Sign in

C2 · Commercial 2

Lakewood, WA · LMC 18A.60.040 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Live/work and work/live units
HomeH ADU—
HomeH ADU—
HomeH ADU—
HomeH ADU—
—
Use of existing buildings for residential purposes
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Assisted Living Facility————
Home✓ ADU—
Continuing Care Retirement Community————
Home✓ ADU—
Emergency Housing————
HomeA2 ADU—
Emergency Shelter————
HomeA2 ADU—
Enhanced Services Facility————
HomeH ADU—
Nursing Home————
Home✓ ADU—
Permanent Supportive Housing————
HomeA ADU—
Transitional Housing————
HomeA ADU—
Type 4 Group Home————
HomeH3 ADU—
Type 5 Group Home————
HomeH3 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit LMC 18A.60.040(A)
Minimum lot width50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft4 LMC 18A.60.090(B)(9)(b)
  • 50 ft5 LMC 18A.60.090(A)(5)

3. Building standards

StandardValueExceptions
Front setback
  • 10 ft4 LMC 18A.60.090(B)(9)
  • 0 ft5 LMC 18A.60.040(A)
Side setback
  • 10 ft4 LMC 18A.60.090(B)(9)
  • 0 ft5 LMC 18A.60.040(A)
Street side setback0 ft LMC 18A.60.040(A); 18A.60.090(B)(7)
Rear setback
  • 10 ft4 LMC 18A.60.090(B)(9)
  • 0 ft5 LMC 18A.60.040(A)
Maximum height
  • 40 ft6 LMC 18A.60.100(B)
  • 60 ft7 LMC 18A.60.040(A)
60 ft LMC 18A.60.040(A)
for Use of existing buildings for residential purposes (1, 2, 3 units)1
Maximum lot coverage100% LMC 18A.60.040(A)
Maximum impervious surface100% LMC 18A.60.040(A)
Minimum parkingThe requirements for any use not listed herein shall be those of the listed use most similar to the unlisted use. When similarity is not apparent, the Director shall determine the minimum and maximum for the unlisted use. LMC 18A.80.030(A)
For conditional uses, as identified and described in Chapter 18A.20 LMC, Article II, the parking requirement shall be as provided in that chapter or as determined by the Hearing Examiner. LMC 18A.80.030(B)
for Live/work and work/live units (1, 2, 3, 4+ units)
Sufficient existing parking must be retained to satisfy the number required for existing residential units and nonresidential uses that remain after the new residential units are added; LMC 18A.40.110(B)(15)(b); 18A.40.110(B)(15)(f)
for Use of existing buildings for residential purposes (1, 2, 3, 4+ units)1
The minimum number of off-street parking spaces required for each facility will be determined by the Director through the approval process per Chapter 18A.80, 18B.600, or 18C.600 LMC and taking into consideration factors such as the potential number of residents, site constraints, and impact on the surrounding neighborhood. LMC 18A.40.120(C)(5)(b)(i)(b)(iii)
for Emergency Housing (group living)2; Emergency Shelter (group living)2; Permanent Supportive Housing (group living); Transitional Housing (group living)
0.5 spaces per bed LMC 18A.80.030(F)
for Nursing Home (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision LMC 17.22.070(A) A up to 9 LMC 17.02.035 —
Minimum lot size
No limit LMC 18A.60.040(A)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft4 LMC 18A.60.090(B)(9)(b)
  • 50 ft5 LMC 18A.60.090(A)(5)
Subdivision LMC 17.14.010 H 10 or more LMC 17.02.035; 17.10.020(A) —
Minimum lot size
No limit LMC 18A.60.040(A)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft4 LMC 18A.60.090(B)(9)(b)
  • 50 ft5 LMC 18A.60.090(A)(5)
Plats with private streets LMC 17.26.010; 17.26.020; 17.22.070(A) A up to 9 LMC 17.26.020; 17.02.035 —
Minimum lot size
No limit LMC 18A.60.040(A)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft4 LMC 18A.60.090(B)(9)(b)
  • 50 ft5 LMC 18A.60.090(A)(5)
Plats with private streets LMC 17.26.010; 17.26.020; 17.14.010 H 10 or more LMC 17.26.020; 17.02.035 —
Minimum lot size
No limit LMC 18A.60.040(A)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft4 LMC 18A.60.090(B)(9)(b)
  • 50 ft5 LMC 18A.60.090(A)(5)
Residential condominium binding site plan LMC 17.34.010; 17.34.030; 17.34.030(D) A8 — —
Minimum lot size
Not set LMC 17.34.030
Unit lot subdivision LMC 17.24.040(B); 17.22.070(A); 17.24.020(A)-(B) A9 up to 9 LMC 17.24.040(B)
Maximum parent area
87,120 sq ft LMC 17.24.020(D); 17.24.020(G); 17.24.030(D)
Minimum units
2 units LMC 17.24.020(D)
Minimum lot size
No limit LMC 17.24.030(B)
Unit lot subdivision LMC 17.24.040(A); 17.14.010; 17.24.020(A)-(B) H10 10 or more LMC 17.24.040(A); 17.02.035
Maximum parent area
87,120 sq ft LMC 17.24.020(D); 17.24.020(G); 17.24.030(D)
Minimum units
2 units LMC 17.24.020(D)
Minimum lot size
No limit LMC 17.24.030(B)
Binding site plan LMC 17.30.045(A) A 2 or more LMC 17.30.020(A) —
Minimum lot size
No limit LMC 18A.60.040(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The building is an existing building (certificate of occupancy at least 3 years before the application)
    None of these is true:
    • The existing building has ground floor commercial or retail along a major pedestrian corridor
  2. Any of these is true:
    • None of these is true:
      • Another property within an 880 foot radius has emergency housing or an emergency shelter
    • The facility is sponsored by the same governmental, religious, or not-for-profit agency as the nearby emergency housing or shelter
  3. None of these is true:
    • The lot is within the Lakewood Station District Subarea (LSDS)
  4. Lot is a flag lot
  5. None of these is true:
    • Lot is a flag lot
  6. The portion of the building is within a building transition area along a property line abutting an R1, R2, R3, R4, MR1 or MR2 zone
  7. None of these is true:
    • The portion of the building is within a building transition area along a property line abutting an R1, R2, R3, R4, MR1 or MR2 zone
  8. All of these are true:
    • The project is a residential condominium that proposes to subdivide land into separate lots
    • A building permit has been issued for the entire project
  9. None of these is true:
    • The unit lot subdivision creates 10 or more lots
  10. The unit lot subdivision creates 10 or more lots