MF2 · Multifamily 2
Lakewood, WA · LMC 18A.60.030 · Official code
By right: 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Use of existing buildings for residential purposes | — | ||||
| Townhouse | — | — | — | ||
| Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. | — | — | — | — | |
| Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. | — | — | — | — | |
| Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. | — | — | — | — | |
| Multifamily, seven or more residential units | — | — | — | — | |
| Mobile home parks | — | — | — | — | |
| Specialized senior housing | — | — | — | — | |
| Co-living housing | — | — | — | — | Home✓ ADU— |
| Co-housing (dormitories, fraternities and sororities) | — | — | — | — | |
| Foster care facility | — | — | — | — | |
| Assisted Living Facility | — | — | — | — | Home✓ ADU— |
| Confidential Shelter | — | — | — | — | Home✓ ADU— |
| Continuing Care Retirement Community | — | — | — | — | Home✓ ADU— |
| Hospice Care Center | — | — | — | — | Home✓ ADU— |
| Nursing Home | — | — | — | — | Home✓ ADU— |
| Permanent Supportive Housing | — | — | — | — | HomeA ADU— |
| Rapid Re-Housing | — | — | — | — | Home✓ ADU— |
| Transitional Housing | — | — | — | — | HomeA ADU— |
| Type 1 Group Home, adult family home | — | — | — | — | |
| Type 2 Group Home | — | — | — | — | |
| Type 3 Group Home | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set LMC 18A.10.180 | 4 units LMC 18A.10.180
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units) 5 units LMC 18A.10.180
for Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units) 6 units LMC 18A.10.180
for Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units) |
| Minimum units | 2 units LMC 18A.10.180 | 4 units LMC 18A.10.180
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units) 5 units LMC 18A.10.180
for Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units) 6 units LMC 18A.10.180
for Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units) 7 units LMC 18A.10.180
for Multifamily, seven or more residential units (4+ units) 3 units LMC 18A.10.180
for Townhouse (4+ units) Not set LMC 18A.10.180
for Use of existing buildings for residential purposes (4+ units)1 |
| Minimum lot size | No limit LMC 18A.60.030(A) | |
| Minimum lot width | 50 ft LMC 18A.60.090(A)(4) | |
| Minimum frontage | ||
| Maximum density | Not set LMC 18A.60.030(A) | 35 × 1.5 units per acre, a fraction of 0.5 or more rounds up LMC 18A.60.030(A); 18A.40.110(B)(15)(a); 18A.60.110(G)
for Use of existing buildings for residential purposes (1, 2, 3, 4+ units)1 35 units per acre, a fraction of 0.5 or more rounds up LMC 18A.60.030(A); 18A.60.110(G)
for Townhouse (3 units); Permanent Supportive Housing (group living); Transitional Housing (group living) for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units); Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units); Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units); Multifamily, seven or more residential units (4+ units); Townhouse (4+ units); Mobile home parks (4+ units); Specialized senior housing (4+ units) |
| Minimum development size | Not set LMC 18A.60.030(A) | 130,680 sq ft LMC 18A.40.110(C)(5); 18A.40.110(C)(2)(b)
for Mobile home parks (4+ units) |
| Maximum residents | Not set LMC 18A.10.180 | |
| Maximum sleeping units | Not set LMC 18A.10.180 | 4 × ((35 × lot area) ÷ 43,560, rounded) sleeping units LMC 18A.60.030(A); 18A.40.110(B)(14)(d)
for Co-living housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Street side setback | ||
| Rear setback | ||
| Maximum height | 65 ft LMC 18A.60.030(A)
| |
| Maximum lot coverage | 60% LMC 18A.60.030(A) | 45% LMC 18A.60.030(A); 18A.60.030(B)(2)(d); 18A.60.030(B)(2)(c)
50% LMC 18A.60.030(A); 18A.60.030(B)(2)(d); 18A.60.030(B)(2)(b)
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units); Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units) 55% LMC 18A.60.030(A); 18A.60.030(B)(2)(d); 18A.60.030(B)(2)(a)
for Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units) for Townhouse (4+ units); Mobile home parks (4+ units); Use of existing buildings for residential purposes (4+ units)1; Specialized senior housing (4+ units) |
| Maximum impervious surface | 70% LMC 18A.60.030(A) | |
| Minimum parking | The requirements for any use not listed herein shall be those of the listed use most similar to the unlisted use. When similarity is not apparent, the Director shall determine the minimum and maximum for the unlisted use. LMC 18A.80.030(A) | Sufficient existing parking must be retained to satisfy the number required for existing residential units and nonresidential uses that remain after the new residential units are added; LMC 18A.40.110(B)(15)(b); 18A.40.110(B)(15)(f)
for Use of existing buildings for residential purposes (1, 2, 3, 4+ units)1 for Townhouse (3 units)
