Sign in

TOC · Transit-Oriented Commercial

Lakewood, WA · LMC 18C.200 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached single-family, including manufactured homes
Home✓ ADU✓1 ✓2
————
Live/work and work/live units
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
—
Use of existing buildings for residential purposes
Home✓3 ADU✓4 ✓5
Home✓3 ADU✓4 ✓5
Home✓3 ADU✓4 ✓5
Home✓3 ADU✓4 ✓5
—
Two-family residential, attached or detached dwelling units. Duplex.—
Home✓ ADU✓1 ✓2
———
Stacked flats—
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
—
Cottage housing—
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
—
Courtyard apartments—
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
—
Rowhouses—
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
—
Three-family residential, attached or detached dwelling units. Triplex.——
Home✓ ADU✓1 ✓2
——
Townhouse——
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
—
Multifamily: Four-family residential, attached or detached dwelling units. Fourplex.———
Home✓ ADU✓1 ✓2
—
Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex.———
Home✓ ADU✓1 ✓2
—
Multifamily: Six-family residential, attached or detached dwelling units. Sixplex.———
Home✓ ADU✓1 ✓2
—
Multifamily, seven or more residential units———
Home✓ ADU✓1 ✓2
—
Mixed use———
Home✓ ADU✓1 ✓2
—
Mobile home parks———
HomeH ADU✓1 ✓2
—
Specialized senior housing———
HomeH ADU✓1 ✓2
—
Boarding house————
HomeH ADU—
Co-living housing————
Home✓ ADU—
Co-housing (dormitories, fraternities and sororities)————
Home✓6 ADU—
Foster care facility————
Home✓ ADU✓1 ✓2
Assisted Living Facility————
Home✓ ADU—
Confidential Shelter————
Home✓ ADU—
Continuing Care Retirement Community————
Home✓ ADU—
Emergency Housing————
HomeA7 ADU—
Emergency Shelter————
HomeA7 ADU—
Enhanced Services Facility————
HomeH ADU—
Hospice Care Center————
Home✓ ADU—
Nursing Home————
Home✓ ADU—
Permanent Supportive Housing————
HomeA ADU—
Rapid Re-Housing————
Home✓ ADU—
Transitional Housing————
HomeA ADU—
Type 1 Group Home, adult family home————
Home✓ ADU✓1 ✓2
Type 2 Group Home————
Home✓ ADU✓1 ✓2
Type 3 Group Home————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set LMC 18A.10.180
4 units LMC 18A.10.180
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units)
5 units LMC 18A.10.180
for Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units)
6 units LMC 18A.10.180
for Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units)
Minimum unitsNot set LMC 18A.10.180
4 units LMC 18A.10.180
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units)
5 units LMC 18A.10.180
for Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units)
6 units LMC 18A.10.180
for Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units)
7 units LMC 18A.10.180
for Multifamily, seven or more residential units (4+ units)
3 units LMC 18A.10.180
for Townhouse (4+ units)
2 units LMC 18A.10.180
for Mobile home parks (4+ units); Specialized senior housing (4+ units)
Minimum lot sizeNo limit LMC 18C.200.230(B)
Minimum lot width50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft8 LMC 18A.60.090(B)(9)(b)
  • 50 ft9 LMC 18A.60.090(A)(5)
Maximum densityNot set LMC 18A.60.040(A)
80 units per acre, a fraction of 0.5 or more rounds up LMC 18A.60.040(A); 18A.60.110(G); 18C.200.230(A)
for Detached single-family, including manufactured homes (1 unit); Live/work and work/live units (1, 2, 3 units); Two-family residential, attached or detached dwelling units. Duplex. (2 units); Stacked flats (2, 3 units); Cottage housing (2, 3 units); Courtyard apartments (2, 3 units); Rowhouses (2, 3 units); Three-family residential, attached or detached dwelling units. Triplex. (3 units); Townhouse (3 units)
80 × 1.5 units per acre, a fraction of 0.5 or more rounds up LMC 18A.60.040(A); 18A.40.110(B)(15)(a); 18A.60.110(G)
for Use of existing buildings for residential purposes (1, 2, 3, 4+ units)3
  • 80 units per acre, a fraction of 0.5 or more rounds up10 LMC 18A.60.040(A); 18A.60.110(G); 18C.200.230(A)
  • 80 × 1.25 units per acre, a fraction of 0.5 or more rounds up11 LMC 18A.60.040(A); 18A.60.110(G); 18C.200.230(A); 18A.90.050(A)
for Live/work and work/live units (4+ units); Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units); Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units); Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units); Multifamily, seven or more residential units (4+ units); Townhouse (4+ units); Stacked flats (4+ units); Cottage housing (4+ units); Courtyard apartments (4+ units); Mixed use (4+ units); Mobile home parks (4+ units); Specialized senior housing (4+ units); Rowhouses (4+ units)
