TOC · Transit-Oriented Commercial
Lakewood, WA · LMC 18C.200 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached single-family, including manufactured homes | — | — | — | — | |
| Live/work and work/live units | — | ||||
| Use of existing buildings for residential purposes | — | ||||
| Two-family residential, attached or detached dwelling units. Duplex. | — | — | — | — | |
| Stacked flats | — | — | |||
| Cottage housing | — | — | |||
| Courtyard apartments | — | — | |||
| Rowhouses | — | — | |||
| Three-family residential, attached or detached dwelling units. Triplex. | — | — | — | — | |
| Townhouse | — | — | — | ||
| Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. | — | — | — | — | |
| Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. | — | — | — | — | |
| Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. | — | — | — | — | |
| Multifamily, seven or more residential units | — | — | — | — | |
| Mixed use | — | — | — | — | |
| Mobile home parks | — | — | — | — | |
| Specialized senior housing | — | — | — | — | |
| Boarding house | — | — | — | — | HomeH ADU— |
| Co-living housing | — | — | — | — | Home✓ ADU— |
| Co-housing (dormitories, fraternities and sororities) | — | — | — | — | |
| Foster care facility | — | — | — | — | |
| Assisted Living Facility | — | — | — | — | Home✓ ADU— |
| Confidential Shelter | — | — | — | — | Home✓ ADU— |
| Continuing Care Retirement Community | — | — | — | — | Home✓ ADU— |
| Emergency Housing | — | — | — | — | |
| Emergency Shelter | — | — | — | — | |
| Enhanced Services Facility | — | — | — | — | HomeH ADU— |
| Hospice Care Center | — | — | — | — | Home✓ ADU— |
| Nursing Home | — | — | — | — | Home✓ ADU— |
| Permanent Supportive Housing | — | — | — | — | HomeA ADU— |
| Rapid Re-Housing | — | — | — | — | Home✓ ADU— |
| Transitional Housing | — | — | — | — | HomeA ADU— |
| Type 1 Group Home, adult family home | — | — | — | — | |
| Type 2 Group Home | — | — | — | — | |
| Type 3 Group Home | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set LMC 18A.10.180 | 4 units LMC 18A.10.180
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units) 5 units LMC 18A.10.180
for Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units) 6 units LMC 18A.10.180
for Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units) |
| Minimum units | Not set LMC 18A.10.180 | 4 units LMC 18A.10.180
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units) 5 units LMC 18A.10.180
for Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units) 6 units LMC 18A.10.180
for Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units) 7 units LMC 18A.10.180
for Multifamily, seven or more residential units (4+ units) 3 units LMC 18A.10.180
for Townhouse (4+ units) 2 units LMC 18A.10.180
for Mobile home parks (4+ units); Specialized senior housing (4+ units) |
| Minimum lot size | No limit LMC 18C.200.230(B) | |
| Minimum lot width | 50 ft LMC 18A.60.090(A)(4) | |
| Minimum frontage | ||
| Maximum density | Not set LMC 18A.60.040(A) | 80 units per acre, a fraction of 0.5 or more rounds up LMC 18A.60.040(A); 18A.60.110(G); 18C.200.230(A)
for Detached single-family, including manufactured homes (1 unit); Live/work and work/live units (1, 2, 3 units); Two-family residential, attached or detached dwelling units. Duplex. (2 units); Stacked flats (2, 3 units); Cottage housing (2, 3 units); Courtyard apartments (2, 3 units); Rowhouses (2, 3 units); Three-family residential, attached or detached dwelling units. Triplex. (3 units); Townhouse (3 units) 80 × 1.5 units per acre, a fraction of 0.5 or more rounds up LMC 18A.60.040(A); 18A.40.110(B)(15)(a); 18A.60.110(G)
for Use of existing buildings for residential purposes (1, 2, 3, 4+ units)3 for Live/work and work/live units (4+ units); Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units); Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units); Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units); Multifamily, seven or more residential units (4+ units); Townhouse (4+ units); Stacked flats (4+ units); Cottage housing (4+ units); Courtyard apartments (4+ units); Mixed use (4+ units); Mobile home parks (4+ units); Specialized senior housing (4+ units); Rowhouses (4+ units) |
