Sign in

MUR · Mixed Use Residential

Newcastle, WA · NMC 18.08.030; 18.12.040 · Official code

By right: 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Senior citizen, assisted—
HomeH ADU—
HomeH ADU—
HomeH ADU—
—
Townhouse——
Home✓ ADU—
Home✓ ADU—
—
Fourplex———
Home✓ ADU—
—
Fiveplex———
Home✓ ADU—
—
Sixplex———
Home✓ ADU—
—
Multifamily———
Home✓ ADU—
—
Adult family home————
Home✓ ADU—
Community residential facility-I————
HomeH ADU—
Community residential facility-II————
HomeH ADU—
Co-living housing————
Home✓ ADU—
Dormitory————
HomeH1 ADU—
Indoor emergency shelters————
Home✓ ADU—
Indoor emergency housing————
Home✓ ADU—
Transitional housing————
Home✓ ADU—
Permanent supportive housing————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set NMC 18.12.040A
4 units NMC 18.06.060
for Fourplex (4+ units)
5 units NMC 18.06.060
for Fiveplex (4+ units)
6 units NMC 18.06.190
for Sixplex (4+ units)
Minimum unitsNot set NMC 18.12.040A
4 units NMC 18.06.060
for Fourplex (4+ units)
5 units NMC 18.06.060
for Fiveplex (4+ units)
6 units NMC 18.06.190
for Sixplex (4+ units)
7 units NMC 18.06.130
for Multifamily (4+ units)
Maximum residentsNot set NMC 18.06.030
6 persons NMC 18.06.010
for Adult family home (group living)
10 persons NMC 18.06.030
for Community residential facility-I (group living)

3. Building standards

StandardValueExceptions
Side setback
  • 20 ft2 NMC 18.12.040A; 18.12.040B.7
  • 10 ft3 NMC 18.12.040B.8
Rear setback
  • 20 ft2 NMC 18.12.040A
  • 0 ft3 NMC 18.12.040B.7
Maximum height
  • 75 ft4 NMC 18.12.040B.4
  • 65 ft5 NMC 18.12.040A
Maximum lot coverage70% NMC 18.12.040A
Maximum impervious surface75% NMC 18.12.040A
Maximum floor area ratio
  • 46 NMC 18.12.040B.10
  • 17 NMC 18.12.040B.10
  • 15 NMC 18.12.040A
Minimum parking
  • 0 spaces per unit8 NMC 18.18.035B.1
  • 1 space per unit9 NMC 18.18.035B.2
  • 2 spaces per unit10 NMC 18.18.035B.3
main dwelling units on the lot ÷ 3 spaces NMC 18.18.030F
for Senior citizen, assisted (2, 3, 4+ units)
  • 1 + ((main dwelling units on the lot ÷ 10, rounded up) ÷ main dwelling units on the lot) spaces per unit11 NMC 18.18.030F
  • 1.5 + ((main dwelling units on the lot ÷ 10, rounded up) ÷ main dwelling units on the lot) spaces per unit12 NMC 18.18.030F
  • 2 + ((main dwelling units on the lot ÷ 10, rounded up) ÷ main dwelling units on the lot) spaces per unit13 NMC 18.18.030F
for Multifamily (4+ units)
Not set NMC 18.18.030F
for Adult family home (group living); Indoor emergency shelters (group living); Indoor emergency housing (group living); Transitional housing (group living); Permanent supportive housing (group living)
bedrooms in the whole project ÷ 2 spaces NMC 18.18.030F
for Community residential facility-I (group living); Community residential facility-II (group living); Dormitory (group living)1
  • 0 spaces per unit14 NMC 18.18.030F
  • 0.25 spaces per unit15 NMC 18.18.030F
for Co-living housing (group living)
Minimum open space20% NMC 18.12.180

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision, short NMC 20.03.020 A up to 9 NMC 20.01.020 —
Minimum lot size
Not set NMC 18.12.040A
Subdivision NMC 20.04.020 H 10 or more NMC 18.06.190 —
Minimum lot size
Not set NMC 18.12.040A
Unit lot subdivision NMC 20.09.020; 20.03.020Only for: Townhouse, Fourplex, Fiveplex, Sixplex A16 —
Maximum units
9 units NMC 20.09.020
Minimum lot size
No limit NMC 20.09.030B
Minimum lot width
No limit NMC 20.09.030B
Unit lot subdivision NMC 20.09.020; 20.04.020Only for: Townhouse, Fourplex, Fiveplex, Sixplex H17 —
Maximum units
No limit NMC 20.09.020
Minimum lot size
No limit NMC 20.09.030B
Minimum lot width
No limit NMC 20.09.030B
Binding site plan NMC 20.05.020 A18
Maximum lots
Not set NMC 20.05.010
—
Minimum lot size
Not set NMC 18.12.040A

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The use is an accessory to a school, college/university or church
  2. The property line adjoins a single-family residential zone
  3. None of these is true:
    • The property line adjoins a single-family residential zone
  4. Lot is within the community business center (CBC) overlay zone
  5. None of these is true:
    • Lot is within the community business center (CBC) overlay zone
  6. All of these are true:
    • Lot is within the community business center (CBC) overlay zone
    • The project uses FAR incentives to go above a 1:1 FAR in the CBC overlay zone
  7. All of these are true:
    • Lot is within the community business center (CBC) overlay zone
    None of these is true:
    • The project uses FAR incentives to go above a 1:1 FAR in the CBC overlay zone
  8. Lot is within one-half mile walking distance of a major transit stop
  9. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  10. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  11. Bedrooms in one unit is at most 1
  12. Bedrooms in one unit is 2
  13. Bedrooms in one unit is at least 3
  14. Co-living housing is less than 0.5 mile of a major transit stop
  15. None of these is true:
    • Co-living housing is less than 0.5 mile of a major transit stop
  16. Main dwelling units on the lot is at most 9
  17. All of these are true:
    • Main dwelling units on the lot is more than 9
    • The unit lot subdivision is combined with a planned unit development or development agreement
  18. Any of these is true:
    • Land is divided for sale or lease of commercially or industrially zoned property
    • A portion or all of the land will be subject to the procedures for condominiums in Chapter 64.32 or 64.34 RCW