TCMX · Town Center Mixed Use District
Milton, WA · MMC 17.30 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Live-Work Units | HomeA ADU— | HomeA ADU— | HomeA ADU— | HomeA ADU— | — |
| Dwelling Unit, Multifamily | — | — | HomeA ADU— | HomeA ADU— | — |
| Adult Retirement Community | — | — | — | HomeA ADU— | — |
| Adult Family Homes | — | — | — | — | HomeA ADU— |
| Assisted Living Facility | — | — | — | — | HomeA ADU— |
| Dwelling Unit, Co-living | — | — | — | — | HomeA ADU— |
| Permanent Supportive Housing | — | — | — | — | HomeA ADU— |
| Transitional Housing | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 3,000 sq ft MMC 17.15A.010 | |
| Minimum lot width | 40 ft MMC 17.15A.010 | |
| Maximum density | 30 units per acre, on the net lot area MMC 17.15A.010; 17.30.050(B)(1)
for Adult Retirement Community (4+ units) Not set MMC 17.15A.010
for Adult Family Homes (group living); Assisted Living Facility (group living); Dwelling Unit, Co-living (group living) | |
| Maximum residents | Not set MMC 17.08 |
for Permanent Supportive Housing (group living); Transitional Housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft MMC 17.15B.010 | |
| Maximum front setback | ||
| Side setback | 5 ft MMC 17.15B.010 | |
| Rear setback | 0 ft MMC 17.15B.010 | |
| Maximum height | 45 ft MMC 17.15B.010 | |
| Maximum lot coverage | 90% MMC 17.15B.010 | |
| Maximum impervious surface | 90% MMC 17.15B.010 | |
| Maximum floor area ratio | 3 MMC 17.15B.010 | |
| Minimum parking | In the case of a use not specifically mentioned in this chapter, the requirement for off-street parking facilities shall be determined by the land use administrator. MMC 17.48.050 | for Dwelling Unit, Multifamily (3, 4+ units) 1 space per unit MMC 17.48.040
for Adult Retirement Community (4+ units) 0.75 spaces per unit MMC 17.48.040
for Assisted Living Facility (group living) The facility shall provide a parking plan demonstrating the facility has adequate parking to meet the expected demand from residents, staff, service providers and visitors. MMC 17.44.140(B)(5)
for Permanent Supportive Housing (group living); Transitional Housing (group living) |
| Maximum building footprint | 7,000 sq ft MMC 17.15B.010 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision MMC 16.28.050; 17.71.045 | A | 2 to 4 MMC 16.08.074; MMC 16.08.074; 16.28.020 | — | Minimum lot size 3,000 sq ft MMC 17.15A.010 Minimum lot width 40 ft MMC 17.15A.010 Minimum lot depth Not set MMC 17.15A.010 Minimum frontage Not set MMC 17.15A.010 Maximum units per lot Not set MMC 17.15A.010 |
| Subdivision MMC 16.12.020; 17.71.045 | H | 5 or more MMC 16.08.090; 16.12.010 | — | Minimum lot size 3,000 sq ft MMC 17.15A.010 Minimum lot width 40 ft MMC 17.15A.010 Minimum lot depth Not set MMC 17.15A.010 Minimum frontage Not set MMC 17.15A.010 Maximum units per lot Not set MMC 17.15A.010 |
| Unit lot subdivision (ULS) MMC 16.26.020(A) | A13 | 2 to 4 MMC 16.08.095; MMC 16.26.020(A) | — | Minimum lot size Not set MMC 16.26.030(A) Minimum lot width Not set MMC 16.26.030(A) Minimum lot depth Not set MMC 16.26.030(A) Minimum frontage Not set MMC 16.26.030(A) Maximum units per lot Not set MMC 16.26.030(A) |
| Unit lot subdivision (ULS) MMC 16.26.020(B) | H13 | 5 or more MMC 16.26.020(B) | — | Minimum lot size Not set MMC 16.26.030(A) Minimum lot width Not set MMC 16.26.030(A) Minimum lot depth Not set MMC 16.26.030(A) Minimum frontage Not set MMC 16.26.030(A) Maximum units per lot Not set MMC 16.26.030(A) |
| Binding site plan MMC 16.30.020 | H14 | 2 or more MMC 16.08.007 | — | Minimum lot size Not set MMC 16.30.030(A) Minimum lot width Not set MMC 16.30.030(A) Minimum lot depth Not set MMC 16.30.030(A) Minimum frontage Not set MMC 16.30.030(A) Maximum units per lot Not set MMC 16.30.030(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- Residential development on upper floors of a building whose first floor is used primarily for mercantile or personal and professional service establishments
- Residential units are added or constructed entirely within an existing building envelope
- Any of these is true:
- Residential development on upper floors of a building whose first floor is used primarily for mercantile or personal and professional service establishments
- Residential units are added or constructed entirely within an existing building envelope
- None of these is true:
- The adult family home receives approval under WAC 388-76-10031 or 388-76-10032 to care for up to eight adults
- The adult family home receives approval under WAC 388-76-10031 or 388-76-10032 to care for up to eight adults
- Housing type of the permanent supportive or transitional housing facility (Type I, II or III) is type_i
- Housing type of the permanent supportive or transitional housing facility (Type I, II or III) is type_ii
- Housing type of the permanent supportive or transitional housing facility (Type I, II or III) is type_iii
- None of these is true:
- The building has street-level residential uses (exempt from the build-to-line)
- The building has street-level residential uses (exempt from the build-to-line)
- Lot is within 1/2 mile of a major transit stop (RCW definition)
- All of these are true:
- Lot area is less than 6,000 sf
- Lot is within 1/2 mile of a major transit stop (RCW definition)
- All of these are true:
- Lot area is at least 6,000 sf
- Lot is within 1/2 mile of a major transit stop (RCW definition)
- No dwelling unit is stacked on another dwelling unit or other use
- The parcel is developed or planned with commercial, industrial, or condominium uses