Sign in

IMU · Interchange Mixed Use

North Bend, WA · NBMC 18.10 · Official code

By right: 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Duplexes—
Home✓ ADU✓
———
Townhome—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Triplex, fourplex, fiveplex, sixplex——
Home✓ ADU✓
Home✓ ADU✓
—
Other Multifamily Dwellings over Four Units———
Home✓ ADU✓
—
Upper Floor Dwelling Units———
Home✓1 ADU✓1
—
Adult Family Homes————
Home✓ ADU✓2
Homes for the Elderly and Related————
Home✓ ADU✓
Boarding Houses————
Home✓ ADU✓2
Indoor Emergency Shelter————
Home✓ ADU—
Indoor Emergency Housing————
Home✓ ADU—
Interim Housing Facilities————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set NBMC 18.10.040(11)(a)
4 units NBMC 18.06.030
for Triplex, fourplex, fiveplex, sixplex (4+ units)
Minimum unitsNot set NBMC 18.10.030
4 units NBMC 18.06.030
for Triplex, fourplex, fiveplex, sixplex (4+ units)
5 units NBMC 18.10.030 Table 1.24
for Other Multifamily Dwellings over Four Units (4+ units)
Minimum lot size2,000 × main dwelling units on the lot sq ft NBMC 18.10.040(1)(c); NBMC 18.10.040 footnote (4)
Not set NBMC 18.10.040
for Upper Floor Dwelling Units (4+ units)1; Adult Family Homes (group living); Boarding Houses (group living); Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living); Interim Housing Facilities (group living)
10,000 sq ft NBMC 18.10.040(1)(g)
for Homes for the Elderly and Related (group living)
Minimum lot width50 ft NBMC 18.10.040(3)(d)
30 ft NBMC 18.10.040(3)(c)
for Duplexes (2 units)
Not set NBMC 18.10.040
for Upper Floor Dwelling Units (4+ units)1; Adult Family Homes (group living); Homes for the Elderly and Related (group living); Boarding Houses (group living); Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)
Maximum density1 unit per 2,000 sq ft NBMC 18.10.040(1)(c); NBMC 18.10.040 footnote (4)
1 unit per 1,000 sq ft NBMC 18.10.040(1)(h); NBMC 18.10.040 footnote (14)
for Upper Floor Dwelling Units (4+ units)1
Not set NBMC 18.10.040
for Adult Family Homes (group living); Boarding Houses (group living); Interim Housing Facilities (group living)
  • 1 unit per 1,000 sq ft3 NBMC 18.10.040 footnote (5)
  • 1 unit per 700 sq ft4 NBMC 18.10.040 footnote (5)
for Homes for the Elderly and Related (group living)
The density of emergency housing or shelter within a facility shall not exceed the requirements of the underlying zoning designation. No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)
Maximum residentsNot set NBMC 18.10.040
6 persons NBMC 18.10.050(1.31)(b)
for Adult Family Homes (group living)
No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)
100 persons NBMC 18.22.050(B)
for Interim Housing Facilities (group living)
Maximum bedsNot set NBMC 18.10.040
No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)
Maximum sleeping unitsNot set NBMC 18.10.040
2 sleeping units NBMC 18.10.050(1.42)(b)
for Boarding Houses (group living)
No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)

3. Building standards

StandardValueExceptions
Front setback20 ft NBMC 18.10.040(4)(h); NBMC 18.10.040 footnote (14)
10 ft NBMC 18.10.040(4)(c)
for Duplexes (2 units)
Not set NBMC 18.10.040(4)(d)
for Townhome (2, 3, 4+ units); Triplex, fourplex, fiveplex, sixplex (3, 4+ units); Other Multifamily Dwellings over Four Units (4+ units)
Maximum front setback25 ft NBMC 18.10.040(5)(c)
Not set NBMC 18.10.040
for Upper Floor Dwelling Units (4+ units)1; Adult Family Homes (group living); Homes for the Elderly and Related (group living); Boarding Houses (group living); Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living); Interim Housing Facilities (group living)
Side setback10 ft NBMC 18.10.040(6)(d)
5 ft NBMC 18.10.040(6)(c)
for Duplexes (2 units)
Not set NBMC 18.10.040
for Upper Floor Dwelling Units (4+ units)1; Interim Housing Facilities (group living)
Total side setbacksNot set NBMC 18.10.040
15 ft NBMC 18.10.040(6)(c)
for Duplexes (2 units)
Street side setback10 ft NBMC 18.10.040 footnote (9)
Not set NBMC 18.10.040
for Upper Floor Dwelling Units (4+ units)1; Interim Housing Facilities (group living)
Rear setback30 ft NBMC 18.10.040(7)(d)
25 ft NBMC 18.10.040(7)(c)
for Duplexes (2 units)
Not set NBMC 18.10.040
for Upper Floor Dwelling Units (4+ units)1; Interim Housing Facilities (group living)
Building separationNot set NBMC 18.10.040
20 ft NBMC 18.10.040 footnote (10)
for Townhome (2, 3, 4+ units); Triplex, fourplex, fiveplex, sixplex (3, 4+ units); Other Multifamily Dwellings over Four Units (4+ units)
Maximum height35 ft NBMC 18.10.040(8)(d)
Maximum lot coverage60% NBMC 18.10.040(9)(d)
45% NBMC 18.10.040(9)(c)
for Duplexes (2 units)
Not set NBMC 18.10.040
for Upper Floor Dwelling Units (4+ units)1; Interim Housing Facilities (group living)
Maximum impervious surface75% NBMC 18.10.040(10)(b)
65% NBMC 18.10.040(10)(a)
for Duplexes (2 units)
Not set NBMC 18.10.040
for Upper Floor Dwelling Units (4+ units)1; Interim Housing Facilities (group living)
Minimum parking
  • 1 + (1 ÷ 5) spaces per unit5 NBMC 18.16.090
  • 2 spaces per unit6 NBMC 18.16.090
Space to accommodate 1 parking space per employee for the peak employee load, plus 1 space per dwelling unit for units allowing to have on-site storage of vehicles, and 1 space per 10 dwelling units for visitors is required NBMC 18.16.090
for Adult Family Homes (group living); Homes for the Elderly and Related (group living)
1 space per unit NBMC 18.16.090
for Boarding Houses (group living)
Not set NBMC 18.16.090
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living); Interim Housing Facilities (group living)
Maximum units per building10 units NBMC 18.10.040(11)(a)
Not set NBMC 18.10.040
for Duplexes (2 units); Upper Floor Dwelling Units (4+ units)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units NBMC 18.10.050(1.52)(a); NBMC 18.10.041(I)
Minimum lot size0 sq ft NBMC 18.10.050(1.52)(f)(iv)

