Sign in

ARC · Arterial Residential/Commercial

Lakewood, WA · LMC 18A.60.040 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached single-family, including manufactured homes
Home✓ ADU—
————
Use of existing buildings for residential purposes
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Two-family residential, attached or detached dwelling units. Duplex.—
Home✓ ADU—
———
Three-family residential, attached or detached dwelling units. Triplex.——
Home✓ ADU—
——
Townhouse——
Home✓ ADU—
Home✓ ADU—
—
Multifamily: Four-family residential, attached or detached dwelling units. Fourplex.———
Home✓ ADU—
—
Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex.———
Home✓ ADU—
—
Multifamily: Six-family residential, attached or detached dwelling units. Sixplex.———
Home✓ ADU—
—
Multifamily, seven or more residential units———
Home✓ ADU—
—
Co-living housing————
Home✓ ADU—
Foster care facility————
Home✓ ADU—
Assisted Living Facility————
Home✓ ADU—
Confidential Shelter————
Home✓ ADU—
Continuing Care Retirement Community————
Home✓ ADU—
Enhanced Services Facility————
HomeH ADU—
Nursing Home————
Home✓ ADU—
Permanent Supportive Housing————
HomeA ADU—
Rapid Re-Housing————
Home✓ ADU—
Transitional Housing————
HomeA ADU—
Type 1 Group Home, adult family home————
Home✓ ADU—
Type 2 Group Home————
Home✓ ADU—
Type 3 Group Home————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set LMC 18A.10.180
4 units LMC 18A.10.180
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units)
5 units LMC 18A.10.180
for Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units)
6 units LMC 18A.10.180
for Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units)
Minimum units4 units LMC 18A.10.180
5 units LMC 18A.10.180
for Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units)
6 units LMC 18A.10.180
for Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units)
7 units LMC 18A.10.180
for Multifamily, seven or more residential units (4+ units)
3 units LMC 18A.10.180
for Townhouse (4+ units)
Not set LMC 18A.10.180
for Use of existing buildings for residential purposes (4+ units)1
Minimum lot size5,000 + (2,750 × (main dwelling units on the lot − 1)) sq ft LMC 18A.60.040(A)
Minimum lot width50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft2 LMC 18A.60.090(B)(9)(b)
  • 50 ft3 LMC 18A.60.090(A)(5)
Maximum densityNot set LMC 18A.60.040(A)
15 units per acre, a fraction of 0.5 or more rounds up LMC 18A.60.040(A); 18A.60.110(G)
for Detached single-family, including manufactured homes (1 unit); Two-family residential, attached or detached dwelling units. Duplex. (2 units); Three-family residential, attached or detached dwelling units. Triplex. (3 units); Townhouse (3 units)
15 × 1.5 units per acre, a fraction of 0.5 or more rounds up LMC 18A.60.040(A); 18A.40.110(B)(15)(a); 18A.60.110(G)
for Use of existing buildings for residential purposes (1, 2, 3, 4+ units)1
  • 15 units per acre, a fraction of 0.5 or more rounds up4 LMC 18A.60.040(A); 18A.60.110(G)
  • 15 × 1.25 units per acre, a fraction of 0.5 or more rounds up5 LMC 18A.60.040(A); 18A.60.110(G); 18A.90.050(A)
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units); Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units); Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units); Multifamily, seven or more residential units (4+ units); Townhouse (4+ units)
Maximum residentsNot set LMC 18A.10.180
  • 8 persons6 LMC 18A.10.180
  • 6 persons7 LMC 18A.10.180
  • Not set8 LMC 18A.10.180
for Type 1 Group Home, adult family home (group living)
Maximum sleeping unitsNot set LMC 18A.10.180
4 × ((15 × lot area) ÷ 43,560, rounded) sleeping units LMC 18A.60.040(A); 18A.40.110(B)(14)(d)
for Co-living housing (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 10 ft2 LMC 18A.60.090(B)(9)
  • 0 ft3 LMC 18A.60.040(A)
Side setback
  • 10 ft2 LMC 18A.60.090(B)(9)
  • 0 ft3 LMC 18A.60.040(A)
