R1 · R-1 – Single-family residential zone
Moxee, WA · MMC 16.25.080; Table 16.30.010; Table 16.35.160 · Official code
By right: 1 unit · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| SF: Detached home | Home✓ ADU— | — | — | — | — |
| SF: Factory-built home | Home✓ ADU— | — | — | — | — |
| SF: Manufactured home on individual lot | — | — | — | — | |
| Adult family home | — | — | — | — | Home✓ ADU— |
| Group home | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 7,000 sq ft MMC Table 16.35.160 | |
| Minimum lot width | 60 ft MMC Table 16.35.160 | |
| Maximum density | 6 units per acre, a fraction of 0.5 or more rounds up MMC Table 16.35.160; 16.35.050(2) | Not set MMC Table 16.35.160; 16.35.050(2)
for Adult family home (group living); Group home (group living) |
| Maximum residents | 6 persons MMC 16.10.010; 16.35.070(3)(d) | Not set MMC 16.10
for Group home (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft MMC Table 16.35.160 | |
| Side setback | ||
| Rear setback | 15 ft MMC Table 16.35.160 | |
| Maximum height | 35 ft MMC Table 16.35.160; 16.35.040(2)(a) | |
| Maximum impervious surface | 50% MMC Table 16.35.160 note 3; 16.35.030 | |
| Minimum parking | 2 spaces per unit MMC Table 16.50.060 | Off-street parking requirements for uses not specifically listed in Table 16.50.060 shall be determined by the administrative official using Level 1 review based upon the requirement for similar uses. MMC 16.50.050(7)
for Adult family home (group living); Group home (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short plat MMC 16.60.090(1)(b); 16.60.080(4) | A | Minimum lots Not set MMC 16.60.080 Maximum lots 9 lots MMC 16.60.080(1); 16.10.190 |
— | Minimum lot size Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum lot width Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum lot depth Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum frontage Every lot shall be provided with frontage on a public street or approved private lane, as provided in MMC 16.60.590, connecting to an existing public street. MMC 16.60.550(2)(c)(i) Maximum units per lot Not set MMC 16.60.550 |
| Subdivision MMC 16.60.150(2); 16.60.180 | H | Minimum lots 10 lots MMC 16.10.190; 16.60.140(1) Maximum lots Not set MMC 16.60.140 |
— | Minimum lot size Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum lot width Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum lot depth Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum frontage Every lot shall be provided with frontage on a public street or approved private lane, as provided in MMC 16.60.590, connecting to an existing public street. MMC 16.60.550(2)(c)(i) Maximum units per lot Not set MMC 16.60.550 |
| Manufactured home subdivision MMC 16.60.150(2); 16.60.180Only for: SF: Manufactured home on individual lot | H | — | 6 units per acre, a fraction of 0.5 or more rounds up MMC Table 16.35.160; 16.35.050(2) | Minimum lot size 7,000 sq ft MMC Table 16.35.160 Minimum lot width 60 ft MMC Table 16.35.160 Maximum units per lot 1 unit MMC 16.10.130; MMC Table 16.35.160 |
| Planned development – residential MMC Table 16.30.010; 16.60.400 | H | — |
Area taken out for roads and utilities 25% MMC 16.60.350(2) |
Minimum lot size All zoning and subdivision requirements may be modified in a planned development in the interest of the expressed purposes above, except: (1) Permitted uses; (2) Street setbacks on exterior streets (i.e., the perimeters of the planned development district) as specified in the applicable zone designation; (3) Surveying standards; and (4) Engineering design and construction standards of public improvements but not including street right-of-way width. MMC 16.60.320 Minimum lot width All zoning and subdivision requirements may be modified in a planned development in the interest of the expressed purposes above, except: (1) Permitted uses; (2) Street setbacks on exterior streets (i.e., the perimeters of the planned development district) as specified in the applicable zone designation; (3) Surveying standards; and (4) Engineering design and construction standards of public improvements but not including street right-of-way width. MMC 16.60.320 Minimum lot depth All zoning and subdivision requirements may be modified in a planned development in the interest of the expressed purposes above, except: (1) Permitted uses; (2) Street setbacks on exterior streets (i.e., the perimeters of the planned development district) as specified in the applicable zone designation; (3) Surveying standards; and (4) Engineering design and construction standards of public improvements but not including street right-of-way width. MMC 16.60.320 Minimum frontage All zoning and subdivision requirements may be modified in a planned development in the interest of the expressed purposes above, except: (1) Permitted uses; (2) Street setbacks on exterior streets (i.e., the perimeters of the planned development district) as specified in the applicable zone designation; (3) Surveying standards; and (4) Engineering design and construction standards of public improvements but not including street right-of-way width. MMC 16.60.320 Maximum units per lot All zoning and subdivision requirements may be modified in a planned development in the interest of the expressed purposes above, except: (1) Permitted uses; (2) Street setbacks on exterior streets (i.e., the perimeters of the planned development district) as specified in the applicable zone designation; (3) Surveying standards; and (4) Engineering design and construction standards of public improvements but not including street right-of-way width. MMC 16.60.320 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The manufactured home is new and previously untitled and bears the Washington State or HUD insignia
- Lot width is less than 56 ft
- All of these are true:
- Lot width is at least 56 ft
- Lot width is less than 66 ft
- All of these are true:
- Lot width is at least 66 ft
- Lot width is less than 76 ft
- All of these are true:
- Lot width is at least 76 ft
- Lot width is less than 86 ft
- Lot width is at least 86 ft
- None of these is true:
- The planned development makes large scale common area improvements and takes the full 20 percent density bonus
- The planned development makes large scale common area improvements and takes the full 20 percent density bonus