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units); Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units); Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units); Townhouse (4+ units)
for Multifamily, seven or more residential units (4+ units) 1.5 spaces per unit LMC 18A.80.030(F); 18A.40.110(C)(7)
for Mobile home parks (4+ units) for Specialized senior housing (4+ units) for Co-living housing (group living) 0.5 spaces per bed LMC 18A.80.030(F)
for Nursing Home (group living) The minimum number of off-street parking spaces required for each facility will be determined by the Director through the approval process per Chapter 18A.80, 18B.600, or 18C.600 LMC and taking into consideration factors such as the potential number of residents, site constraints, and impact on the surrounding neighborhood. LMC 18A.40.120(C)(5)(b)(i)(b)(iii)
for Permanent Supportive Housing (group living); Transitional Housing (group living) |
| Maximum unit size | Not set LMC 18A.60.030(A) | 300 sq ft LMC 18A.40.110(B)(14)(a)(i)
for Co-living housing (group living) |
| Maximum lot size | Not set LMC 18A.60.030(A) | 871,200 sq ft LMC 18A.40.110(C)(5)
for Mobile home parks (4+ units) |
| Minimum open space | Not set LMC 18A.60.030(A) | 10% LMC 18A.40.110(C)(8)
for Mobile home parks (4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units LMC 18A.40.110(B)(1)(a); 18A.40.110(B)(1)(d) | 1 unit LMC 18A.40.110(B)(1)(b)
for Use of existing buildings for residential purposes (1, 2, 3, 4+ units)3; Townhouse (3, 4+ units)5; Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units)5; Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units)5; Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units)5; Multifamily, seven or more residential units (4+ units)5; Mobile home parks (4+ units)5; Specialized senior housing (4+ units)5; Foster care facility (group living)5; Type 1 Group Home, adult family home (group living)5; Type 2 Group Home (group living)5 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | 65 ft LMC 18A.60.030(A) | |
| Minimum parking | ||
| Maximum unit size | ||
| Attached to the main house | Not required LMC 18A.40.110(B)(1)(c) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision LMC 17.22.070(A) | A | up to 9 LMC 17.02.035 | — | Minimum lot size No limit LMC 18A.60.030(A) Minimum lot width 50 ft LMC 18A.60.090(A)(4) |
| Subdivision LMC 17.14.010 | H | 10 or more LMC 17.02.035; 17.10.020(A) | — | Minimum lot size No limit LMC 18A.60.030(A) Minimum lot width 50 ft LMC 18A.60.090(A)(4) |
| Plats with private streets LMC 17.26.010; 17.26.020; 17.22.070(A) | A | up to 9 LMC 17.26.020; 17.02.035 | — | Minimum lot size No limit LMC 18A.60.030(A) Minimum lot width 50 ft LMC 18A.60.090(A)(4) |
| Plats with private streets LMC 17.26.010; 17.26.020; 17.14.010 | H | 10 or more LMC 17.26.020; 17.02.035 | — | Minimum lot size No limit LMC 18A.60.030(A) Minimum lot width 50 ft LMC 18A.60.090(A)(4) |
| Residential condominium binding site plan LMC 17.34.010; 17.34.030; 17.34.030(D) | A47 | — | — | Minimum lot size Not set LMC 17.34.030 |
| Unit lot subdivision LMC 17.24.040(B); 17.22.070(A); 17.24.020(A)-(B) | A48 | up to 9 LMC 17.24.040(B) | Maximum parent area 87,120 sq ft LMC 17.24.020(D); 17.24.020(G); 17.24.030(D) Minimum units 2 units LMC 17.24.020(D) |
Minimum lot size No limit LMC 17.24.030(B) |
| Unit lot subdivision LMC 17.24.040(A); 17.14.010; 17.24.020(A)-(B) | H49 | 10 or more LMC 17.24.040(A); 17.02.035 | Maximum parent area 87,120 sq ft LMC 17.24.020(D); 17.24.020(G); 17.24.030(D) Minimum units 2 units LMC 17.24.020(D) |
Minimum lot size No limit LMC 17.24.030(B) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The building is an existing building (certificate of occupancy at least 3 years before the application)
- The existing building has ground floor commercial or retail along a major pedestrian corridor
- All of these are true:
- The building is an existing building (certificate of occupancy at least 3 years before the application)
- The existing building has ground floor commercial or retail along a major pedestrian corridor
- The lot is designated with critical areas or their buffers
- All of these are true:
- The building is an existing building (certificate of occupancy at least 3 years before the application)
- The lot is designated with critical areas or their buffers
- The existing building has ground floor commercial or retail along a major pedestrian corridor
- None of these is true:
- The lot is designated with critical areas or their buffers
- The lot is designated with critical areas or their buffers
- The dormitory, fraternity or sorority is accessory to a public or private educational institution or church
- Lot is a flag lot
- None of these is true:
