Sign in

SDD C/R · Special Development District Commercial/Residential (SDD C/R)

Mountlake Terrace, WA · MTMC 19.85 · Official code

By right: 1 unit · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling unit, single
Home✓ ADU—
————
Dwelling unit, multi-household—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Adult care household————
Home✓ ADU—
Assisted living————
Home✓ ADU—
Long-term care facility————
Home✓ ADU—
Group homes————
HomeH2 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size5,400 sq ft MTMC 19.85.030
Minimum frontage40 ft MTMC 19.85.030
Maximum residentsNot set MTMC 19.85.030
6 persons MTMC 19.15.020
for Adult care household (group living)

3. Building standards

StandardValueExceptions
Front setback15 ft MTMC 19.85.030
Side setback
  • 0 ft3 MTMC 19.85.030
  • 10 ft4 MTMC 19.85.030
Rear setback
  • 0 ft3 MTMC 19.85.030
  • 25 ft4 MTMC 19.85.030
Maximum height35 ft MTMC 19.85.030
Maximum stories3 stories MTMC 19.85.030
Maximum lot coverage40% MTMC 19.85.030
Minimum parking
  • 1.25 spaces per unit5 MTMC 19.85.040(D)
  • 1.25 + (bedrooms in one unit − 2) spaces per unit6 MTMC 19.85.040(D)
1 space per unit MTMC 19.125.120(A)
for Dwelling unit, single (1 unit); Adult care household (group living)
For any use that does not clearly match with a more general function listed in said table or for any specific use that has special characteristics that may require a different amount of parking than would typically be needed by the more general function, as either is determined by the Director, a parking study shall be required; provided, that, as an alternative, the Director may require the development to provide a certain amount of parking spaces for the specific function or use based on nationally accepted standards. MTMC 19.125.120(A)(1)
for Assisted living (group living); Long-term care facility (group living); Group homes (group living)2

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision MTMC 17.03.020; 18.05.070 A up to 9 MTMC 17.03.010; 17.01.020 —
Minimum lot size
5,400 sq ft MTMC 19.85.030
Minimum frontage
40 ft MTMC 19.85.030
Subdivision MTMC 17.04.020; 18.05.070 H 10 or more MTMC 17.04.010; 17.01.020 —
Minimum lot size
5,400 sq ft MTMC 19.85.030
Minimum frontage
40 ft MTMC 19.85.030
Binding site plan MTMC 17.05.020; 18.05.070 A
Maximum lots
Not set MTMC 17.05.010
—
Minimum lot size
No limit MTMC 19.85.040(F)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Housing is part of a mixed commercial/residential development
  2. The use is established as an essential public facility under Chapter 18.15 MTMC
  3. The side or rear property line is adjacent to a developed commercial use
  4. None of these is true:
    • The side or rear property line is adjacent to a developed commercial use
  5. Bedrooms in one unit is at most 2
  6. Bedrooms in one unit is more than 2