Sign in

EP-1 · Employment Park One

North Bend, WA · NBMC 18.10 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Transitional Housing————
Home✓ ADU—
Permanent Supportive Housing————
Home✓ ADU—
Indoor Emergency Shelter————
Home✓ ADU—
Indoor Emergency Housing————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot width50 ft NBMC 18.10.040(3)(e)
Maximum densityNot set NBMC 18.10.040
The density of emergency housing or shelter within a facility shall not exceed the requirements of the underlying zoning designation. No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)
Maximum residentsNot set NBMC 18.10.040
No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)
Maximum bedsNot set NBMC 18.10.040
No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)
Maximum sleeping unitsNot set NBMC 18.10.040
No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)

3. Building standards

StandardValueExceptions
Front setback20 ft NBMC 18.10.040(4)(i)
Side setback25 ft NBMC 18.10.040(6)(f)
Maximum height35 ft NBMC 18.10.040(8)(g)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision NBMC 17.12.015; 17.12.060(A) A up to 9 NBMC 17.04.330; 17.12.010 —
Minimum lot width
50 ft NBMC 18.10.040(3)(e)
Subdivision NBMC 17.12.015; 17.12.030(A) H 10 or more NBMC 17.04.340 —
Minimum lot width
50 ft NBMC 18.10.040(3)(e)
Binding site plan NBMC 17.20.022 A1 — —
Minimum lot width
50 ft NBMC 18.10.040(3)(e)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Any of these is true:
    • The property is commercial or industrial zoned
    • The property is a mobile home park or trailer park
    • The division creates condominium units