| Minimum development size | Not set LMC 18A.60.040(A) | 130,680 sq ft LMC 18A.40.110(C)(5); 18A.40.110(C)(2)(b)
for Mobile home parks (4+ units) |
| Maximum residents | Not set LMC 18A.10.180 | |
| Maximum sleeping units | Not set LMC 18A.10.180 | 4 × ((80 × lot area) ÷ 43,560, rounded) sleeping units LMC 18A.60.040(A); 18A.40.110(B)(14)(d)
for Co-living housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | The minimum distance setbacks for the Station District shall be determined by frontage type in Chapter 18C.400 LMC, except where increased setbacks due to building/fire code requirements apply. LMC 18C.200.230(D); 18C.400.410(A) | |
| Maximum front setback | The maximum setback shall be up to 10 feet where the Department of Planning a Public Works (PPW) Director has determined property may be needed to accommodate the City’s planned right-of-way at full build-out. Otherwise, the maximum setback is zero (0) feet. LMC 18C.400.410(A)(1) | |
| Side setback | 0 ft LMC 18A.60.040(A) | |
| Street side setback | The minimum distance setbacks for the Station District shall be determined by frontage type in Chapter 18C.400 LMC, except where increased setbacks due to building/fire code requirements apply. LMC 18C.200.230(D); 18C.400.410(A) | |
| Rear setback | 0 ft LMC 18A.60.040(A) | |
| Maximum height | 90 ft LMC 18A.60.040(A); 18C.200.230(E) | |
| Maximum stories | Not set LMC 18A.60.040(A) | 3 stories LMC 18A.10.180
for Stacked flats (2, 3, 4+ units) |
| Maximum lot coverage | No limit LMC 18C.200.230(C) | |
| Maximum impervious surface | 100% LMC 18A.60.040(A) | |
| Minimum parking | The requirements for any use not listed herein shall be those of the listed use most similar to the unlisted use. When similarity is not apparent, the Director shall determine the minimum and maximum for the unlisted use. LMC 18A.80.030(A) | 2 spaces per unit LMC 18C.600.610(A)
for Detached single-family, including manufactured homes (1 unit) Sufficient existing parking must be retained to satisfy the number required for existing residential units and nonresidential uses that remain after the new residential units are added; LMC 18A.40.110(B)(15)(b); 18A.40.110(B)(15)(f)
for Use of existing buildings for residential purposes (1, 2, 3, 4+ units)3 for Two-family residential, attached or detached dwelling units. Duplex. (2 units); Stacked flats (2, 3 units); Cottage housing (2, 3 units); Courtyard apartments (2, 3 units); Rowhouses (2, 3 units); Three-family residential, attached or detached dwelling units. Triplex. (3 units); Townhouse (3 units)
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units); Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units); Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units); Townhouse (4+ units); Stacked flats (4+ units); Cottage housing (4+ units); Courtyard apartments (4+ units); Mixed use (4+ units); Rowhouses (4+ units) for Multifamily, seven or more residential units (4+ units) 1.5 spaces per unit LMC 18A.80.030(F); 18A.40.110(C)(7)
for Mobile home parks (4+ units) main dwelling units on the lot ÷ 3 spaces LMC 18C.600.610(A)
for Specialized senior housing (4+ units) for Boarding house (group living) for Co-living housing (group living) The minimum number of off-street parking spaces required for each facility will be determined by the Director through the approval process per Chapter 18A.80, 18B.600, or 18C.600 LMC and taking into consideration factors such as the potential number of residents, site constraints, and impact on the surrounding neighborhood. LMC 18A.40.120(C)(5)(b)(i)(b)(iii)
0.5 spaces per bed LMC 18A.80.030(F)
for Nursing Home (group living) |