Minimum development sizeNot set LMC 18A.60.040(A)
130,680 sq ft LMC 18A.40.110(C)(5); 18A.40.110(C)(2)(b)
for Mobile home parks (4+ units)
Maximum residentsNot set LMC 18A.10.180
  • 8 persons12 LMC 18A.10.180
  • 6 persons13 LMC 18A.10.180
  • Not set14 LMC 18A.10.180
for Type 1 Group Home, adult family home (group living)
Maximum sleeping unitsNot set LMC 18A.10.180
4 × ((80 × lot area) ÷ 43,560, rounded) sleeping units LMC 18A.60.040(A); 18A.40.110(B)(14)(d)
for Co-living housing (group living)

3. Building standards

StandardValueExceptions
Front setbackThe minimum distance setbacks for the Station District shall be determined by frontage type in Chapter 18C.400 LMC, except where increased setbacks due to building/fire code requirements apply. LMC 18C.200.230(D); 18C.400.410(A)
Maximum front setbackThe maximum setback shall be up to 10 feet where the Department of Planning a Public Works (PPW) Director has determined property may be needed to accommodate the City’s planned right-of-way at full build-out. Otherwise, the maximum setback is zero (0) feet. LMC 18C.400.410(A)(1)
Side setback0 ft LMC 18A.60.040(A)
Street side setbackThe minimum distance setbacks for the Station District shall be determined by frontage type in Chapter 18C.400 LMC, except where increased setbacks due to building/fire code requirements apply. LMC 18C.200.230(D); 18C.400.410(A)
Rear setback0 ft LMC 18A.60.040(A)
Maximum height90 ft LMC 18A.60.040(A); 18C.200.230(E)
Maximum storiesNot set LMC 18A.60.040(A)
3 stories LMC 18A.10.180
for Stacked flats (2, 3, 4+ units)
Maximum lot coverageNo limit LMC 18C.200.230(C)
Maximum impervious surface100% LMC 18A.60.040(A)
Minimum parkingThe requirements for any use not listed herein shall be those of the listed use most similar to the unlisted use. When similarity is not apparent, the Director shall determine the minimum and maximum for the unlisted use. LMC 18A.80.030(A)
2 spaces per unit LMC 18C.600.610(A)
for Detached single-family, including manufactured homes (1 unit)
Sufficient existing parking must be retained to satisfy the number required for existing residential units and nonresidential uses that remain after the new residential units are added; LMC 18A.40.110(B)(15)(b); 18A.40.110(B)(15)(f)
for Use of existing buildings for residential purposes (1, 2, 3, 4+ units)3
  • 0 spaces per unit15 LMC 18A.80.030(F); 18A.80.030(G)(5)
  • 1 space per unit16 LMC 18A.80.030(F)
  • 2 spaces per unit17 LMC 18A.80.030(F)
for Two-family residential, attached or detached dwelling units. Duplex. (2 units); Stacked flats (2, 3 units); Cottage housing (2, 3 units); Courtyard apartments (2, 3 units); Rowhouses (2, 3 units); Three-family residential, attached or detached dwelling units. Triplex. (3 units); Townhouse (3 units)
  • 0 spaces per unit15 LMC 18A.80.030(F); 18A.80.030(G)(5)
  • 1 space per unit18 LMC 18A.80.030(F)
  • 1 space per unit19 LMC 18A.80.030(F)
  • 1.25 spaces per unit20 LMC 18A.80.030(F)
  • 1.5 spaces per unit21 LMC 18A.80.030(F)
  • the smallest of 2, the largest of 0.75, bedrooms in one unit spaces per unit22 LMC 18A.80.030(G)(6)(a)
for Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units); Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units); Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units); Townhouse (4+ units); Stacked flats (4+ units); Cottage housing (4+ units); Courtyard apartments (4+ units); Mixed use (4+ units); Rowhouses (4+ units)
  • 1 space per unit23 LMC 18C.600.610(A)
  • 1.25 spaces per unit24 LMC 18C.600.610(A)
for Multifamily, seven or more residential units (4+ units)
1.5 spaces per unit LMC 18A.80.030(F); 18A.40.110(C)(7)
for Mobile home parks (4+ units)
main dwelling units on the lot ÷ 3 spaces LMC 18C.600.610(A)
for Specialized senior housing (4+ units)
  • 0.75 spaces per sleeping unit25 LMC 18A.40.110(B)(2)(a)
  • 1 space per resident26 LMC 18A.40.110(B)(2)(a)
for Boarding house (group living)
  • 0 spaces per sleeping unit27 LMC 18A.40.110(B)(14)(g); 18A.40.110(B)(14)(g)(i)
  • 0.25 spaces per sleeping unit28 LMC 18A.40.110(B)(14)(g)(ii)
for Co-living housing (group living)
The minimum number of off-street parking spaces required for each facility will be determined by the Director through the approval process per Chapter 18A.80, 18B.600, or 18C.600 LMC and taking into consideration factors such as the potential number of residents, site constraints, and impact on the surrounding neighborhood. LMC 18A.40.120(C)(5)(b)(i)(b)(iii)
