HIGH DENSITY RESIDENTIAL · High-Density Residential District
Lacey, WA · LMC 16.18 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family detached structures | — | — | — | — | |
| Manufactured Home, Designated | — | — | — | — | |
| Duplex | — | — | — | — | |
| Townhouse | — | HomeA ADU— | HomeA ADU— | HomeA ADU— | — |
| Triplex | — | — | — | — | |
| Any residential use | — | — | — | — | |
| Cottage housing | — | — | — | Home✓ ADU— | — |
| Manufactured home park | — | — | — | — | |
| Housing for people with functional disabilities | — | — | — | — | |
| Co-living housing | — | — | — | — | |
| Nursing homes, convalescent care facilities | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set LMC 16.18.020(A)(1)
for Any residential use (4+ units); Townhouse (4+ units); Manufactured home park (4+ units) 60 units LMC 16.62.020(B); 16.62.030(O)
for Cottage housing (4+ units) 9 units LMC 16.61.040(A)
for Townhouse (4+ units) | |
| Minimum units | Not set LMC 16.18.020(A)(1) | 4 units LMC 16.62.030(O)
for Cottage housing (4+ units) 10 units LMC 16.61.040(A)
for Townhouse (4+ units) |
| Minimum lot size | Lot configurations shall be governed by density, setbacks, open space, and other requirements and guidelines herein. LMC 16.61.030(C)
for Townhouse (2, 3, 4+ units) Not set LMC 16.18.040(B)
for Any residential use (4+ units); Cottage housing (4+ units); Manufactured home park (4+ units); Co-living housing (group living) | |
| Minimum lot width | for Duplex (2 units); Triplex (3 units) Lot configurations shall be governed by density, setbacks, open space, and other requirements and guidelines herein. LMC 16.61.030(C)
for Townhouse (2, 3, 4+ units) Not set LMC 16.18.040(B)
for Any residential use (4+ units); Cottage housing (4+ units); Manufactured home park (4+ units); Co-living housing (group living) | |
| Minimum frontage | for Single-family detached structures (1 unit); Manufactured Home, Designated (1 unit); Housing for people with functional disabilities (group living); Nursing homes, convalescent care facilities (group living) Not set LMC 16.63.120
for Manufactured home park (4+ units) | |
| Minimum density | 12 units per acre LMC 16.18.020(A)(1) | Not set LMC 16.18.020(A)(1)
for Housing for people with functional disabilities (group living); Nursing homes, convalescent care facilities (group living) No limit LMC 16.56.020(B)
for Co-living housing (group living) |
| Minimum development size | Not set LMC 16.18.040 | 130,680 sq ft LMC 16.63.110
for Manufactured home park (4+ units) |
| Maximum residents | Not set LMC 16.18.040 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft LMC 16.18.040(A)(3) | 16 ft LMC 16.18.040(A)(3)
for Single-family detached structures (1 unit); Manufactured Home, Designated (1 unit); Duplex (2 units); Townhouse (2 units); Housing for people with functional disabilities (group living); Nursing homes, convalescent care facilities (group living) |
| Side setback | 5 ft LMC 16.18.040(A)(4) | |
| Total side setbacks | 10 ft LMC 16.18.040(A)(4) | Not set LMC 16.63.120
for Manufactured home park (4+ units) |
| Rear setback | 15 ft LMC 16.18.040(A)(6) | |
| Building separation | Not set LMC 16.18.040 | 20 ft LMC 16.61.030(J)
for Townhouse (2, 3, 4+ units) 10 ft LMC 16.62.030(K)
for Cottage housing (4+ units) |
| Maximum height | 80 ft LMC 16.18.040(C)(4) | |
| Maximum lot coverage | 50% LMC 16.18.040(C)(2) | Not set LMC 16.63.120
for Manufactured home park (4+ units) |
| Maximum impervious surface | 85% LMC 16.18.040(C)(3) | 50% LMC 16.63.120(E)
for Manufactured home park (4+ units) |
| Minimum parking | Not read LMC 16.18.050; 16.72.030(C) | The required number of parking spaces is an optional minimum of one space and a maximum of one and one-half spaces per dwelling. LMC 16.62.030(L)(1)
for Cottage housing (4+ units) |
| Maximum unit size | Not set LMC 16.18.040 | 1,200 sq ft LMC 16.62.030(C)
for Cottage housing (4+ units) 250 sq ft LMC 16.56.020(C)
for Co-living housing (group living) |
| Maximum lot size | Not set LMC 16.18.040 | 871,200 sq ft LMC 16.63.110
for Manufactured home park (4+ units) |
| Maximum building footprint | Not set LMC 16.18.040 | 800 sq ft LMC 16.62.030(C)
for Cottage housing (4+ units) |
| Minimum open space | 10% LMC 16.63.140
for Manufactured home park (4+ units) | |
| Maximum units per building | Not set LMC 16.18.040 | 6 units LMC 16.61.030(I)
for Townhouse (2, 3, 4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | the largest of 0, 3 − main dwelling units on the lot units LMC 16.52.020(A); 16.52.020(B) | the largest of 0, 4 − main dwelling units on the lot units LMC 16.52.020(A); 16.52.020(B)
