By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family Residences
Home✓ ADU✓
————
Manufactured Homes
Home✓ ADU✓
————
Townhouses
Home✓ ADU✓
————
Transitional Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Permanent Supportive Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Emergency Housing
HomeA1 ADU✓1
————
Duplexes—
Home✓ ADU✓
———
Co-Housing—
HomeA ADU✓
HomeA ADU✓
HomeA ADU✓
—
Apartments———
Home✓2 ADU✓2
—
Courtyard Apartments———
Home✓ ADU✓
—
Group Homes————
Home✓ ADU✓
Boarding Homes————
Home✓ ADU✓
Single Room Occupancy Units————
Home✓ ADU✓
Lodging Houses————
Home✓ ADU✓
Collegiate Greek system residences————
Home✓ ADU✓
Dormitories————
Home✓ ADU✓
Nursing/Convalescent Homes————
HomeH ADU✓
Congregate Care Facilities————
HomeH ADU✓
Retirement Homes————
Home✓ ADU✓
Emergency Housing Facility————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set OMC 18.06.080 Table 6.02 (HDC-2 column)
12 units OMC 18.04.060(II)(3)
for Courtyard Apartments (4+ units)
Minimum unitsNot set OMC 18.06.080 Table 6.02 (HDC-2 column)
4 units OMC 18.04.060(II)(3)
for Courtyard Apartments (4+ units)
Minimum lot size4,000 sq ft OMC 18.06.080 Table 6.02 (HDC-2 column)
1,600 sq ft OMC 18.06.080 Table 6.02 (HDC-2 column)
for Townhouses (1 unit)
Not set OMC 18.04.060(DD)(3)(a)
for Emergency Housing (1 unit)1
6,000 sq ft OMC 18.06.080 Table 6.02 (HDC-2 column)
for Duplexes (2 units)
7,200 sq ft OMC 18.06.080 Table 6.02 (HDC-2 column)
for Apartments (4+ units)2; Courtyard Apartments (4+ units)
7,200 + (500 × (the largest of residents − 9, 0)) sq ft OMC 18.06.060(K)(1); 18.04.060(K)(3)
for Group Homes (group living)3; Group Homes (group living)4
Maximum residentsNot set OMC 18.04.060(K)(2)
  • 8 persons5 OMC 18.06.040 Table 6.01
  • 6 persons6 OMC 18.06.040 Table 6.01
for Group Homes (group living)
40 persons OMC 18.50.060(A)(1)(f)
for Emergency Housing Facility (group living)

3. Building standards

StandardValueExceptions
Front setback0 ft OMC 18.06.080 Table 6.02 (HDC-2 column); 18.130
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Maximum front setback10 ft OMC 18.06.080 Table 6.02 (HDC-2 column); 18.130
Side setback
  • 15 + (5 × (the largest of building stories − 2, 0)) ft7 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • 10 + (5 × (the largest of building stories − 2, 0)) ft8 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • 5 ft9 OMC 18.06.080 Table 6.02 (HDC-2 column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Street side setback10 ft OMC 18.06.080 Table 6.02 (HDC-2 column)
Rear setback
  • 15 + (5 × (the largest of building stories − 2, 0)) ft7 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • 10 + (5 × (the largest of building stories − 2, 0)) ft8 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • 10 ft9 OMC 18.06.080 Table 6.02 (HDC-2 column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Building separationNot set OMC 18.06.080 Table 6.02 (HDC-2 column)
Separation between individual units on the site shall be determined on a site specific visit by the Olympia Building and Fire Departments OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Maximum height
  • 35 ft10 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • The portion of a building within 50' of land zoned for a maximum density of 14 units per acre or more is limited to the lesser of 60' or the height allowed in the abutting district.11 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • 60 + 14 ft12 OMC 18.06.100(A)(6)(b)(ii)
  • 60 ft13 OMC 18.06.080 Table 6.02 (HDC-2 column)
Maximum lot coverage70% OMC 18.06.080 Table 6.02 (HDC-2 column)
Maximum impervious surface85% OMC 18.06.080 Table 6.02 (HDC-2 column)
Minimum parking
  • 0 spaces per unit14 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • ((0.5 + 1.5) ÷ 2) × 0.9 spaces per unit15 OMC 18.38.100 Table 38.01; 18.38.160(A)
  • 0 spaces per unit14 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.5 spaces per unit15 OMC 18.38.100 Table 38.01
for Single-family Residences (1 unit); Manufactured Homes (1 unit); Townhouses (1 unit); Duplexes (2 units)
Not set OMC 18.38.100 Table 38.01
for Emergency Housing (1 unit)1
  • 0 spaces per unit14 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • employees on the largest shift + (residents ÷ 5) spaces15 OMC 18.38.100 Table 38.01
for Group Homes (group living); Group Homes (group living)3; Group Homes (group living)4
  • 0 spaces per sleeping unit14 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.25 spaces per sleeping unit15 OMC 18.38.100(C)(5)
for Boarding Homes (group living); Single Room Occupancy Units (group living); Lodging Houses (group living)
  • 0 spaces per unit14 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 3) + 1 spaces15 OMC 18.38.100 Table 38.01
for Collegiate Greek system residences (group living); Dormitories (group living)
  • 0 spaces per unit14 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 2) + (employees on the largest shift ÷ 2) spaces15 OMC 18.38.100 Table 38.01
for Nursing/Convalescent Homes (group living); Congregate Care Facilities (group living); Retirement Homes (group living)
Adequate on-site parking shall be provided for the Emergency Housing Facility, as determined by the City upon review of the application. OMC 18.50.060(A)(1)(g)
for Emergency Housing Facility (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units OMC 18.04.060(A)(1); 18.04.060(A)(6)

