NB · Neighborhood Business
North Bend, WA · NBMC 18.10 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Adult Family Homes | — | — | — | — | |
| Homes for the Elderly and Related | — | — | — | — | Home✓ ADU— |
| Boarding Houses | — | — | — | — | |
| Indoor Emergency Shelter | — | — | — | — | Home✓ ADU— |
| Indoor Emergency Housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | Not set NBMC 18.10.040 | 10,000 sq ft NBMC 18.10.040(1)(g)
for Homes for the Elderly and Related (group living) |
| Maximum density | Not set NBMC 18.10.040 | for Homes for the Elderly and Related (group living) The density of emergency housing or shelter within a facility shall not exceed the requirements of the underlying zoning designation. No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living) |
| Maximum residents | Not set NBMC 18.10.040 | 6 persons NBMC 18.10.050(1.31)(b)
for Adult Family Homes (group living) No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living) |
| Maximum beds | Not set NBMC 18.10.040 | No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living) |
| Maximum sleeping units | Not set NBMC 18.10.040 | 2 sleeping units NBMC 18.10.050(1.42)(b)
for Boarding Houses (group living) No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | Not set NBMC 18.10.040 | 10 ft NBMC 18.10.040(4)(e)
for Homes for the Elderly and Related (group living) |
| Maximum front setback | Not set NBMC 18.10.040 | 25 ft NBMC 18.10.040(5)(d)
for Homes for the Elderly and Related (group living) |
| Minimum parking | Space to accommodate 1 parking space per employee for the peak employee load, plus 1 space per dwelling unit for units allowing to have on-site storage of vehicles, and 1 space per 10 dwelling units for visitors is required NBMC 18.16.090 | 1 space per unit NBMC 18.16.090
for Boarding Houses (group living) Not set NBMC 18.16.090
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units NBMC 18.10.050(1.52)(a) | |
| Minimum lot size | 0 sq ft NBMC 18.10.050(1.52)(f)(iv) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Minimum parking | 1 space per unit NBMC 18.16.090; NBMC 18.10.050(1.52)(g) | |
| Maximum unit size | 1,000 sq ft NBMC 18.10.050(1.52)(c) | |
| Attached to the main house | Not required NBMC 18.10.050(1.52)(b) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision NBMC 17.12.015; 17.12.060(A) | A | up to 9 NBMC 17.04.330; 17.12.010 | — | Minimum lot width 50 ft NBMC 18.10.040(3)(e) |
| Subdivision NBMC 17.12.015; 17.12.030(A) | H | 10 or more NBMC 17.04.340 | — | Minimum lot width 50 ft NBMC 18.10.040(3)(e) |
| Binding site plan NBMC 17.20.022 | A6 | — | — | Minimum lot width 50 ft NBMC 18.10.040(3)(e) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The principal dwelling is an existing single-family detached dwelling
- The home for the elderly has individually self-sufficient living quarters
- None of these is true:
- The home for the elderly has individually self-sufficient living quarters
- None of these is true:
- The ADU is detached from the principal dwelling
- The ADU is detached from the principal dwelling
- Any of these is true:
- The property is commercial or industrial zoned
- The property is a mobile home park or trailer park
- The division creates condominium units