Sign in

C-3 · Community Commercial District (C-3)

Mount Vernon, WA · MVMC 17.51 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, Multifamily——
HomeH1 ADU—
HomeH1 ADU—
—
Permanent supportive housing facility———
Home✓2 ADU—
—
Emergency shelter for the homeless————
Home✓3 H4 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set MVMC 17.51.040(A)
80 units MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)2
Minimum lot sizeNo limit MVMC 17.51.050
Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)2
Minimum lot widthNo limit MVMC 17.51.050
Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)2
Minimum densityNot set MVMC 17.51.040(A)(3)
No limit MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)2
Maximum densityNo limit MVMC 17.51.040(A)(3)(b)
Not set MVMC 17.51.050
for Emergency shelter for the homeless (group living)3; Emergency shelter for the homeless (group living)4
Maximum residentsan emergency shelter for the homeless shall have 100 square feet of gross floor area per resident as defined by the city building code (MVMC Title 15) MVMC 17.51.020(E)

3. Building standards

StandardValueExceptions
Front setback
  • 25 ft5 MVMC 17.51.060(A)
  • 10 ft6 MVMC 17.51.060(A)
  • 25 ft5 MVMC 17.67.030(F)(1)
  • 20 ft6 MVMC 17.67.030(F)(1)
for Permanent supportive housing facility (4+ units)2
Side setback
  • 20 ft7 MVMC 17.51.060(B)
  • 10 ft8 MVMC 17.51.060(B)
  • 0 ft9 MVMC 17.51.060(B)
10 ft MVMC 17.67.030(F)(2)
for Permanent supportive housing facility (4+ units)2
Street side setback
  • 25 ft5 MVMC 17.51.060(A)
  • 10 ft6 MVMC 17.51.060(A)
  • 25 ft5 MVMC 17.67.030(F)(1)
  • 20 ft6 MVMC 17.67.030(F)(1)
for Permanent supportive housing facility (4+ units)2
Rear setback
  • 20 ft7 MVMC 17.51.060(B)
  • 10 ft8 MVMC 17.51.060(B)
  • 0 ft9 MVMC 17.51.060(B)
20 ft MVMC 17.67.030(F)(3)
for Permanent supportive housing facility (4+ units)2
Building separationNot set MVMC 17.67.030
10 ft MVMC 17.51.040(A)(3)(a)
for Dwelling, Multifamily (3, 4+ units)1
Maximum height
  • 50 ft10 MVMC 17.51.070
  • 65 ft11 MVMC 17.51.070
50 ft MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)2
Maximum stories
  • 4 stories10 MVMC 17.51.070
  • 6 stories12 MVMC 17.51.070
  • 5 stories13 MVMC 17.51.070; 17.73.070
4 stories MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)2
Minimum parking
  • 1 space per unit14 MVMC 17.51.040(A)(3)(d); 17.51.090; 17.84.030(A)
  • 1.5 spaces per unit15 MVMC 17.51.040(A)(3)(d); 17.51.090; 17.84.030(A)
  • 2 spaces per unit16 MVMC 17.51.040(A)(3)(d); 17.51.090; 17.84.030(A)
The number of parking spaces required to serve a PSH facility shall reflect the proposed uses for such a facility. The applicant will be required to submit a parking study documenting the number of parking spaces needed to provide parking on a site. MVMC 17.67.030(G)
for Permanent supportive housing facility (4+ units)2
(residents ÷ 10) + employees on the largest shift spaces MVMC 17.51.090; 17.84.030(H)
for Emergency shelter for the homeless (group living)3; Emergency shelter for the homeless (group living)4
Minimum open spaceNot set MVMC 17.51.040(A)
15% MVMC 17.67.030(I)
for Permanent supportive housing facility (4+ units)2

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision MVMC 16.32.020(A) A up to 9 MVMC 16.04.010(D) No limit MVMC 17.51.040(A)(3)(b)
Minimum lot size
No limit MVMC 17.51.050
Minimum lot width
No limit MVMC 17.51.050
Minimum lot depth
Not set MVMC 17.51.050
Minimum frontage
Not set MVMC 17.51.050
Maximum units per lot
Not set MVMC 16.04.030
Subdivision MVMC 16.08.020(A) H 10 or more MVMC 16.04.010(D) No limit MVMC 17.51.040(A)(3)(b)
Minimum lot size
No limit MVMC 17.51.050
Minimum lot width
No limit MVMC 17.51.050
Minimum lot depth
Not set MVMC 17.51.050
Minimum frontage
Not set MVMC 17.51.050
Maximum units per lot
Not set MVMC 16.04.030
Binding site plan MVMC 16.40.030(A) A17 — Not set MVMC 17.51.050
Minimum lot size
No limit MVMC 17.51.050
Minimum lot width
No limit MVMC 17.51.050
Minimum lot depth
Not set MVMC 17.51.050
Minimum frontage
Not set MVMC 17.51.050
Maximum units per lot
Not set MVMC 16.40.060

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The multifamily use is not constructed on the ground floor
    • The ground floor uses include one or more of the zone's permitted uses
    • The multifamily uses are built at the same time as or after the nonresidential ground floor uses
  2. All of these are true:
    • The property is within 2,640 feet (straight line from the closest property line) of three of these four facilities, each entirely within that distance - Skagit Transit service, a principal arterial road, a food resource (a retail food store of at least 12,000 gross sq ft), a service provider
    • The city has made a financial commitment to participate in the purchase of the property, or to assist with funding infrastructure improvements serving it
    • The PSH facility stays affordable to those earning 50 percent or less of the area median income for at least 50 years after its final certificate of occupancy
  3. No other emergency shelter for the homeless is within a 1,000-foot radius
  4. None of these is true:
    • No other emergency shelter for the homeless is within a 1,000-foot radius
  5. The lot fronts an arterial street
  6. None of these is true:
    • The lot fronts an arterial street
  7. The property line adjoins a single-family district or use, with no intervening street or alley
  8. All of these are true:
    • The property line adjoins a multifamily district or use, with no intervening street or alley
    None of these is true:
    • The property line adjoins a single-family district or use, with no intervening street or alley
  9. None of these is true:
    • The property line adjoins a single-family district or use, with no intervening street or alley
    • The property line adjoins a multifamily district or use, with no intervening street or alley
  10. None of these is true:
    • Parking is provided beneath the habitable stories
    • Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
  11. Any of these is true:
    • Parking is provided beneath the habitable stories
    • Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
  12. Parking is provided beneath the habitable stories
  13. All of these are true:
    • Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
    None of these is true:
    • Parking is provided beneath the habitable stories
  14. Bedrooms in one unit is less than 1
  15. All of these are true:
    • Bedrooms in one unit is at least 1
    • Bedrooms in one unit is less than 2
  16. Bedrooms in one unit is at least 2
  17. The land is classified for industrial or commercial use