Street side setback0 ft LMC 18A.60.040(A); 18A.60.090(B)(7)
Rear setback
  • 10 ft2 LMC 18A.60.090(B)(9)
  • 0 ft3 LMC 18A.60.040(A)
Maximum height40 ft LMC 18A.60.040(A)
Maximum lot coverage50% LMC 18A.60.040(A)
Maximum impervious surface60% LMC 18A.60.040(A)
Minimum parkingThe requirements for any use not listed herein shall be those of the listed use most similar to the unlisted use. When similarity is not apparent, the Director shall determine the minimum and maximum for the unlisted use. LMC 18A.80.030(A)
2 spaces per unit LMC 18A.80.030(F)
for Detached single-family, including manufactured homes (1 unit)
Sufficient existing parking must be retained to satisfy the number required for existing residential units and nonresidential uses that remain after the new residential units are added; LMC 18A.40.110(B)(15)(b); 18A.40.110(B)(15)(f)
for Use of existing buildings for residential purposes (1, 2, 3, 4+ units)1
  • 0 spaces per unit9 LMC 18A.80.030(F); 18A.80.030(G)(5)
  • 1 space per unit10 LMC 18A.80.030(F)
  • 2 spaces per unit11 LMC 18A.80.030(F)
for Two-family residential, attached or detached dwelling units. Duplex. (2 units); Three-family residential, attached or detached dwelling units. Triplex. (3 units); Townhouse (3 units)
  • 0 spaces per unit9 LMC 18A.80.030(F); 18A.80.030(G)(5)
  • 1 space per unit12 LMC 18A.80.030(F)
  • 1 space per unit13 LMC 18A.80.030(F)
  • 1.25 spaces per unit14 LMC 18A.80.030(F)
  • 1.5 spaces per unit15 LMC 18A.80.030(F)
  • the smallest of 2, the largest of 0.75, bedrooms in one unit spaces per unit16 LMC 18A.80.030(G)(6)(a)
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units); Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units); Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units); Townhouse (4+ units)
  • 1 space per unit17 LMC 18A.80.030(F)
  • 1.25 spaces per unit18 LMC 18A.80.030(F)
  • 1.5 spaces per unit19 LMC 18A.80.030(F)
  • 0.75 spaces per unit20 LMC 18A.80.030(F)
  • 1 space per unit21 LMC 18A.80.030(F)
  • 1.5 spaces per unit22 LMC 18A.80.030(F)
  • the smallest of 2, the largest of 0.75, bedrooms in one unit spaces per unit16 LMC 18A.80.030(G)(6)(a)
for Multifamily, seven or more residential units (4+ units)
  • 0 spaces per sleeping unit23 LMC 18A.40.110(B)(14)(g); 18A.40.110(B)(14)(g)(i)
  • 0.25 spaces per sleeping unit24 LMC 18A.40.110(B)(14)(g)(ii)
for Co-living housing (group living)
0.5 spaces per bed LMC 18A.80.030(F)
for Nursing Home (group living)
The minimum number of off-street parking spaces required for each facility will be determined by the Director through the approval process per Chapter 18A.80, 18B.600, or 18C.600 LMC and taking into consideration factors such as the potential number of residents, site constraints, and impact on the surrounding neighborhood. LMC 18A.40.120(C)(5)(b)(i)(b)(iii)
for Permanent Supportive Housing (group living); Transitional Housing (group living)
Maximum unit sizeNot set LMC 18A.60.040(A)
300 sq ft LMC 18A.40.110(B)(14)(a)(i)
for Co-living housing (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision LMC 17.22.070(A) A up to 9 LMC 17.02.035 —
Minimum lot size
5,000 sq ft LMC 18A.60.040(A)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft2 LMC 18A.60.090(B)(9)(b)
  • 50 ft3 LMC 18A.60.090(A)(5)
Subdivision LMC 17.14.010 H 10 or more LMC 17.02.035; 17.10.020(A) —
Minimum lot size
5,000 sq ft LMC 18A.60.040(A)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft2 LMC 18A.60.090(B)(9)(b)
  • 50 ft3 LMC 18A.60.090(A)(5)
Plats with private streets LMC 17.26.010; 17.26.020; 17.22.070(A) A up to 9 LMC 17.26.020; 17.02.035 —
Minimum lot size
5,000 sq ft LMC 18A.60.040(A)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft2 LMC 18A.60.090(B)(9)(b)
  • 50 ft3 LMC 18A.60.090(A)(5)
Plats with private streets LMC 17.26.010; 17.26.020; 17.14.010 H 10 or more LMC 17.26.020; 17.02.035 —
Minimum lot size
