Sign in

C-1a · Central Business District (C-1a)

Mount Vernon, WA · MVMC 17.45 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, Single-Family
Home✓1 H2 ADU✓1 ✓2
————
Dwelling, Two-Family or Duplex—
Home✓1 H2 ADU—
———
Dwelling, Multifamily——
Home✓1 H2 ADU—
Home✓1 H1 H2 ADU—
—
Permanent supportive housing facility———
Home✓3 ADU—
—
Emergency shelter for the homeless————
Home✓4 H5 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set MVMC 17.45.050(A)
35 units MVMC 17.45.030(N)
for Dwelling, Multifamily (4+ units)1
80 units MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)3
Minimum unitsNot set MVMC 17.45.030
36 units MVMC 17.45.050(A)(1)
for Dwelling, Multifamily (4+ units)1
Minimum lot sizeNo limit MVMC 17.45.070(A)
Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)3
Minimum lot widthNo limit MVMC 17.45.070(A)
Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)3
Minimum densityNot set MVMC 17.45.070
No limit MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)3
Maximum densityNo limit MVMC 17.45.070(D)
Maximum residentsan emergency shelter for the homeless shall have its occupancy set by the fire marshal and building official MVMC 17.45.030(U)

3. Building standards

StandardValueExceptions
Front setback
  • 10 ft6 MVMC 17.70.070(A)(1)(a)
  • All single-family, duplex, and multifamily buildings shall comply with the setbacks outlined within Chapter 17.70 MVMC.7 MVMC 17.45.070(B)(2); 17.70.070(A)
10 ft MVMC 17.45.050(A)(2)(a); 17.70.070(A)(2)(a)
for Dwelling, Multifamily (3, 4+ units)2
  • 25 ft7 MVMC 17.67.030(F)(1)
  • 20 ft6 MVMC 17.67.030(F)(1)
for Permanent supportive housing facility (4+ units)3
No limit MVMC 17.45.070(B)(1)
for Emergency shelter for the homeless (group living)4; Emergency shelter for the homeless (group living)5
Side setback
  • 20 ft8 MVMC 17.70.070(A)(2)(b)
  • 10 ft9 MVMC 17.70.070(A)(2)(b)
  • 15 ft10 MVMC 17.70.070(A)(2)(b)
  • All single-family, duplex, and multifamily buildings shall comply with the setbacks outlined within Chapter 17.70 MVMC.7 MVMC 17.45.070(B)(2); 17.70.070(A)
  • 5 ft6 MVMC 17.70.070(A)(1)(c)
  • All single-family, duplex, and multifamily buildings shall comply with the setbacks outlined within Chapter 17.70 MVMC.7 MVMC 17.45.070(B)(2); 17.70.070(A)
for Dwelling, Single-Family (1 unit)1; Dwelling, Single-Family (1 unit)2; Dwelling, Two-Family or Duplex (2 units)1; Dwelling, Two-Family or Duplex (2 units)2
10 ft MVMC 17.67.030(F)(2)
for Permanent supportive housing facility (4+ units)3
No limit MVMC 17.45.070(B)(1)
for Emergency shelter for the homeless (group living)4; Emergency shelter for the homeless (group living)5
Total side setbacksNot set MVMC 17.45.070
  • 15 ft11 MVMC 17.70.070(A)(1)(c)
  • Not set12 MVMC 17.70.070(A)(1)(c)
  • All single-family, duplex, and multifamily buildings shall comply with the setbacks outlined within Chapter 17.70 MVMC.7 MVMC 17.45.070(B)(2); 17.70.070(A)
for Dwelling, Single-Family (1 unit)1; Dwelling, Single-Family (1 unit)2; Dwelling, Two-Family or Duplex (2 units)1; Dwelling, Two-Family or Duplex (2 units)2
Street side setback
  • 10 ft6 MVMC 17.70.070(A)(1)(a)
  • All single-family, duplex, and multifamily buildings shall comply with the setbacks outlined within Chapter 17.70 MVMC.7 MVMC 17.45.070(B)(2); 17.70.070(A)
10 ft MVMC 17.45.050(A)(2)(a); 17.70.070(A)(2)(a)
for Dwelling, Multifamily (3, 4+ units)2
  • 25 ft7 MVMC 17.67.030(F)(1)
  • 20 ft6 MVMC 17.67.030(F)(1)
