Sign in

NB · Neighborhood Business

North Bend, WA · NBMC 18.10 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Adult Family Homes————
Home✓ ADU✓1
Homes for the Elderly and Related————
Home✓ ADU—
Boarding Houses————
Home✓ ADU✓1
Indoor Emergency Shelter————
Home✓ ADU—
Indoor Emergency Housing————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNot set NBMC 18.10.040
10,000 sq ft NBMC 18.10.040(1)(g)
for Homes for the Elderly and Related (group living)
Maximum densityNot set NBMC 18.10.040
  • 1 unit per 1,000 sq ft2 NBMC 18.10.040 footnote (5)
  • 1 unit per 700 sq ft3 NBMC 18.10.040 footnote (5)
for Homes for the Elderly and Related (group living)
The density of emergency housing or shelter within a facility shall not exceed the requirements of the underlying zoning designation. No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)
Maximum residentsNot set NBMC 18.10.040
6 persons NBMC 18.10.050(1.31)(b)
for Adult Family Homes (group living)
No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)
Maximum bedsNot set NBMC 18.10.040
No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)
Maximum sleeping unitsNot set NBMC 18.10.040
2 sleeping units NBMC 18.10.050(1.42)(b)
for Boarding Houses (group living)
No occupied structures may exceed occupancy limits set by the currently adopted building code. NBMC 18.10.050(2.42)(a)
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)

3. Building standards

StandardValueExceptions
Front setbackNot set NBMC 18.10.040
10 ft NBMC 18.10.040(4)(e)
for Homes for the Elderly and Related (group living)
Maximum front setbackNot set NBMC 18.10.040
25 ft NBMC 18.10.040(5)(d)
for Homes for the Elderly and Related (group living)
Minimum parkingSpace to accommodate 1 parking space per employee for the peak employee load, plus 1 space per dwelling unit for units allowing to have on-site storage of vehicles, and 1 space per 10 dwelling units for visitors is required NBMC 18.16.090
1 space per unit NBMC 18.16.090
for Boarding Houses (group living)
Not set NBMC 18.16.090
for Indoor Emergency Shelter (group living); Indoor Emergency Housing (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units NBMC 18.10.050(1.52)(a)
Minimum lot size0 sq ft NBMC 18.10.050(1.52)(f)(iv)

Building

StandardValueExceptions
Side setback
  • Not set4 NBMC 18.10.050(1.52)(f)(i); NBMC 18.10.040
  • 5 ft5 NBMC 18.10.050(1.52)(f)(ii)
Rear setback
  • Not set4 NBMC 18.10.050(1.52)(f)(i); NBMC 18.10.040
  • 10 ft5 NBMC 18.10.050(1.52)(f)(ii)
Maximum height
  • Not set4 NBMC 18.10.050(1.52)(f)(i); NBMC 18.10.040
  • 25 ft5 NBMC 18.10.050(1.52)(f)(iii)
Minimum parking1 space per unit NBMC 18.16.090; NBMC 18.10.050(1.52)(g)
Maximum unit size1,000 sq ft NBMC 18.10.050(1.52)(c)
Attached to the main houseNot required NBMC 18.10.050(1.52)(b)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision NBMC 17.12.015; 17.12.060(A) A up to 9 NBMC 17.04.330; 17.12.010 —
Minimum lot width
50 ft NBMC 18.10.040(3)(e)
Subdivision NBMC 17.12.015; 17.12.030(A) H 10 or more NBMC 17.04.340 —
Minimum lot width
50 ft NBMC 18.10.040(3)(e)
Binding site plan NBMC 17.20.022 A6 — —
Minimum lot width
50 ft NBMC 18.10.040(3)(e)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The principal dwelling is an existing single-family detached dwelling
  2. The home for the elderly has individually self-sufficient living quarters
  3. None of these is true:
    • The home for the elderly has individually self-sufficient living quarters
  4. None of these is true:
    • The ADU is detached from the principal dwelling
  5. The ADU is detached from the principal dwelling
  6. Any of these is true:
    • The property is commercial or industrial zoned
    • The property is a mobile home park or trailer park
    • The division creates condominium units