Sign in

HBD · Historic business district (HBD)

Lynden, WA · LMC 19.23 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Residential uses on upper stories
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Residential Conversion of Commercial Space
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
—
Emergency housing, indoor; emergency shelter————
HomeA3 H4 ADU—
Permanent supportive housing————
HomeH ADU—
Residential reentry facilities————
HomeA3 H4 ADU—
Transitional housing————
HomeA5 H6 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum residentsfloor area of all units ÷ 350, rounded down persons LMC 19.49.110(C)(2)(a)
Not set LMC 19.49.060(C)(2)
for Emergency housing, indoor; emergency shelter (group living)3
floor area of all units ÷ 35, rounded down persons LMC 19.49.060(C)(2)(b)
for Emergency housing, indoor; emergency shelter (group living)4
the smallest of 6, floor area of all units ÷ 350, rounded down persons LMC 19.49.100(C)(2)(b); 19.49.100(C)(2)(a)
for Transitional housing (group living)5
the smallest of 30, floor area of all units ÷ 350, rounded down persons LMC 19.49.100(C)(2)(c); 19.49.100(C)(2)(a)
for Transitional housing (group living)6
Maximum bedsNot set LMC 19.49.030
6 beds LMC 19.49.060(C)(2)(a)
for Emergency housing, indoor; emergency shelter (group living)3; Residential reentry facilities (group living)3
80 beds LMC 19.49.060(C)(2)(b)
for Emergency housing, indoor; emergency shelter (group living)4
12 beds LMC 19.49.090(C)(2)(b)
for Residential reentry facilities (group living)4

3. Building standards

StandardValueExceptions
Front setback0 ft LMC 19.23.050(A)
Side setback0 ft LMC 19.23.050(A) note (3)
Street side setback10 ft LMC 19.23.050(A) note (3)
Rear setback20 ft LMC 19.23.050(A)
Maximum height48 ft LMC 19.23.050(A)
Minimum parking1 × bedrooms in the whole project spaces LMC 19.51.040; 19.49.060(C)(5)(d)
  • 1 space per unit7 LMC 19.51.160(B)(2)
  • 2 spaces per unit8 LMC 19.51.040
  • 1 × bedrooms in one unit spaces per unit9 LMC 19.51.040
for Residential uses on upper stories (1, 2, 3, 4+ units)1
0 spaces per unit LMC 19.23.120(C)(3)
for Residential Conversion of Commercial Space (1, 2, 3, 4+ units)2

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision LMC 18.12.010 A up to 4 LMC 18.12.010; 17.01.030 —
Minimum lot size
Not set LMC 19.23.050(A)
Minimum frontage
50 ft LMC 18.14.020(B)
Subdivision LMC 18.16.020; 17.03.040(A)(1) H 5 or more LMC 17.01.030 —
Minimum lot size
Not set LMC 19.23.050(A)
Minimum frontage
50 ft LMC 18.14.020(B)
Binding site plan LMC 18.24.050(B); 17.03.040(A)(1) H
Minimum lots
Not set LMC 18.24.010
—
Minimum lot size
Not set LMC 19.23.050(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The residential units are on upper stories of a building with commercial space on the ground floor
  2. The building received a certificate of occupancy at least three years prior to the permit application to add housing units
  3. Beds in the project is at most 6
  4. Beds in the project is more than 6
  5. Residents is at most 6
  6. Residents is more than 6
  7. The lot is in the downtown parking area between Judson Alley and the alley north of Grover Street, from 2nd Street to 8th Street
  8. All of these are true:
    • Bedrooms in one unit is at most 2
    None of these is true:
    • The lot is in the downtown parking area between Judson Alley and the alley north of Grover Street, from 2nd Street to 8th Street
  9. All of these are true:
    • Bedrooms in one unit is more than 2
    None of these is true:
    • The lot is in the downtown parking area between Judson Alley and the alley north of Grover Street, from 2nd Street to 8th Street