| Maximum unit size | Not set LMC 18A.60.040(A) | 300 sq ft LMC 18A.40.110(B)(14)(a)(i)
for Co-living housing (group living) |
| Maximum lot size | Not set LMC 18A.60.040(A) | 871,200 sq ft LMC 18A.40.110(C)(5)
for Mobile home parks (4+ units) |
| Minimum open space | Not set LMC 18A.60.040(A) | 10% LMC 18A.40.110(C)(8)
for Mobile home parks (4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units LMC 18A.40.110(B)(1)(a); 18A.40.110(B)(1)(d) | 1 unit LMC 18A.40.110(B)(1)(b)
for Detached single-family, including manufactured homes (1 unit)2; Live/work and work/live units (1, 2, 3, 4+ units)2; Use of existing buildings for residential purposes (1, 2, 3, 4+ units)5; Two-family residential, attached or detached dwelling units. Duplex. (2 units)2; Stacked flats (2, 3, 4+ units)2; Cottage housing (2, 3, 4+ units)2; Courtyard apartments (2, 3, 4+ units)2; Rowhouses (2, 3, 4+ units)2; Three-family residential, attached or detached dwelling units. Triplex. (3 units)2; Townhouse (3, 4+ units)2; Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units)2; Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units)2; Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units)2; Multifamily, seven or more residential units (4+ units)2; Mixed use (4+ units)2; Mobile home parks (4+ units)2; Specialized senior housing (4+ units)2; Foster care facility (group living)2; Type 1 Group Home, adult family home (group living)2; Type 2 Group Home (group living)2 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | The minimum distance setbacks for the Station District shall be determined by frontage type in Chapter 18C.400 LMC, except where increased setbacks due to building/fire code requirements apply. LMC 18C.200.230(D); 18C.400.410(A) | |
| Side setback | 0 ft LMC 18A.60.040(A) | |
| Rear setback | 0 ft LMC 18A.60.040(A) | |
| Maximum height | 90 ft LMC 18A.60.040(A); 18C.200.230(E) | |
| Minimum parking | ||
| Maximum unit size | ||
| Attached to the main house | Not required LMC 18A.40.110(B)(1)(c) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision LMC 17.22.070(A) | A | up to 9 LMC 17.02.035 | — | Minimum lot size No limit LMC 18C.200.230(B) Minimum lot width 50 ft LMC 18A.60.090(A)(4) |
| Subdivision LMC 17.14.010 | H | 10 or more LMC 17.02.035; 17.10.020(A) | — | Minimum lot size No limit LMC 18C.200.230(B) Minimum lot width 50 ft LMC 18A.60.090(A)(4) |
| Plats with private streets LMC 17.26.010; 17.26.020; 17.22.070(A) | A | up to 9 LMC 17.26.020; 17.02.035 | — | Minimum lot size No limit LMC 18C.200.230(B) Minimum lot width 50 ft LMC 18A.60.090(A)(4) |
| Plats with private streets LMC 17.26.010; 17.26.020; 17.14.010 | H | 10 or more LMC 17.26.020; 17.02.035 | — | Minimum lot size No limit LMC 18C.200.230(B) Minimum lot width 50 ft LMC 18A.60.090(A)(4) |
| Residential condominium binding site plan LMC 17.34.010; 17.34.030; 17.34.030(D) | A35 | — | — | Minimum lot size Not set LMC 17.34.030 |
| Unit lot subdivision LMC 17.24.040(B); 17.22.070(A); 17.24.020(A)-(B) | A36 | up to 9 LMC 17.24.040(B) | Maximum parent area 87,120 sq ft LMC 17.24.020(D); 17.24.020(G); 17.24.030(D) Minimum units 2 units LMC 17.24.020(D) |
Minimum lot size No limit LMC 17.24.030(B) |
| Unit lot subdivision LMC 17.24.040(A); 17.14.010; 17.24.020(A)-(B) | H37 | 10 or more LMC 17.24.040(A); 17.02.035 | Maximum parent area 87,120 sq ft LMC 17.24.020(D); 17.24.020(G); 17.24.030(D) Minimum units 2 units LMC 17.24.020(D) |
Minimum lot size No limit LMC 17.24.030(B) |
| Binding site plan LMC 17.30.045(A) | A | 2 or more LMC 17.30.020(A) | — | Minimum lot size No limit LMC 18C.200.230(B) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The lot is designated with critical areas or their buffers
- The lot is designated with critical areas or their buffers
- All of these are true:
- The building is an existing building (certificate of occupancy at least 3 years before the application)
- The existing building has ground floor commercial or retail along a major pedestrian corridor
