Sign in

PBZ · Planned Business

Mercer Island, WA · MICC 19.04.010 · Official code

By right: 1 unit · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family detached
Home✓ ADU—
————
Single-family semi-detached
Home✓ ADU—
————
Townhouses
Home✓ ADU—
————
Patio homes
Home✓ ADU—
————
Development of new dwelling units in an existing building
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Special needs group housing————
Home✓ ADU—
Social service transitional housing————
Home✓2 H3 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum residentsThe facility shall comply with all applicable construction codes set forth in MICC title 17, including maximum occupancy restrictions. MICC 19.06.080(A)(1)(b)
Maximum sleeping unitsNot set MICC 19.04.010
The city shall determine the number of dwelling units or occupancy rooms or suites permitted in the proposed facility MICC 19.06.080(B)(3)(i); 19.06.080(B)(3)(i)(i)-(iii)
for Social service transitional housing (group living)3

3. Building standards

StandardValueExceptions
Front setback
  • 20 ft4 MICC 19.04.010(F)(5)(a)(i)
  • For all other residential parcels, there shall be no minimum standards for yards, except for the perimeter buffer requirements as established in subsection (D)(1) of this section.5 MICC 19.04.010(F)(5)(b)
Side setback
  • 5 ft4 MICC 19.04.010(F)(5)(a)(iii)
  • For all other residential parcels, there shall be no minimum standards for yards, except for the perimeter buffer requirements as established in subsection (D)(1) of this section.5 MICC 19.04.010(F)(5)(b)
Total side setbacks
  • 15 ft4 MICC 19.04.010(F)(5)(a)(iii)
  • For all other residential parcels, there shall be no minimum standards for yards, except for the perimeter buffer requirements as established in subsection (D)(1) of this section.5 MICC 19.04.010(F)(5)(b)
Street side setback
  • 10 ft4 MICC 19.04.010(F)(5)(a)(iii)
  • For all other residential parcels, there shall be no minimum standards for yards, except for the perimeter buffer requirements as established in subsection (D)(1) of this section.5 MICC 19.04.010(F)(5)(b)
Rear setback
  • 25 ft4 MICC 19.04.010(F)(5)(a)(ii)
  • For all other residential parcels, there shall be no minimum standards for yards, except for the perimeter buffer requirements as established in subsection (D)(1) of this section.5 MICC 19.04.010(F)(5)(b)
Maximum height30 ft MICC 19.04.010(F)(2)
Maximum lot coverage35% MICC 19.04.010(F)(4)
Maximum floor area ratio0.45 MICC 19.04.010(F)(4)
Minimum parkingNot set MICC 19.04.040(A)
0 spaces per unit MICC 19.06.140(D)
for Development of new dwelling units in an existing building (1, 2, 3, 4+ units)1
The facility has adequate off-street parking. The code official may require the applicant to submit a traffic study. MICC 19.06.080(B)(3)(h)
for Social service transitional housing (group living)3
Maximum building floor area2,800 sq ft MICC 19.04.010(F)(4)
Maximum units per building4 units MICC 19.04.010(F)(6)(b)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision or short plat MICC 19.08.020(A); 19.15.030 A up to 4 MICC 19.16.010
Minimum average lot size
7,200 sq ft MICC 19.04.010(F)(3)
Minimum lot size
Not set MICC 19.04.010
Long subdivision or long plat MICC 19.08.020(A); 19.15.030 H 5 or more MICC 19.16.010
Minimum average lot size
7,200 sq ft MICC 19.04.010(F)(3)
Minimum lot size
Not set MICC 19.04.010
Binding site plan MICC 19.04.010(H)(2)(c); 19.04.010(H)(1) H6
Maximum lots
Not set MICC 19.04.010(H)
Minimum average lot size
7,200 sq ft MICC 19.04.010(F)(3)
Minimum lot size
Not set MICC 19.04.010(H)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The building received a certificate of occupancy at least three years before the permit application to add housing units
  2. The facility houses persons with familial status and persons with handicaps within the meaning of the FHAA
  3. All of these are true:
    • The facility is at least 1,000 feet from any other social service transitional housing facility
    • Any of these is true:
      • The facility is at least 600 feet from the property line of educational or recreational facilities where children are known to congregate
      • The facility is a domestic violence shelter
    None of these is true:
    • The facility houses persons with familial status and persons with handicaps within the meaning of the FHAA
  4. Residential parcel fronts on 68th Street SE
  5. None of these is true:
    • Residential parcel fronts on 68th Street SE
  6. Any of these is true:
    • The division of lots or parcels is for a permitted light industrial or commercial use in the PBZ
    • The division of land is made by subjecting a portion of a parcel of land to RCW Chapter 64.34 (Condominium Act)