for Emergency Housing (group living)7; Emergency Shelter (group living)7; Permanent Supportive Housing (group living); Transitional Housing (group living)
0.5 spaces per bed LMC 18A.80.030(F)
for Nursing Home (group living)
Maximum unit sizeNot set LMC 18A.60.040(A)
300 sq ft LMC 18A.40.110(B)(14)(a)(i)
for Co-living housing (group living)
Maximum lot sizeNot set LMC 18A.60.040(A)
871,200 sq ft LMC 18A.40.110(C)(5)
for Mobile home parks (4+ units)
Minimum open spaceNot set LMC 18A.60.040(A)
  • 20%29 LMC 18A.10.180
  • Not set30 LMC 18A.10.180
for Cottage housing (2, 3, 4+ units)
10% LMC 18A.40.110(C)(8)
for Mobile home parks (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units LMC 18A.40.110(B)(1)(a); 18A.40.110(B)(1)(d)
1 unit LMC 18A.40.110(B)(1)(b)
for Detached single-family, including manufactured homes (1 unit)2; Live/work and work/live units (1, 2, 3, 4+ units)2; Use of existing buildings for residential purposes (1, 2, 3, 4+ units)5; Two-family residential, attached or detached dwelling units. Duplex. (2 units)2; Stacked flats (2, 3, 4+ units)2; Cottage housing (2, 3, 4+ units)2; Courtyard apartments (2, 3, 4+ units)2; Rowhouses (2, 3, 4+ units)2; Three-family residential, attached or detached dwelling units. Triplex. (3 units)2; Townhouse (3, 4+ units)2; Multifamily: Four-family residential, attached or detached dwelling units. Fourplex. (4+ units)2; Multifamily: Five-family residential, attached or detached dwelling units. Fiveplex. (4+ units)2; Multifamily: Six-family residential, attached or detached dwelling units. Sixplex. (4+ units)2; Multifamily, seven or more residential units (4+ units)2; Mixed use (4+ units)2; Mobile home parks (4+ units)2; Specialized senior housing (4+ units)2; Foster care facility (group living)2; Type 1 Group Home, adult family home (group living)2; Type 2 Group Home (group living)2

Building

StandardValueExceptions
Front setbackThe minimum distance setbacks for the Station District shall be determined by frontage type in Chapter 18C.400 LMC, except where increased setbacks due to building/fire code requirements apply. LMC 18C.200.230(D); 18C.400.410(A)
Side setback0 ft LMC 18A.60.040(A)
Rear setback0 ft LMC 18A.60.040(A)
Maximum height90 ft LMC 18A.60.040(A); 18C.200.230(E)
Minimum parking
  • 0 spaces per unit31 LMC 18C.600.610(A)
  • 1 space per unit32 LMC 18C.600.610(A)
Maximum unit size
  • The maximum size of an attached ADU contained within or attached to an existing single-family structure shall be limited by the existing structure’s applicable zoning requirements.33 LMC 18A.40.110(B)(1)(e)
  • 1,200 sq ft34 LMC 18A.40.110(B)(1)(e)
Attached to the main houseNot required LMC 18A.40.110(B)(1)(c)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision LMC 17.22.070(A) A up to 9 LMC 17.02.035 —
Minimum lot size
No limit LMC 18C.200.230(B)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft8 LMC 18A.60.090(B)(9)(b)
  • 50 ft9 LMC 18A.60.090(A)(5)
Subdivision LMC 17.14.010 H 10 or more LMC 17.02.035; 17.10.020(A) —
Minimum lot size
No limit LMC 18C.200.230(B)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft8 LMC 18A.60.090(B)(9)(b)
  • 50 ft9 LMC 18A.60.090(A)(5)
Plats with private streets LMC 17.26.010; 17.26.020; 17.22.070(A) A up to 9 LMC 17.26.020; 17.02.035 —
Minimum lot size
No limit LMC 18C.200.230(B)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft8 LMC 18A.60.090(B)(9)(b)
  • 50 ft9 LMC 18A.60.090(A)(5)
Plats with private streets LMC 17.26.010; 17.26.020; 17.14.010 H 10 or more LMC 17.26.020; 17.02.035 —
Minimum lot size
No limit LMC 18C.200.230(B)
Minimum lot width
50 ft LMC 18A.60.090(A)(4)
Minimum frontage
  • 24 ft8 LMC 18A.60.090(B)(9)(b)
  • 50 ft9 LMC 18A.60.090(A)(5)
Residential condominium binding site plan LMC 17.34.010; 17.34.030; 17.34.030(D) A35 — —
Minimum lot size
Not set LMC 17.34.030
Unit lot subdivision LMC 17.24.040(B); 17.22.070(A); 17.24.020(A)-(B) A36 up to 9 LMC 17.24.040(B)
Maximum parent area
87,120 sq ft LMC 17.24.020(D); 17.24.020(G); 17.24.030(D)
Minimum units
2 units LMC 17.24.020(D)
Minimum lot size
No limit LMC 17.24.030(B)
Unit lot subdivision LMC 17.24.040(A); 17.14.010; 17.24.020(A)-(B) H37 10 or more LMC 17.24.040(A); 17.02.035
Maximum parent area
87,120 sq ft LMC 17.24.020(D); 17.24.020(G); 17.24.030(D)
Minimum units
2 units LMC 17.24.020(D)
Minimum lot size
No limit LMC 17.24.030(B)
Binding site plan LMC 17.30.045(A) A 2 or more LMC 17.30.020(A) —
Minimum lot size
No limit LMC 18C.200.230(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The lot is designated with critical areas or their buffers