Building

StandardValueExceptions
Front setbackNot set NBMC 18.10.050(1.52)(f)(i)-(ii); NBMC 18.10.040(4)(d)
10 ft NBMC 18.10.050(1.52)(f)(i)-(ii); NBMC 18.10.040(4)(c)
for Duplexes (2 units)
20 ft NBMC 18.10.050(1.52)(f)(i)-(ii); NBMC 18.10.040(4)(h); NBMC 18.10.040 footnote (14)
for Upper Floor Dwelling Units (4+ units)1; Adult Family Homes (group living)2; Homes for the Elderly and Related (group living); Boarding Houses (group living)2
Side setback
  • 10 ft7 NBMC 18.10.050(1.52)(f)(i); NBMC 18.10.040(6)(d)
  • 10 ft8 NBMC 18.10.050(1.52)(f)(ii); NBMC 18.10.040(6)(d)
  • 5 ft7 NBMC 18.10.050(1.52)(f)(i); NBMC 18.10.040(6)(c)
  • 5 ft8 NBMC 18.10.050(1.52)(f)(ii); NBMC 18.10.040(6)(c)
for Duplexes (2 units)
  • Not set7 NBMC 18.10.050(1.52)(f)(i); NBMC 18.10.040
  • 5 ft8 NBMC 18.10.050(1.52)(f)(ii)
for Upper Floor Dwelling Units (4+ units)1
Rear setback
  • 30 ft7 NBMC 18.10.050(1.52)(f)(i); NBMC 18.10.040(7)(d)
  • 30 ft8 NBMC 18.10.050(1.52)(f)(ii); NBMC 18.10.040(7)(d)
  • 25 ft7 NBMC 18.10.050(1.52)(f)(i); NBMC 18.10.040(7)(c)
  • 25 ft8 NBMC 18.10.050(1.52)(f)(ii); NBMC 18.10.040(7)(c)
for Duplexes (2 units)
  • Not set7 NBMC 18.10.050(1.52)(f)(i); NBMC 18.10.040
  • 10 ft8 NBMC 18.10.050(1.52)(f)(ii)
for Upper Floor Dwelling Units (4+ units)1
Maximum height
  • 35 ft7 NBMC 18.10.050(1.52)(f)(i); NBMC 18.10.040(8)(d)
  • 25 ft8 NBMC 18.10.050(1.52)(f)(iii); NBMC 18.10.040(8)(d)
Minimum parking1 space per unit NBMC 18.16.090; NBMC 18.10.050(1.52)(g)
Maximum unit size1,000 sq ft NBMC 18.10.050(1.52)(c)
Attached to the main houseNot required NBMC 18.10.050(1.52)(b)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision NBMC 17.12.015; 17.12.060(A) A up to 9 NBMC 17.04.330; 17.12.010 —
Minimum lot size
Not set NBMC 18.10.040(1); NBMC 18.10.040 footnote (4)
Subdivision NBMC 17.12.015; 17.12.030(A) H 10 or more NBMC 17.04.340 —
Minimum lot size
Not set NBMC 18.10.040(1); NBMC 18.10.040 footnote (4)
Binding site plan NBMC 17.20.022 A9 — —
Minimum lot size
Not set NBMC 18.10.040(1); NBMC 18.10.040 footnote (4)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The dwelling units are upper floors of a mixed-use building with a ground floor commercial or retail use
  2. The principal dwelling is an existing single-family detached dwelling
  3. The home for the elderly has individually self-sufficient living quarters
  4. None of these is true:
    • The home for the elderly has individually self-sufficient living quarters
  5. Bedrooms in one unit is at most 1
  6. Bedrooms in one unit is at least 2
  7. None of these is true:
    • The ADU is detached from the principal dwelling
  8. The ADU is detached from the principal dwelling
  9. Any of these is true:
    • The property is commercial or industrial zoned
    • The property is a mobile home park or trailer park
    • The division creates condominium units