for Permanent supportive housing facility (4+ units)3
Not set MVMC 17.45.070
for Emergency shelter for the homeless (group living)4; Emergency shelter for the homeless (group living)5
Rear setback
  • 20 ft8 MVMC 17.70.070(A)(2)(b)
  • 10 ft9 MVMC 17.70.070(A)(2)(b)
  • 15 ft10 MVMC 17.70.070(A)(2)(b)
  • All single-family, duplex, and multifamily buildings shall comply with the setbacks outlined within Chapter 17.70 MVMC.7 MVMC 17.45.070(B)(2); 17.70.070(A)
  • 10 ft6 MVMC 17.70.070(A)(1)(b)
  • All single-family, duplex, and multifamily buildings shall comply with the setbacks outlined within Chapter 17.70 MVMC.7 MVMC 17.45.070(B)(2); 17.70.070(A)
for Dwelling, Single-Family (1 unit)1; Dwelling, Single-Family (1 unit)2; Dwelling, Two-Family or Duplex (2 units)1; Dwelling, Two-Family or Duplex (2 units)2
20 ft MVMC 17.67.030(F)(3)
for Permanent supportive housing facility (4+ units)3
No limit MVMC 17.45.070(B)(1)
for Emergency shelter for the homeless (group living)4; Emergency shelter for the homeless (group living)5
Maximum height
  • 25 ft13 MVMC 17.45.070(C)(3); 17.24.080
  • 35 ft14 MVMC 17.45.070(C)(3); 17.24.080
35 ft MVMC 17.45.070(C)(2); 17.15.090
for Dwelling, Single-Family (1 unit)1; Dwelling, Single-Family (1 unit)2; Dwelling, Two-Family or Duplex (2 units)1; Dwelling, Two-Family or Duplex (2 units)2
50 ft MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)3
No limit MVMC 17.45.070(C)(1)
for Emergency shelter for the homeless (group living)4; Emergency shelter for the homeless (group living)5
Maximum stories
  • 2 stories13 MVMC 17.45.070(C)(3); 17.24.080
  • 3 stories14 MVMC 17.45.070(C)(3); 17.24.080
2 stories MVMC 17.45.070(C)(2); 17.15.090
for Dwelling, Single-Family (1 unit)1; Dwelling, Single-Family (1 unit)2; Dwelling, Two-Family or Duplex (2 units)1; Dwelling, Two-Family or Duplex (2 units)2
4 stories MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)3
Not set MVMC 17.45.070
for Emergency shelter for the homeless (group living)4; Emergency shelter for the homeless (group living)5
Maximum lot coverageNot set MVMC 17.45.070(B)
  • 40%6 MVMC 17.70.070(A)(1)(f)
  • Not set7 MVMC 17.45.070(B)
for Dwelling, Single-Family (1 unit)1; Dwelling, Single-Family (1 unit)2
No limit MVMC 17.45.070(B)(1)
for Emergency shelter for the homeless (group living)4; Emergency shelter for the homeless (group living)5
Minimum parking
  • 1 space per unit15 MVMC 17.45.070(F); 17.84.030(A)
  • 1.5 spaces per unit16 MVMC 17.45.070(F); 17.84.030(A)
  • 2 spaces per unit17 MVMC 17.45.070(F); 17.84.030(A)
Not set MVMC 17.45.070(F); 17.84.030
for Dwelling, Single-Family (1 unit)1; Dwelling, Single-Family (1 unit)2; Dwelling, Two-Family or Duplex (2 units)1; Dwelling, Two-Family or Duplex (2 units)2
The number of parking spaces required to serve a PSH facility shall reflect the proposed uses for such a facility. The applicant will be required to submit a parking study documenting the number of parking spaces needed to provide parking on a site. MVMC 17.67.030(G)
for Permanent supportive housing facility (4+ units)3
(residents ÷ 10) + employees on the largest shift spaces MVMC 17.84.030(H)
for Emergency shelter for the homeless (group living)4; Emergency shelter for the homeless (group living)5
Minimum open spaceNot set MVMC 17.45.070
15% MVMC 17.67.030(I)
for Permanent supportive housing facility (4+ units)3

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit MVMC 17.73.110(B)(2)