  2. The lot is designated with critical areas or their buffers
  3. All of these are true:
    • The building is an existing building (certificate of occupancy at least 3 years before the application)
    None of these is true:
    • The existing building has ground floor commercial or retail along a major pedestrian corridor
  4. All of these are true:
    • The building is an existing building (certificate of occupancy at least 3 years before the application)
    None of these is true:
    • The existing building has ground floor commercial or retail along a major pedestrian corridor
    • The lot is designated with critical areas or their buffers
  5. All of these are true:
    • The building is an existing building (certificate of occupancy at least 3 years before the application)
    • The lot is designated with critical areas or their buffers
    None of these is true:
    • The existing building has ground floor commercial or retail along a major pedestrian corridor
  6. The dormitory, fraternity or sorority is accessory to a public or private educational institution or church
  7. Any of these is true:
    • None of these is true:
      • Another property within an 880 foot radius has emergency housing or an emergency shelter
    • The facility is sponsored by the same governmental, religious, or not-for-profit agency as the nearby emergency housing or shelter
  8. Lot is a flag lot
  9. None of these is true:
    • Lot is a flag lot
  10. None of these is true:
    • The project uses an inclusionary or religious-organization density bonus of Chapter 18A.90 LMC
  11. The project uses an inclusionary or religious-organization density bonus of Chapter 18A.90 LMC
  12. All of these are true:
    • The Type 1 group home is an adult family home
    • The adult family home has department approval under RCW 70.128.066 to serve up to eight adults
  13. All of these are true:
    • The Type 1 group home is an adult family home
    None of these is true:
    • The adult family home has department approval under RCW 70.128.066 to serve up to eight adults
  14. None of these is true:
    • The Type 1 group home is an adult family home
  15. The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
  16. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
  17. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
  18. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  19. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one unit is 0
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  20. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one unit is 1
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  21. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one unit is at least 2
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
  22. All of these are true:
    • The housing unit is within 1/2 mile of a transit stop that receives transit service at least two times per hour for twelve or more hours per day
    None of these is true:
    • The housing unit is within 1/2 mile of a major transit stop (commuter rail or bus rapid transit)
  23. Bedrooms in one unit is 0
  24. Bedrooms in one unit is at least 1
  25. The lot is within 1/4 mile of a commuter rail or bus rapid transit stop
  26. None of these is true:
    • The lot is within 1/4 mile of a commuter rail or bus rapid transit stop
  27. The lot is within 1/2 mile walking distance of a major transit stop as defined in RCW 36.70A.535
  28. None of these is true:
    • The lot is within 1/2 mile walking distance of a major transit stop as defined in RCW 36.70A.535
  29. The cottage units are owned as condominium units with property owned in common
  30. None of these is true:
    • The cottage units are owned as condominium units with property owned in common
  31. The lot is within 1/2 mile of the Sounder Station or a bus rapid transit stop
  32. None of these is true:
    • The lot is within 1/2 mile of the Sounder Station or a bus rapid transit stop
  33. The ADU is attached ADU contained within or attached to an existing single-family structure
  34. None of these is true:
    • The ADU is attached ADU contained within or attached to an existing single-family structure
  35. All of these are true:
    • The project is a residential condominium that proposes to subdivide land into separate lots
    • A building permit has been issued for the entire project
  36. None of these is true:
    • The unit lot subdivision creates 10 or more lots
  37. The unit lot subdivision creates 10 or more lots