Sign in

RL · Residential Low Density

Lewis County, WA · LCC 17.17 · Official code

By right: 1 unit, 2 units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family residential
Home✓ ADU✓
————
Duplex—
Home✓ ADU—
———
Cottage housing——
HomeA1 ADU—
HomeA1 ADU—
—
Manufactured home park——
HomeA1 ADU—
HomeA1 ADU—
—
Assisted living facility, adult family home————
Home✓ ADU✓
Co-living, except assisted living facility, adult family home————
Home✓ ADU—
Detached bedroom————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum units3 units LCC 17.10.030
Not set LCC 17.17.100
for Manufactured home park (4+ units)1
Minimum lot size5,000 sq ft LCC 17.17.100(3)
Minimum lot width35 ft LCC 17.17.100(3)
Minimum density
  • 4 units per acre2 LCC 17.17.100(3)
  • If the nearest centralized wastewater treatment hookup is located more than 200 feet from the parcel, the minimum density in Table 1 may be reduced in accordance with Chapter 8.40 LCC, On-Site Sewage Systems.3 LCC 17.17.100(2)(a)
Not set LCC 17.17.100(3)
for Assisted living facility, adult family home (group living); Assisted living facility, adult family home (group living)4; Co-living, except assisted living facility, adult family home (group living); Detached bedroom (group living)
Maximum density
  • 12 units per acre5 LCC 17.17.100(3)
  • 12 × 1.25 units per acre6 LCC 17.17.100(3); 17.17.210(1)
Not set LCC 17.17.100(3)
for Assisted living facility, adult family home (group living); Assisted living facility, adult family home (group living)4; Co-living, except assisted living facility, adult family home (group living); Detached bedroom (group living)
Maximum residentsNot set LCC 17.42.020
6 persons LCC 17.42.020
for Assisted living facility, adult family home (group living)
Maximum sleeping unitsNot set LCC 17.42.020
  • 4 × ((12 × lot area) ÷ 43,560, rounded down) sleeping units5 LCC 17.17.100(3); 17.10.190
  • 4 × (((12 × 1.25) × lot area) ÷ 43,560, rounded down) sleeping units6 LCC 17.17.100(3); 17.17.210(1); 17.10.190
for Co-living, except assisted living facility, adult family home (group living)
2 sleeping units LCC 17.142.107(1)
for Detached bedroom (group living)

3. Building standards

StandardValueExceptions
Front setback20 ft LCC 17.17.120(1)
Side setback5 ft LCC 17.17.120(1)
Rear setback10 ft LCC 17.17.120(1)
Building separationNot set LCC 17.17.120
10 ft LCC 15.30.060(1)(b)(i)
for Manufactured home park (3, 4+ units)1
Maximum height35 ft LCC 17.17.120(1)
Minimum parking1 space per unit LCC 17.17.120(1)
2 spaces per unit LCC 17.17.120(1); 17.17.220(3)(a)
for Single-family residential (1 unit)
Maximum unit sizeNot set LCC 17.17.120
1,000 sq ft LCC 17.10.030
for Cottage housing (3, 4+ units)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units LCC 17.17.130(1)