5,000 sq ft LMC 18A.60.040(A)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft2 LMC 18A.60.090(B)(9)(b)
  • 50 ft3 LMC 18A.60.090(A)(5)
Residential condominium binding site plan LMC 17.34.010; 17.34.030; 17.34.030(D) A25 — —
Minimum lot size
Not set LMC 17.34.030
Unit lot subdivision LMC 17.24.040(B); 17.22.070(A); 17.24.020(A)-(B) A26 up to 9 LMC 17.24.040(B)
Maximum parent area
87,120 sq ft LMC 17.24.020(D); 17.24.020(G); 17.24.030(D)
Minimum units
2 units LMC 17.24.020(D)
Minimum lot size
No limit LMC 17.24.030(B)
Unit lot subdivision LMC 17.24.040(A); 17.14.010; 17.24.020(A)-(B) H27 10 or more LMC 17.24.040(A); 17.02.035
Maximum parent area
87,120 sq ft LMC 17.24.020(D); 17.24.020(G); 17.24.030(D)
Minimum units
2 units LMC 17.24.020(D)
Minimum lot size
No limit LMC 17.24.030(B)
Binding site plan LMC 17.30.045(A) A 2 or more LMC 17.30.020(A) —
Minimum lot size
5,000 sq ft LMC 18A.60.040(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The building is an existing building (certificate of occupancy at least 3 years before the application)
    None of these is true:
    • The existing building has ground floor commercial or retail along a major pedestrian corridor
  2. Lot is a flag lot
  3. None of these is true:
    • Lot is a flag lot
  4. None of these is true:
    • The project uses an inclusionary or religious-organization density bonus of Chapter 18A.90 LMC
  5. The project uses an inclusionary or religious-organization density bonus of Chapter 18A.90 LMC
  6. All of these are true:
    • The Type 1 group home is an adult family home
    • The adult family home has department approval under RCW 70.128.066 to serve up to eight adults
  7. All of these are true:
    • The Type 1 group home is an adult family home
    None of these is true:
    • The adult family home has department approval under RCW 70.128.066 to serve up to eight adults
  8. None of these is true:
    • The Type 1 group home is an adult family home
  9. The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
  10. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
  11. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
  12. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  13. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one unit is 0
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  14. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one unit is 1
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  15. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one unit is at least 2
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  16. All of these are true:
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
  17. All of these are true:
    • Bedrooms in one unit is 0
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  18. All of these are true:
    • Bedrooms in one unit is 1
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  19. All of these are true:
    • Bedrooms in one unit is at least 2
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  20. All of these are true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • Bedrooms in one unit is 0
  21. All of these are true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • Bedrooms in one unit is 1
  22. All of these are true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • Bedrooms in one unit is at least 2
  23. The lot is within 1/2 mile walking distance of a major transit stop as defined in RCW 36.70A.535
  24. None of these is true:
    • The lot is within 1/2 mile walking distance of a major transit stop as defined in RCW 36.70A.535
  25. All of these are true:
    • The project is a residential condominium that proposes to subdivide land into separate lots
    • A building permit has been issued for the entire project
  26. None of these is true:
    • The unit lot subdivision creates 10 or more lots
  27. The unit lot subdivision creates 10 or more lots