C-1b · Central Business District (C-1b)
Mount Vernon, WA · MVMC 17.45 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, Single-Family | — | — | — | — | |
| Dwelling, Two-Family or Duplex | — | — | — | — | |
| Dwelling, Multifamily | — | — | — | ||
| Permanent supportive housing facility | — | — | — | — | |
| Emergency shelter for the homeless | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set MVMC 17.45.050(A) | 35 units MVMC 17.45.030(N)
for Dwelling, Multifamily (4+ units)1 80 units MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)3 |
| Minimum units | Not set MVMC 17.45.030 | 36 units MVMC 17.45.050(A)(1)
for Dwelling, Multifamily (4+ units)1 |
| Minimum lot size | No limit MVMC 17.45.070(A) | Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)3 |
| Minimum lot width | No limit MVMC 17.45.070(A) | Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)3 |
| Minimum density | Not set MVMC 17.45.070 | No limit MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)3 |
| Maximum density | No limit MVMC 17.45.070(D) | |
| Maximum residents | an emergency shelter for the homeless shall have its occupancy set by the fire marshal and building official MVMC 17.45.030(U) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft MVMC 17.45.050(A)(2)(a); 17.70.070(A)(2)(a)
for Dwelling, Multifamily (3, 4+ units)2 for Permanent supportive housing facility (4+ units)3 | |
| Side setback | 10 ft MVMC 17.67.030(F)(2)
for Permanent supportive housing facility (4+ units)3 | |
| Total side setbacks | Not set MVMC 17.45.070 | |
| Street side setback | 10 ft MVMC 17.45.050(A)(2)(a); 17.70.070(A)(2)(a)
for Dwelling, Multifamily (3, 4+ units)2 for Permanent supportive housing facility (4+ units)3 | |
| Rear setback | 20 ft MVMC 17.67.030(F)(3)
for Permanent supportive housing facility (4+ units)3 | |
| Maximum height | 35 ft MVMC 17.45.070(C)(2); 17.15.090
50 ft MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)3 | |
| Maximum stories | 2 stories MVMC 17.45.070(C)(2); 17.15.090
4 stories MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)3 | |
| Maximum lot coverage | Not set MVMC 17.45.070(B) | |
| Minimum parking | Not set MVMC 17.45.070(F); 17.84.030
The number of parking spaces required to serve a PSH facility shall reflect the proposed uses for such a facility. The applicant will be required to submit a parking study documenting the number of parking spaces needed to provide parking on a site. MVMC 17.67.030(G)
for Permanent supportive housing facility (4+ units)3 | |
| Minimum open space | Not set MVMC 17.45.070 | 15% MVMC 17.67.030(I)
for Permanent supportive housing facility (4+ units)3 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit MVMC 17.73.110(B)(2) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | 35 ft MVMC 17.45.070(C)(2); 17.15.090 | |
| Maximum stories | 2 stories MVMC 17.45.070(C)(2); 17.15.090 | |
| Minimum parking | the largest of 0, 3 − 0 spaces MVMC 17.73.110(B)(5); 17.45.070(F); 17.84.030 | |
| Maximum unit size | 1,000 sq ft MVMC 17.73.110(B)(4) | |
| Attached to the main house | Not required MVMC 17.73.110(B)(1) | |
| Owner lives on site | Required MVMC 17.73.110(B)(3) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision MVMC 16.32.020(A) | A | up to 9 MVMC 16.04.010(D) | No limit MVMC 17.45.070(D) | Minimum lot size No limit MVMC 17.45.070(A) Minimum lot width No limit MVMC 17.45.070(A) Minimum lot depth Not set MVMC 17.45.070(A) Minimum frontage Not set MVMC 17.45.070(A) Maximum units per lot Not set MVMC 16.04.030 |
| Subdivision MVMC 16.08.020(A) | H | 10 or more MVMC 16.04.010(D) | No limit MVMC 17.45.070(D) | Minimum lot size No limit MVMC 17.45.070(A) Minimum lot width No limit MVMC 17.45.070(A) Minimum lot depth Not set MVMC 17.45.070(A) Minimum frontage Not set MVMC 17.45.070(A) Maximum units per lot Not set MVMC 16.04.030 |
| Duplex and townhouse developments creating nine (or fewer) lots, tracts or parcels MVMC 16.34.025(A); 16.32.020(A)Only for: Dwelling, Two-Family or Duplex | A | up to 9 MVMC 16.34.025(A) | No limit MVMC 17.45.070(D) | Minimum lot size Not set MVMC 16.34.030 Minimum lot width 20 ft MVMC 16.34.030(C) Minimum lot depth Not set MVMC 16.34.030 Minimum frontage Not set MVMC 16.34.030 Maximum units per lot 1 unit MVMC 16.34.030(A) |
| Duplex and townhouse developments creating more than nine lots, tracts or parcels MVMC 16.34.025(B); 16.08.020(A)Only for: Dwelling, Two-Family or Duplex | H | 10 or more MVMC 16.34.025(B) | No limit MVMC 17.45.070(D) | Minimum lot size Not set MVMC 16.34.030 Minimum lot width 20 ft MVMC 16.34.030(C) Minimum lot depth Not set MVMC 16.34.030 Minimum frontage Not set MVMC 16.34.030 Maximum units per lot 1 unit MVMC 16.34.030(A) |
| Binding site plan MVMC 16.40.030(A) | A18 | — | No limit MVMC 17.45.070(D) | Minimum lot size No limit MVMC 17.45.070(A) Minimum lot width No limit MVMC 17.45.070(A) Minimum lot depth Not set MVMC 17.45.070(A) Minimum frontage Not set MVMC 17.45.070(A) Maximum units per lot Not set MVMC 16.40.060 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The building has ground-level residential units
- The building has ground-level residential units
- All of these are true:
- The property is within 2,640 feet (straight line from the closest property line) of three of these four facilities, each entirely within that distance - Skagit Transit service, a principal arterial road, a food resource (a retail food store of at least 12,000 gross sq ft), a service provider
- The city has made a financial commitment to participate in the purchase of the property, or to assist with funding infrastructure improvements serving it
- The PSH facility stays affordable to those earning 50 percent or less of the area median income for at least 50 years after its final certificate of occupancy
- No other emergency shelter for the homeless is within a 1,000-foot radius
- None of these is true:
- No other emergency shelter for the homeless is within a 1,000-foot radius
- None of these is true:
- The lot fronts an arterial street
- The lot fronts an arterial street
- All of these are true:
- The side or rear property line is adjacent to a single-family residential zone
- The lot fronts an arterial street
- All of these are true:
- Building stories is at most 1
- The lot fronts an arterial street
- The side or rear property line is adjacent to a single-family residential zone
- All of these are true:
- Building stories is at least 2
- The lot fronts an arterial street
- The side or rear property line is adjacent to a single-family residential zone
- All of these are true:
- Building stories is at least 2
- The lot fronts an arterial street
- All of these are true:
- Building stories is at most 1
- The lot fronts an arterial street
- None of these is true:
- Parking is provided beneath the habitable stories
- Parking is provided beneath the habitable stories
- Bedrooms in one unit is less than 1
- All of these are true:
- Bedrooms in one unit is at least 1
- Bedrooms in one unit is less than 2
- Bedrooms in one unit is at least 2
- The land is classified for industrial or commercial use