Building

StandardValueExceptions
Front setback0 ft OMC 18.06.080 Table 6.02 (HDC-2 column); 18.130
Side setback
  • 15 + (5 × (the largest of building stories − 2, 0)) ft7 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • 10 + (5 × (the largest of building stories − 2, 0)) ft8 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • 5 ft9 OMC 18.06.080 Table 6.02 (HDC-2 column)
Rear setback
  • 15 + (5 × (the largest of building stories − 2, 0)) ft7 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • 10 + (5 × (the largest of building stories − 2, 0)) ft8 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • 10 ft9 OMC 18.06.080 Table 6.02 (HDC-2 column)
Maximum height
  • 35 ft10 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • The portion of a building within 50' of land zoned for a maximum density of 14 units per acre or more is limited to the lesser of 60' or the height allowed in the abutting district.11 OMC 18.06.080 Table 6.02 (HDC-2 column)
  • 60 + 14 ft12 OMC 18.06.100(A)(6)(b)(ii)
  • 60 ft13 OMC 18.06.080 Table 6.02 (HDC-2 column)
Minimum parking0 spaces per unit OMC 18.38.100 Table 38.01
Maximum unit size1,000 sq ft OMC 18.04.060(A)(3)
Attached to the main houseNot required OMC 18.04.060(A)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision OMC 17.32.130(A); 18.70.040 A up to 9 OMC 17.12.010(EE); 17.32.010 —
Minimum lot size
No limit OMC 18.06.080 Table 6.02 (HDC-2 column)
Subdivision OMC 17.16.080; 18.70.040 H 10 or more OMC 17.12.010(HH) —
Minimum lot size
No limit OMC 18.06.080 Table 6.02 (HDC-2 column)
Unit Lot Subdivisions OMC 17.33.010(B)(1) — — — —
Binding Site Plans OMC 17.34.010; 17.34.070(A) A — —
Minimum lot size
No limit OMC 17.34.020
Large lot subdivision OMC 17.36.100(A) A 2 or more OMC 17.36.010 —
Minimum lot size
217,800 sq ft OMC 17.36.010

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. A dwelling on the lot is being reconstructed after damage from earthquake, fire, storm or other natural disaster
  2. Main dwelling units on the lot is more than 4
  3. All of these are true:
    • Any of these is true:
      • Residents is more than 8
      • All of these are true:
        • Residents is more than 6
        • None of these is true:
          • DSHS approves the group home for up to 8 clients
    • Residents is at most 20
  4. Residents is more than 20
  5. DSHS approves the group home for up to 8 clients
  6. None of these is true:
    • DSHS approves the group home for up to 8 clients
  7. The yard is next to an R 4, R 4-8 or R 6-12 district
  8. All of these are true:
    • The yard is next to an MR 7-13, MR 10-18, RM-18, RM-24 or RMH district
    None of these is true:
    • The yard is next to an R 4, R 4-8 or R 6-12 district
  9. None of these is true:
    • The yard is next to an R 4, R 4-8 or R 6-12 district
    • The yard is next to an MR 7-13, MR 10-18, RM-18, RM-24 or RMH district
  10. The portion of the building is within 100 feet of land zoned for a maximum density of less than 14 units per acre
  11. All of these are true:
    • The portion of the building is within 50 feet of land zoned for a maximum density of 14 units per acre or more
    None of these is true:
    • The portion of the building is within 100 feet of land zoned for a maximum density of less than 14 units per acre
  12. All of these are true:
    • The project builds one additional story for residential development
    None of these is true:
    • The portion of the building is within 100 feet of land zoned for a maximum density of less than 14 units per acre
    • The portion of the building is within 50 feet of land zoned for a maximum density of 14 units per acre or more
    • Site is within 100 feet of a designated historic district
  13. All of these are true:
    • Not all of these are true:
      • The project builds one additional story for residential development
      • None of these is true:
        • Site is within 100 feet of a designated historic district
    None of these is true:
    • The portion of the building is within 100 feet of land zoned for a maximum density of less than 14 units per acre
    • The portion of the building is within 50 feet of land zoned for a maximum density of 14 units per acre or more
  14. Any of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)
  15. None of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)