Sign in

R-5 · Residential Low Density; Multifamily

Normandy Park, WA · NPMC 18.28 · Official code

By right: 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling unit – duplex—
Home✓ ADU—
———
Churches, church purposes, use with affordable housing (Chapter 18.105 NPMC)—
HomeH1 ADU—
HomeH1 ADU—
HomeH1 ADU—
—
Court-type apartments or multiple dwelling units containing no more than four dwelling units——
Home✓ ADU—
Home✓ ADU—
—
Transitional housing————
Home✓2 ADU—
Permanent supportive housing————
HomeH2 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units4 units NPMC 18.28.020(1)
Not set NPMC 18.105.050(5)(c)
for Churches, church purposes, use with affordable housing (Chapter 18.105 NPMC) (4+ units)1
Minimum lot size5,000 × main dwelling units on the lot sq ft NPMC 18.28.060(2)
No limit NPMC 18.105.050(5)(d)
for Churches, church purposes, use with affordable housing (Chapter 18.105 NPMC) (2, 3, 4+ units)1
5,000 sq ft NPMC 18.15.020
for Transitional housing (group living)2; Permanent supportive housing (group living)2
Minimum lot widthNo limit NPMC 18.15.010(2)
Minimum lot depthNo limit NPMC 18.15.010(2)
Minimum frontage25 ft NPMC 17.40.020
Maximum density8 units per acre NPMC 18.15.020
Not set NPMC 18.15.020
for Transitional housing (group living)2; Permanent supportive housing (group living)2
Maximum residents10 persons NPMC 18.44.090(1)

3. Building standards

StandardValueExceptions
Front setback20 ft NPMC 18.15.020
Side setback10 ft NPMC 18.15.020
Street side setbackNo limit NPMC 18.15.010(2)
Rear setback25 ft NPMC 18.15.020
Maximum height25 ft NPMC 18.24.020(1); 18.15.020 note 31
Maximum lot coverageNo limit NPMC 18.15.010(2)
Maximum floor area ratio0.35 NPMC 18.15.020
Minimum parking1 + (the largest of bedrooms in one unit − 3, 0) spaces per unit NPMC 18.25.020(2) Chart 18.25.020a
Affordable housing: TBD through development agreement (Chapter 18.105 NPMC) NPMC 18.25.020(2) Chart 18.25.020a; 18.25.020(7)
for Churches, church purposes, use with affordable housing (Chapter 18.105 NPMC) (2, 3, 4+ units)1
Minimum open spaceNo limit NPMC 18.15.010(2)
Maximum units per building4 units NPMC 18.28.060(1)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision NPMC 17.12.010; 18.150.030(4) A up to 4 NPMC 17.12.020(2) —
Minimum lot size
5,000 sq ft NPMC 18.15.020
Minimum lot width
No limit NPMC 18.15.010(2)
Minimum lot depth
No limit NPMC 18.15.010(2)
Minimum frontage
25 ft NPMC 17.12.010(4)
Plat NPMC 17.16.090; 18.150.030(4) H 5 or more NPMC 17.16.010 —
Minimum lot size
5,000 sq ft NPMC 18.15.020
Minimum lot width
No limit NPMC 18.15.010(2)
Minimum lot depth
No limit NPMC 18.15.010(2)
Minimum frontage
25 ft NPMC 17.40.020
Binding site plan NPMC 17.54.020(1); 18.150.030(4) H3
Maximum lots
Not set NPMC 17.54.030
—
Minimum lot size
Not set NPMC 17.54.030
Minimum lot width
Not set NPMC 17.54.030
Minimum lot depth
Not set NPMC 17.54.030
Minimum frontage
25 ft NPMC 17.40.020

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The site is accessed from a major arterial
    • The property is owned by a religious organization
  2. All of these are true:
    • Within one-half-mile walking distance of a bus transit stop
    None of these is true:
    • Within a mile of another property with permanent supportive housing, transitional housing, emergency shelter or emergency housing
  3. The division creates condominium units