Building

StandardValueExceptions
Front setback20 ft LCC 17.17.120(1)
Side setback
  • 0 ft7 LCC 17.17.130(3)
  • 5 ft8 LCC 17.17.120(1)
Rear setback
  • 0 ft9 LCC 17.17.130(3)
  • 10 ft10 LCC 17.17.120(1)
Maximum height35 ft LCC 17.17.120(1)
Minimum parking1 space per unit LCC 17.17.220(3)(a)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision LCC 16.05.050; 17.05.040(1)(c) H 5 or more LCC 16.04.310; 16.05.030(1)
  • 12 units per acre5 LCC 17.17.100(3)
  • 12 × 1.25 units per acre6 LCC 17.17.100(3); 17.17.210(1)
Minimum density
  • 4 units per acre2 LCC 17.17.100(3)
  • If the nearest centralized wastewater treatment hookup is located more than 200 feet from the parcel, the minimum density in Table 1 may be reduced in accordance with Chapter 8.40 LCC, On-Site Sewage Systems.3 LCC 17.17.100(2)(a)
Minimum lot size
5,000 sq ft LCC 17.17.100(3); 16.05.300(3)(d)
Minimum lot width
35 ft LCC 17.17.100(3); 16.05.300(4)
Minimum frontage
Not set LCC 16.05.300(5); 17.17.100
Short subdivision LCC 16.10.250; 17.05.040(1)(a) A up to 4 LCC 16.04.280; 16.10.200(1)
  • 12 units per acre5 LCC 17.17.100(3)
  • 12 × 1.25 units per acre6 LCC 17.17.100(3); 17.17.210(1)
Minimum density
  • 4 units per acre2 LCC 17.17.100(3)
  • If the nearest centralized wastewater treatment hookup is located more than 200 feet from the parcel, the minimum density in Table 1 may be reduced in accordance with Chapter 8.40 LCC, On-Site Sewage Systems.3 LCC 17.17.100(2)(a)
Minimum lot size
5,000 sq ft LCC 17.17.100(3); 16.05.300(3)(d)
Minimum lot width
35 ft LCC 17.17.100(3); 16.05.300(4)
Minimum frontage
30 ft LCC 16.10.450
Short subdivision LCC 16.10.250; 17.05.040(1)(a) A11 up to 2 LCC 17.17.100(2)(b)
  • 12 units per acre5 LCC 17.17.100(3)
  • 12 × 1.25 units per acre6 LCC 17.17.100(3); 17.17.210(1)
Minimum density
No limit LCC 17.17.100(2)(b)
Minimum lot size
5,000 sq ft LCC 17.17.100(3); 16.05.300(3)(d)
Minimum lot width
35 ft LCC 17.17.100(3); 16.05.300(4)
Minimum frontage
30 ft LCC 16.10.450
Large lot subdivision LCC 16.12.250; 17.05.040(1)(a) A 2 or more LCC 16.04.183; 16.12.020
  • 12 units per acre5 LCC 17.17.100(3)
  • 12 × 1.25 units per acre6 LCC 17.17.100(3); 17.17.210(1)
Minimum density
  • 4 units per acre2 LCC 17.17.100(3)
  • If the nearest centralized wastewater treatment hookup is located more than 200 feet from the parcel, the minimum density in Table 1 may be reduced in accordance with Chapter 8.40 LCC, On-Site Sewage Systems.3 LCC 17.17.100(2)(a)
Minimum lot size
217,800 sq ft LCC 16.04.183; 16.12.020
Minimum frontage
30 ft LCC 16.12.450
Cluster development LCC 16.05.400(2); 16.18.010(1)(c)(i) H —
  • 12 units per acre12 LCC 17.17.100(3); 16.18.010(1)(c)(ii)
  • 12 × 1.25 units per acre13 LCC 17.17.100(3); 16.18.030(1)(a)
  • 12 × 1.5 units per acre14 LCC 17.17.100(3); 16.18.030(1)(b)
Minimum lot size
The minimum lot size for clustered lots shall be determined by the health and septic standards of the county LCC 16.18.010(1)(b)
Master planned development LCC 17.17.250(3); 17.05.040(1)(c) H15 —
  • 12 units per acre5 LCC 17.17.100(3)
  • 12 × 1.25 units per acre6 LCC 17.17.100(3); 17.17.210(1)
Minimum parent area
435,600 sq ft LCC 17.17.250(2)
Minimum density
  • 4 units per acre2 LCC 17.17.100(3)
  • If the nearest centralized wastewater treatment hookup is located more than 200 feet from the parcel, the minimum density in Table 1 may be reduced in accordance with Chapter 8.40 LCC, On-Site Sewage Systems.3 LCC 17.17.100(2)(a)
Minimum lot size
5,000 sq ft LCC 17.17.100(3); 16.05.300(3)(d)
Minimum lot width
35 ft LCC 17.17.100(3); 16.05.300(4)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. A centralized wastewater treatment facility with adequate capacity serves the parcel
  2. None of these is true:
    • The nearest centralized wastewater treatment (sewer) hookup is more than 200 feet from the parcel
  3. The nearest centralized wastewater treatment (sewer) hookup is more than 200 feet from the parcel
  4. Residents is at least 7
  5. Not all of these are true:
    • At least 30 percent of the dwelling units are long-term units at or below 80 percent of Lewis County area median income
    • The project takes the residential density bonus (25 percent more dwelling units) rather than the commercial floor area bonus (30 percent more commercial square footage)
  6. All of these are true:
    • At least 30 percent of the dwelling units are long-term units at or below 80 percent of Lewis County area median income
    • The project takes the residential density bonus (25 percent more dwelling units) rather than the commercial floor area bonus (30 percent more commercial square footage)
  7. All of these are true:
    • The ADU is detached
    • A side lot line abuts a public alley on which the county does not routinely plow snow
  8. Not all of these are true:
    • The ADU is detached
    • A side lot line abuts a public alley on which the county does not routinely plow snow
  9. All of these are true:
    • The ADU is detached
    • The rear lot line abuts a public alley on which the county does not routinely plow snow
  10. Not all of these are true:
    • The ADU is detached
    • The rear lot line abuts a public alley on which the county does not routinely plow snow
  11. The RL or RM parcel existed before December 31, 2025
  12. Share of the original parcel the clustered development places in a natural resource or open space easement on the larger remainder parcel is under_50
  13. Share of the original parcel the clustered development places in a natural resource or open space easement on the larger remainder parcel is at_least_50
  14. Share of the original parcel the clustered development places in a natural resource or open space easement on the larger remainder parcel is at_least_75
  15. Lot area is at least 435,600 sf