- Lot is a flag lot
- None of these is true:
- The project uses an inclusionary or religious-organization density bonus of Chapter 18A.90 LMC
- The project uses an inclusionary or religious-organization density bonus of Chapter 18A.90 LMC
- All of these are true:
- The Type 1 group home is an adult family home
- The adult family home has department approval under RCW 70.128.066 to serve up to eight adults
- All of these are true:
- The Type 1 group home is an adult family home
- The adult family home has department approval under RCW 70.128.066 to serve up to eight adults
- None of these is true:
- The Type 1 group home is an adult family home
- All of these are true:
- Lot is a flag lot
- The lot line abuts a principal arterial or state highway
- All of these are true:
- Lot is a flag lot
- The lot line abuts a principal arterial or state highway
- All of these are true:
- The lot line abuts a principal arterial or state highway
- Lot is a flag lot
- None of these is true:
- Lot is a flag lot
- The lot line abuts a principal arterial or state highway
- All of these are true:
- The rear yard abuts an alley
- Lot is a flag lot
- None of these is true:
- Lot is a flag lot
- The rear yard abuts an alley
- The portion of the building is within a building transition area along a property line abutting an R1, R2, R3, R4, MR1 or MR2 zone
- None of these is true:
- The portion of the building is within a building transition area along a property line abutting an R1, R2, R3, R4, MR1 or MR2 zone
- Main dwelling units on the lot is at most 5
- Main dwelling units on the lot is 6
- Main dwelling units on the lot is at least 7
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- All of these are true:
- Lot area is at most 6,000 sf
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- All of these are true:
- Lot area is more than 6,000 sf
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- All of these are true:
- Lot area is at most 6,000 sf
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- Lot area is more than 6,000 sf
- Bedrooms in one unit is 0
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- Lot area is more than 6,000 sf
- Bedrooms in one unit is 1
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- Lot area is more than 6,000 sf
- Bedrooms in one unit is at least 2
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- All of these are true:
- Bedrooms in one unit is 0
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- Bedrooms in one unit is 1
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- Bedrooms in one unit is at least 2
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- Bedrooms in one unit is 0
- All of these are true:
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- Bedrooms in one unit is 1
- All of these are true:
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- Bedrooms in one unit is at least 2
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- None of these is true:
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- The lot is within 1/2 mile walking distance of a major transit stop as defined in RCW 36.70A.535
- None of these is true:
- The lot is within 1/2 mile walking distance of a major transit stop as defined in RCW 36.70A.535
- All of these are true:
- The lot is within 1/4 mile of a Pierce Transit bus route or 1/2 mile of the Sound Transit Lakewood Station, commuter rail or bus rapid transit stop, or other transit stop providing fixed route service at intervals of at least 15 minutes for at least 5 hours during weekday peak hours
- The Director determines there is adequate street capacity: access to street parking capacity, no physical space impediments, and no other reasons that on-street parking is infeasible for the ADU
- Not all of these are true:
- The lot is within 1/4 mile of a Pierce Transit bus route or 1/2 mile of the Sound Transit Lakewood Station, commuter rail or bus rapid transit stop, or other transit stop providing fixed route service at intervals of at least 15 minutes for at least 5 hours during weekday peak hours
- The Director determines there is adequate street capacity: access to street parking capacity, no physical space impediments, and no other reasons that on-street parking is infeasible for the ADU
- The ADU is attached ADU contained within or attached to an existing single-family structure
- None of these is true:
- The ADU is attached ADU contained within or attached to an existing single-family structure
- All of these are true:
- The project is a residential condominium that proposes to subdivide land into separate lots
- A building permit has been issued for the entire project
- None of these is true:
- The unit lot subdivision creates 10 or more lots
- The unit lot subdivision creates 10 or more lots