Building

StandardValueExceptions
Front setback
  • 10 ft6 MVMC 17.70.070(A)(1)(a)
  • All single-family, duplex, and multifamily buildings shall comply with the setbacks outlined within Chapter 17.70 MVMC.7 MVMC 17.45.070(B)(2); 17.70.070(A)
Side setback
  • 5 ft6 MVMC 17.70.070(A)(1)(c)
  • All single-family, duplex, and multifamily buildings shall comply with the setbacks outlined within Chapter 17.70 MVMC.7 MVMC 17.45.070(B)(2); 17.70.070(A)
Rear setback
  • 10 ft6 MVMC 17.70.070(A)(1)(b)
  • All single-family, duplex, and multifamily buildings shall comply with the setbacks outlined within Chapter 17.70 MVMC.7 MVMC 17.45.070(B)(2); 17.70.070(A)
Maximum height35 ft MVMC 17.45.070(C)(2); 17.15.090
Maximum stories2 stories MVMC 17.45.070(C)(2); 17.15.090
Minimum parkingthe largest of 0, 3 − 0 spaces MVMC 17.73.110(B)(5); 17.45.070(F); 17.84.030
Maximum unit size1,000 sq ft MVMC 17.73.110(B)(4)
Attached to the main houseNot required MVMC 17.73.110(B)(1)
Owner lives on siteRequired MVMC 17.73.110(B)(3)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision MVMC 16.32.020(A) A up to 9 MVMC 16.04.010(D) No limit MVMC 17.45.070(D)
Minimum lot size
No limit MVMC 17.45.070(A)
Minimum lot width
No limit MVMC 17.45.070(A)
Minimum lot depth
Not set MVMC 17.45.070(A)
Minimum frontage
Not set MVMC 17.45.070(A)
Maximum units per lot
Not set MVMC 16.04.030
Subdivision MVMC 16.08.020(A) H 10 or more MVMC 16.04.010(D) No limit MVMC 17.45.070(D)
Minimum lot size
No limit MVMC 17.45.070(A)
Minimum lot width
No limit MVMC 17.45.070(A)
Minimum lot depth
Not set MVMC 17.45.070(A)
Minimum frontage
Not set MVMC 17.45.070(A)
Maximum units per lot
Not set MVMC 16.04.030
Duplex and townhouse developments creating nine (or fewer) lots, tracts or parcels MVMC 16.34.025(A); 16.32.020(A)Only for: Dwelling, Two-Family or Duplex A up to 9 MVMC 16.34.025(A) No limit MVMC 17.45.070(D)
Minimum lot size
Not set MVMC 16.34.030
Minimum lot width
20 ft MVMC 16.34.030(C)
Minimum lot depth
Not set MVMC 16.34.030
Minimum frontage
Not set MVMC 16.34.030
Maximum units per lot
1 unit MVMC 16.34.030(A)
Duplex and townhouse developments creating more than nine lots, tracts or parcels MVMC 16.34.025(B); 16.08.020(A)Only for: Dwelling, Two-Family or Duplex H 10 or more MVMC 16.34.025(B) No limit MVMC 17.45.070(D)
Minimum lot size
Not set MVMC 16.34.030
Minimum lot width
20 ft MVMC 16.34.030(C)
Minimum lot depth
Not set MVMC 16.34.030
Minimum frontage
Not set MVMC 16.34.030
Maximum units per lot
1 unit MVMC 16.34.030(A)
Binding site plan MVMC 16.40.030(A) A18 — No limit MVMC 17.45.070(D)
Minimum lot size
No limit MVMC 17.45.070(A)
Minimum lot width
No limit MVMC 17.45.070(A)
Minimum lot depth
Not set MVMC 17.45.070(A)
Minimum frontage
Not set MVMC 17.45.070(A)
Maximum units per lot
Not set MVMC 16.40.060

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The building has ground-level residential units
  2. The building has ground-level residential units
  3. All of these are true:
    • The property is within 2,640 feet (straight line from the closest property line) of three of these four facilities, each entirely within that distance - Skagit Transit service, a principal arterial road, a food resource (a retail food store of at least 12,000 gross sq ft), a service provider
    • The city has made a financial commitment to participate in the purchase of the property, or to assist with funding infrastructure improvements serving it
    • The PSH facility stays affordable to those earning 50 percent or less of the area median income for at least 50 years after its final certificate of occupancy
  4. No other emergency shelter for the homeless is within a 1,000-foot radius
  5. None of these is true:
    • No other emergency shelter for the homeless is within a 1,000-foot radius
  6. None of these is true:
    • The lot fronts an arterial street
  7. The lot fronts an arterial street
  8. All of these are true:
    • The side or rear property line is adjacent to a single-family residential zone
    None of these is true:
    • The lot fronts an arterial street
  9. All of these are true:
    • Building stories is at most 1
    None of these is true:
    • The lot fronts an arterial street
    • The side or rear property line is adjacent to a single-family residential zone
  10. All of these are true:
    • Building stories is at least 2
    None of these is true:
    • The lot fronts an arterial street
    • The side or rear property line is adjacent to a single-family residential zone
  11. All of these are true:
    • Building stories is at least 2
    None of these is true:
    • The lot fronts an arterial street
  12. All of these are true:
    • Building stories is at most 1
    None of these is true:
    • The lot fronts an arterial street
  13. None of these is true:
    • Parking is provided beneath the habitable stories
  14. Parking is provided beneath the habitable stories
  15. Bedrooms in one unit is less than 1
  16. All of these are true:
    • Bedrooms in one unit is at least 1
    • Bedrooms in one unit is less than 2
  17. Bedrooms in one unit is at least 2
  18. The land is classified for industrial or commercial use