Sign in

RM-1800 · Residential Medium High Density; Multifamily

Normandy Park, WA · NPMC 18.15.040 · Official code

By right: 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling unit – duplex—
Home✓ ADU—
———
Churches, church purposes, use with affordable housing (Chapter 18.105 NPMC)—
HomeH1 ADU—
HomeH1 ADU—
HomeH1 ADU—
—
Dwelling unit – multiple——
Home✓ ADU—
Home✓ ADU—
—
Transitional housing————
Home✓2 ADU—
Permanent supportive housing————
HomeH2 ADU—
Retirement home————
Home✓3 ADU—
Rest home, nursing home, convalescent home————
Home✓3 ADU—
Congregate care facility————
Home✓3 ADU—
Enhanced services facility————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size1,800 sq ft NPMC 18.15.020
No limit NPMC 18.105.050(5)(d)
for Churches, church purposes, use with affordable housing (Chapter 18.105 NPMC) (2, 3, 4+ units)1
Minimum lot widthNo limit NPMC 18.15.010(2)
Minimum lot depthNo limit NPMC 18.15.010(2)
Minimum frontage25 ft NPMC 17.40.020
Maximum density
  • 24 units per acre4 NPMC 18.15.020
  • For every one TDR used, a density bonus is permitted: (A) A 10 percent increase in the unit count (rounded up to the next full unit) for any type of housing developed to meet the city’s housing capacity requirements5 NPMC 18.82.050(2)(a)(i)(A); 18.15.020 note 38
Not set NPMC 18.15.020
for Transitional housing (group living)2; Permanent supportive housing (group living)2; Enhanced services facility (group living)
1 unit per 1,800 ÷ 2 sq ft NPMC 18.15.040(1)(b)(iv); 18.15.020
for Retirement home (group living)3; Rest home, nursing home, convalescent home (group living)3; Congregate care facility (group living)3
Maximum residentsNot set NPMC 18.10.060; 18.15.040(1)(b)
10 persons NPMC 18.44.090(1)
for Transitional housing (group living)2; Permanent supportive housing (group living)2

3. Building standards

StandardValueExceptions
Front setback15 ft NPMC 18.15.020
Maximum front setbackBuildings shall have a primary building facade to either a public right-of-way or private travelway, and at least 75 percent of the building shall be set to a line no farther than two feet from either the public right-of-way or private travelway. NPMC 18.15.036(1)
Side setback10 ft NPMC 18.15.020
Street side setback15 ft NPMC 18.15.020
Rear setback
  • 10 ft6 NPMC 18.15.020
  • 25 ft7 NPMC 18.15.020
Building separation10 ft NPMC 18.15.040(2)(a)
Maximum height
  • 30 ft8 NPMC 18.15.020
  • 35 ft9 NPMC 18.15.020 note 32
Maximum lot coverage50% NPMC 18.15.020; 18.15.020 note 37
Maximum floor area ratio0.5 NPMC 18.15.020
Minimum parking1 + (the largest of bedrooms in one unit − 3, 0) spaces per unit NPMC 18.25.020(2) Chart 18.25.020a
Affordable housing: TBD through development agreement (Chapter 18.105 NPMC) NPMC 18.25.020(2) Chart 18.25.020a; 18.25.020(7)
for Churches, church purposes, use with affordable housing (Chapter 18.105 NPMC) (2, 3, 4+ units)1
0.8 spaces per unit NPMC 18.25.020(2) Chart 18.25.020a
for Retirement home (group living)3
(0.25 × beds in the project) + employees on the largest shift spaces NPMC 18.25.020(2) Chart 18.25.020a
for Rest home, nursing home, convalescent home (group living)3
(0.5 × main dwelling units on the lot) + employees on the largest shift spaces NPMC 18.25.020(2) Chart 18.25.020a
for Congregate care facility (group living)3
Not set NPMC 18.25.020
for Enhanced services facility (group living)
Minimum open spaceNo limit NPMC 18.15.010(2); 18.15.020 note 35

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision NPMC 17.12.010; 18.150.030(4) A up to 4 NPMC 17.12.020(2) —
Minimum lot size
1,800 sq ft NPMC 18.15.020
Minimum lot width
No limit NPMC 18.15.010(2)
Minimum lot depth
No limit NPMC 18.15.010(2)
Minimum frontage
25 ft NPMC 17.12.010(4)
Plat NPMC 17.16.090; 18.150.030(4) H 5 or more NPMC 17.16.010 —
Minimum lot size
1,800 sq ft NPMC 18.15.020
Minimum lot width
No limit NPMC 18.15.010(2)
Minimum lot depth
No limit NPMC 18.15.010(2)
Minimum frontage
25 ft NPMC 17.40.020
Binding site plan NPMC 17.54.020(1); 18.150.030(4) H10
Maximum lots
Not set NPMC 17.54.030
—
Minimum lot size
Not set NPMC 17.54.030
Minimum lot width
Not set NPMC 17.54.030
Minimum lot depth
Not set NPMC 17.54.030
Minimum frontage
25 ft NPMC 17.40.020

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The site is accessed from a major arterial
    • The property is owned by a religious organization
  2. All of these are true:
    • Within one-half-mile walking distance of a bus transit stop
    None of these is true:
    • Within a mile of another property with permanent supportive housing, transitional housing, emergency shelter or emergency housing
  3. Within 800 feet of a public transportation station or terminal
  4. None of these is true:
    • Project uses transfer of development rights under Chapter 18.82 NPMC
  5. Project uses transfer of development rights under Chapter 18.82 NPMC
  6. None of these is true:
    • The yard is adjacent to an R zone
  7. The yard is adjacent to an R zone
  8. None of these is true:
    • The roof is pitched with a minimum slope of three to twelve (3:12)
  9. The roof is pitched with a minimum slope of three to twelve (3:12)
  10. The division creates condominium units