L-C · Limited Commercial (LC)
Mount Vernon, WA · MVMC 17.42 · Official code
By right: 1 unit, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, Single-Family | Home✓ ADU✓ | — | — | — | — |
| Dwelling, Multifamily | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Permanent supportive housing facility | — | — | — | — | |
| Specialized housing for the elderly | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 15 units MVMC 17.42.020(B) | Not set MVMC 17.42.040
for Dwelling, Multifamily (4+ units) 80 units MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)1 |
| Minimum units | Not set MVMC 17.42.020 | 16 units MVMC 17.42.040(C)
for Dwelling, Multifamily (4+ units) |
| Minimum lot size | 6,000 sq ft MVMC 17.42.050 | Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)1 |
| Minimum lot width | 60 ft MVMC 17.42.050 | Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)1 |
| Minimum lot depth | Not set MVMC 17.42.050 | 80 ft MVMC 17.42.020(B); 17.24.050(B)
for Dwelling, Multifamily (3, 4+ units) |
| Minimum frontage | Not set MVMC 17.42.050 | 30 ft MVMC 17.42.020(B); 17.24.050(B)
for Dwelling, Multifamily (3, 4+ units) |
| Minimum density | 10 units per acre MVMC 17.42.020(B); 17.24.010 | Not set MVMC 17.42.050
No limit MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)1 |
| Maximum density | Not set MVMC 17.42.050
No limit MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)1 | |
| Maximum sleeping units | 15 sleeping units MVMC 17.42.040(B) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft MVMC 17.42.060(A)
| |
| Side setback | 10 ft MVMC 17.42.020(B); 17.24.060(B) | 5 ft MVMC 17.42.060(B)
|
| Street side setback | Not set MVMC 17.42.060
| |
| Rear setback | 20 ft MVMC 17.42.060(C) | |
| Building separation | Not set MVMC 17.42.060 | 10 ft MVMC 17.42.020(B); 17.24.090
for Dwelling, Multifamily (3, 4+ units) |
| Maximum height | 35 ft MVMC 17.42.080
50 ft MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)1 | |
| Maximum stories | Not set MVMC 17.42.060
4 stories MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)1 | |
| Maximum lot coverage | 40% MVMC 17.42.070 | Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)1 |
| Minimum parking | Not set MVMC 17.42.110; 17.84.030
for Dwelling, Single-Family (1 unit) The number of parking spaces required to serve a PSH facility shall reflect the proposed uses for such a facility. The applicant will be required to submit a parking study documenting the number of parking spaces needed to provide parking on a site. MVMC 17.67.030(G)
for Permanent supportive housing facility (4+ units)1 (beds in the project ÷ 5) + employees on the largest shift spaces MVMC 17.84.030(K)
for Specialized housing for the elderly (group living)2 | |
| Minimum open space | Not set MVMC 17.42.060 | 15% MVMC 17.67.030(I)
for Permanent supportive housing facility (4+ units)1 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit MVMC 17.73.110(B)(2) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft MVMC 17.42.060(A) | |
| Side setback | 5 ft MVMC 17.42.060(B) | |
| Rear setback | 20 ft MVMC 17.42.060(C) | |
| Maximum height | 35 ft MVMC 17.42.080 | |
| Minimum parking | the largest of 0, 3 − 0 spaces MVMC 17.73.110(B)(5); 17.42.110; 17.84.030 | |
| Maximum unit size | 1,000 sq ft MVMC 17.73.110(B)(4) | |
| Attached to the main house | Not required MVMC 17.73.110(B)(1) | |
| Owner lives on site | Required MVMC 17.73.110(B)(3) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision MVMC 16.32.020(A) | A | up to 9 MVMC 16.04.010(D) | Not set MVMC 17.42.050 | Minimum lot size 6,000 sq ft MVMC 17.42.050 Minimum lot width 60 ft MVMC 17.42.050 Minimum lot depth Not set MVMC 17.42.050 Minimum frontage Not set MVMC 17.42.050 Maximum units per lot Not set MVMC 16.04.030 |
| Subdivision MVMC 16.08.020(A) | H | 10 or more MVMC 16.04.010(D) | Not set MVMC 17.42.050 | Minimum lot size 6,000 sq ft MVMC 17.42.050 Minimum lot width 60 ft MVMC 17.42.050 Minimum lot depth Not set MVMC 17.42.050 Minimum frontage Not set MVMC 17.42.050 Maximum units per lot Not set MVMC 16.04.030 |
| Binding site plan MVMC 16.40.030(A) | A12 | — | Not set MVMC 17.42.050 | Minimum lot size 6,000 sq ft MVMC 16.40.060(A); 17.42.050 Minimum lot width 60 ft MVMC 16.40.060(A); 17.42.050 Minimum lot depth Not set MVMC 16.40.060(A); 17.42.050 Minimum frontage Not set MVMC 16.40.060(A); 17.42.050 Maximum units per lot Not set MVMC 16.40.060 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The property is within 2,640 feet (straight line from the closest property line) of three of these four facilities, each entirely within that distance - Skagit Transit service, a principal arterial road, a food resource (a retail food store of at least 12,000 gross sq ft), a service provider
- The city has made a financial commitment to participate in the purchase of the property, or to assist with funding infrastructure improvements serving it
- The PSH facility stays affordable to those earning 50 percent or less of the area median income for at least 50 years after its final certificate of occupancy
- Floor area of all units is at most 10,000
- None of these is true:
- At least 50 percent of the required parking spaces are located in an enclosed area beneath the habitable floors of the building or complex
- At least 50 percent of the required parking spaces are located in an enclosed area beneath the habitable floors of the building or complex
- The lot fronts an arterial street
- None of these is true:
- The lot fronts an arterial street
- None of these is true:
- Parking is provided beneath the habitable stories
- Parking is provided beneath the habitable stories
- Bedrooms in one unit is less than 1
- All of these are true:
- Bedrooms in one unit is at least 1
- Bedrooms in one unit is less than 2
- Bedrooms in one unit is at least 2
- The land is classified for industrial or commercial use