for Single-family detached structures (1 unit)2; Manufactured Home, Designated (1 unit)2; Duplex (2 units)2; Triplex (3 units)2; Any residential use (4+ units)2; Manufactured home park (4+ units)2; Housing for people with functional disabilities (group living)2; Co-living housing (group living)2; Nursing homes, convalescent care facilities (group living)2 the largest of 0, 6 − main dwelling units on the lot units LMC 16.52.020(A); 16.52.020(B)
for Single-family detached structures (1 unit)3; Manufactured Home, Designated (1 unit)3; Duplex (2 units)3; Triplex (3 units)3; Any residential use (4+ units)3; Manufactured home park (4+ units)3; Housing for people with functional disabilities (group living)3; Co-living housing (group living)3; Nursing homes, convalescent care facilities (group living)3 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 16 ft LMC 16.52.040(A)(1); 16.18.040(A)(3) | |
| Side setback | 5 ft LMC 16.52.040(A)(1); 16.18.040(A)(4) | |
| Rear setback | ||
| Maximum height | 80 ft LMC 16.52.040(A)(1); 16.18.040(C)(4) | |
| Minimum parking | Not read LMC 16.52.040(D) | |
| Maximum unit size | 1,000 sq ft LMC 16.52.060(B) | |
| Attached to the main house | Not required LMC 16.52.060(A) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision LMC 15.08.090(B); 11.02.290 | A | 2 to 9 LMC 15.08.010; LMC 15.02.020(TT); 15.08.010 | — | |
| Subdivision LMC 15.10.020; 11.04.050 | H | 10 or more LMC 15.02.020(UU) | — | |
| Planned residential developments LMC 11.10.140; 11.10.030(C); 16.18.020(A)(1); 11.10.010(C) | H | — | Minimum parent area
Minimum density 12 units per acre LMC 11.10.120(B)(2); 16.18.020(A)(1) Area taken out for roads and utilities 20% LMC 11.10.120(B)(1) |
Minimum lot size No limit LMC 11.10.080 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Which units on the lot meet the affordability requirements of LMC 16.52.030: none, the fourth unit, or all units is none
- Which units on the lot meet the affordability requirements of LMC 16.52.030: none, the fourth unit, or all units is fourth_unit
- Which units on the lot meet the affordability requirements of LMC 16.52.030: none, the fourth unit, or all units is all_units
- Alleys are utilized for access to the lot
- None of these is true:
- Alleys are utilized for access to the lot
- The lot is an infill lot: a lot created from an underdeveloped lot or parcel
- All of these are true:
- Alleys are utilized for access to the lot
- The lot is an infill lot: a lot created from an underdeveloped lot or parcel
- None of these is true:
- The lot is an infill lot: a lot created from an underdeveloped lot or parcel
- Alleys are utilized for access to the lot
- None of these is true:
- The lot is an infill lot: a lot created from an underdeveloped lot or parcel
- All of these are true:
- The lot is an infill lot: a lot created from an underdeveloped lot or parcel
- Alleys are utilized for access to the lot
- All of these are true:
- The lot is an infill lot: a lot created from an underdeveloped lot or parcel
- Alleys are utilized for access to the lot
- Which kind of housing for people with functional disabilities: adult family home, residential care facility, or other (e.g. supported living arrangement) is adult_family_home
- Which kind of housing for people with functional disabilities: adult family home, residential care facility, or other (e.g. supported living arrangement) is residential_care_facility
- Which kind of housing for people with functional disabilities: adult family home, residential care facility, or other (e.g. supported living arrangement) is other
- The manufactured home space has rear load access
- None of these is true:
- The manufactured home space has rear load access
- The cottage has a minimum roof slope of six feet vertical to twelve feet horizontal
- None of these is true:
- The cottage has a minimum roof slope of six feet vertical to twelve feet horizontal
- All of these are true:
- The accessory dwelling unit is detached in a separate structure
- A lot line abuts a public alley that the public works department has not identified as part of the city's routine snow plow network
- Not all of these are true:
- The accessory dwelling unit is detached in a separate structure
- A lot line abuts a public alley that the public works department has not identified as part of the city's routine snow plow network
- The site is a numbered block of the original plat of the city or of a subdivision recorded before this title was adopted
- None of these is true:
- The site is a numbered block of the original plat of the city or of a subdivision recorded before this title was adopted