Sign in

DC · Downtown Commercial

North Bend, WA · NBMC 18.12 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-Family Detached Dwellings
Home✓ ADU✓
————
Duplexes—
Home✓ ADU✓
———
Triplex, fourplex, fiveplex, sixplex——
Home✓ ADU✓
——
Other Multifamily Dwellings over Four Units———
Home✓ ADU✓
—
Cottages———
Home✓ ADU—
—
Adult Family Homes————
Home✓ ADU✓

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot read NBMC 18.12.040
24 units NBMC 18.11.040(D)(1)(a)
for Cottages (4+ units)
Minimum unitsNot read NBMC 18.12.040
Not set NBMC 18.11.040(E)(2)(a)
for Cottages (4+ units)
Minimum lot sizeNot read NBMC 18.12.040
0 sq ft NBMC 18.11.040(F)
for Cottages (4+ units)
Minimum lot widthNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Minimum lot depthNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Minimum frontageNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Minimum densityNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Maximum densityNot read NBMC 18.12.040
10 units per acre NBMC 18.11.040(A)(1)
for Cottages (4+ units)
Minimum development sizeNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Maximum residentsNot read NBMC 18.12.040
Maximum bedsNot read NBMC 18.12.040
Maximum sleeping unitsNot read NBMC 18.12.040

3. Building standards

StandardValueExceptions
Front setbackNot read NBMC 18.12.040
20 ft NBMC 18.11.040(H)(1)
for Cottages (4+ units)
Maximum front setbackNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Side setbackNot read NBMC 18.12.040
  • 25 ft1 NBMC 18.11.040(H)(3)
  • 10 ft2 NBMC 18.11.040(H)(2)
for Cottages (4+ units)
Total side setbacksNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Street side setbackNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Rear setbackNot read NBMC 18.12.040
  • 25 ft1 NBMC 18.11.040(H)(3)
  • 10 ft2 NBMC 18.11.040(H)(2)
for Cottages (4+ units)
Building separationNot read NBMC 18.12.040
10 ft NBMC 18.11.040(I)
for Cottages (4+ units)
Maximum heightNot read NBMC 18.12.040
  • 25 ft3 NBMC 18.11.040(K)
  • 18 ft4 NBMC 18.11.040(K)
for Cottages (4+ units)
Maximum storiesNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Minimum heightNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Minimum storiesNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Maximum lot coverageNot read NBMC 18.12.040
50% NBMC 18.11.040(J)
for Cottages (4+ units)
Maximum impervious surfaceNot read NBMC 18.12.040
50% NBMC 18.11.040(J)
for Cottages (4+ units)
Maximum floor area ratioNot read NBMC 18.12.040
0.35 NBMC 18.11.040(A)(3)
for Cottages (4+ units)
Minimum parkingNot read NBMC 18.12.040
  • 1 space per unit5 NBMC 18.11.040(G)(1)
  • 1.5 spaces per unit6 NBMC 18.11.040(G)(2)
  • 2 spaces per unit7 NBMC 18.11.040(G)(3)
for Cottages (4+ units)
Maximum unit sizeNot read NBMC 18.12.040
1,500 sq ft NBMC 18.11.030(A); NBMC 18.11.040(B)(1)
for Cottages (4+ units)
Maximum building floor areaNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Maximum lot sizeNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Maximum building footprintNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Minimum open spaceNot read NBMC 18.12.040
Not set NBMC 18.10.040
for Cottages (4+ units)
Maximum units per buildingNot read NBMC 18.12.040
Not set NBMC 18.11.040
for Cottages (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum unitsNot read NBMC 18.12.040
Minimum lot sizeNot read NBMC 18.12.040

Building

StandardValueExceptions
Front setbackNot read NBMC 18.12.040
Side setbackNot read NBMC 18.12.040
Rear setbackNot read NBMC 18.12.040
Maximum heightNot read NBMC 18.12.040
Maximum storiesNot read NBMC 18.12.040
Minimum parkingNot read NBMC 18.12.040
Maximum unit sizeNot read NBMC 18.12.040
Attached to the main houseNot read NBMC 18.12.040
Owner lives on siteNot read NBMC 18.12.040

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision NBMC 17.12.015; 17.12.060(A) A up to 9 NBMC 17.04.330; 17.12.010 —
Minimum lot size
Not read NBMC 18.12.040
Subdivision NBMC 17.12.015; 17.12.030(A) H 10 or more NBMC 17.04.340 —
Minimum lot size
Not read NBMC 18.12.040

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The setback is from an exterior line abutting property zoned LDR
  2. None of these is true:
    • The setback is from an exterior line abutting property zoned LDR
  3. The home has a roof slope of 6:12 or greater for all parts of the roof higher than 18 feet
  4. None of these is true:
    • The home has a roof slope of 6:12 or greater for all parts of the roof higher than 18 feet
  5. Floor area of one unit is less than 700
  6. All of these are true:
    • Floor area of one unit is at least 700
    • Floor area of one unit is at most 1,000
  7. Floor area of one unit is more than 1,000