- All of these are true:
- The building is an existing building (certificate of occupancy at least 3 years before the application)
- The existing building has ground floor commercial or retail along a major pedestrian corridor
- The lot is designated with critical areas or their buffers
- All of these are true:
- The building is an existing building (certificate of occupancy at least 3 years before the application)
- The lot is designated with critical areas or their buffers
- The existing building has ground floor commercial or retail along a major pedestrian corridor
- The dormitory, fraternity or sorority is accessory to a public or private educational institution or church
- Any of these is true:
- None of these is true:
- Another property within an 880 foot radius has emergency housing or an emergency shelter
- The facility is sponsored by the same governmental, religious, or not-for-profit agency as the nearby emergency housing or shelter
- None of these is true:
- Lot is a flag lot
- None of these is true:
- Lot is a flag lot
- None of these is true:
- The project uses an inclusionary or religious-organization density bonus of Chapter 18A.90 LMC
- The project uses an inclusionary or religious-organization density bonus of Chapter 18A.90 LMC
- All of these are true:
- The Type 1 group home is an adult family home
- The adult family home has department approval under RCW 70.128.066 to serve up to eight adults
- All of these are true:
- The Type 1 group home is an adult family home
- The adult family home has department approval under RCW 70.128.066 to serve up to eight adults
- None of these is true:
- The Type 1 group home is an adult family home
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- All of these are true:
- Lot area is at most 6,000 sf
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- All of these are true:
- Lot area is more than 6,000 sf
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- All of these are true:
- Lot area is at most 6,000 sf
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- Lot area is more than 6,000 sf
- Bedrooms in one unit is 0
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- Lot area is more than 6,000 sf
- Bedrooms in one unit is 1
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- Lot area is more than 6,000 sf
- Bedrooms in one unit is at least 2
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- All of these are true:
- The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
- The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
- Bedrooms in one unit is 0
- Bedrooms in one unit is at least 1
- The lot is within 1/4 mile of a commuter rail or bus rapid transit stop
- None of these is true:
- The lot is within 1/4 mile of a commuter rail or bus rapid transit stop
- The lot is within 1/2 mile walking distance of a major transit stop as defined in RCW 36.70A.535
- None of these is true:
- The lot is within 1/2 mile walking distance of a major transit stop as defined in RCW 36.70A.535
- The cottage units are owned as condominium units with property owned in common
- None of these is true:
- The cottage units are owned as condominium units with property owned in common
- The lot is within 1/2 mile of the Sounder Station or a bus rapid transit stop
- None of these is true:
- The lot is within 1/2 mile of the Sounder Station or a bus rapid transit stop
- The ADU is attached ADU contained within or attached to an existing single-family structure
- None of these is true:
- The ADU is attached ADU contained within or attached to an existing single-family structure
- All of these are true:
- The project is a residential condominium that proposes to subdivide land into separate lots
- A building permit has been issued for the entire project
- None of these is true:
- The unit lot subdivision creates 10 or more lots
- The unit lot subdivision creates 10 or more lots