LCMC 15.36.060
  • 6 persons5 LCMC 15.10.045
  • 8 persons6 LCMC 15.10.045
for Adult family homes (group living)

3. Building standards

StandardValueExceptions
Front setbackIn the transitional commercial area, setbacks should conform to match setbacks for structures in the First Street commercial HPD to preserve and enhance the storefront character of the street. LCMC 15.36.060(5)(a)
Total side setbacks
  • 0.25 × lot width ft7 LCMC 15.36.060(9)
  • Side yard setbacks outside of the shoreline area shall be consistent with the adjoining Commercial Zone.8 LCMC 15.36.060(9)
Maximum height30 ft LCMC 15.36.060(7)
Maximum lot coverage80% LCMC 15.36.060(3)
Maximum impervious surface80% LCMC 15.36.060(3)
Maximum floor area ratio2 LCMC 15.36.060(6)
Minimum parking
  • 1 space per unit9 LCMC 15.90.030(3)(c)(vii)
  • 2 spaces per unit10 LCMC 15.90.030(3)(c)(vii)
Hospitals, rest homes – One per three beds and one per staff. LCMC 15.90.030(2)(a)
for Rest/convalescent/nursing homes (group living)
Maximum lot sizeNo limit LCMC 15.36.060(2)
Minimum open space20% LCMC 15.36.060(4)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Binding site plan LCMC 15.55.080(1) A11
Maximum lots
Not set LCMC 15.55.040; 15.55.080; 15.55.100
—
Minimum lot size
No limit LCMC 15.36.060(1)
Binding site plan LCMC 15.55.080(1) H12
Maximum lots
Not set LCMC 15.55.040; 15.55.080; 15.55.100
—
Minimum lot size
No limit LCMC 15.36.060(1)
Lot line adjustment LCMC 15.125.050(1)-(2); 15.135.050(1) A
Maximum lots
which does not create any additional lot, tract, parcel, site, or division LCMC 15.10.645
—
Minimum lot size
no lot conforming to the minimum lot size requirement of the district is reduced below that minimum lot size LCMC 15.125.050(1)
Short subdivision LCMC 15.135.050(1) A up to 4 LCMC 15.10.1170 —
Minimum lot size
No limit LCMC 15.36.060(1)
Subdivision LCMC 15.135.050(1) H 5 or more LCMC 15.10.1165 —
Minimum lot size
No limit LCMC 15.36.060(1)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Residential units are mixed with commercial use in the development
  2. Lot is east of vacated Second Street, west of Third Street, south of Moore Street and north of Caledonia Street
  3. None of these is true:
    • The entire development includes all public amenities of the TC density bonus
  4. The entire development includes all public amenities of the TC density bonus
  5. None of these is true:
    • DSHS determines the home is of adequate size for up to eight adults
  6. DSHS determines the home is of adequate size for up to eight adults
  7. Lot is within the shoreline area
  8. None of these is true:
    • Lot is within the shoreline area
  9. Floor area of one unit is at most 1,200
  10. Floor area of one unit is more than 1,200
  11. None of these is true:
    • The binding site plan is for proposed residential uses
  12. The binding site plan is for proposed residential uses