HDC-2 · High Density Corridor-2
Olympia, WA · OMC 18.06 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family Residences | Home✓ ADU✓ | — | — | — | — |
| Manufactured Homes | Home✓ ADU✓ | — | — | — | — |
| Townhouses | Home✓ ADU✓ | — | — | — | — |
| Transitional Housing | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Permanent Supportive Housing | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Emergency Housing | — | — | — | — | |
| Duplexes | — | Home✓ ADU✓ | — | — | — |
| Co-Housing | — | HomeA ADU✓ | HomeA ADU✓ | HomeA ADU✓ | — |
| Apartments | — | — | — | — | |
| Courtyard Apartments | — | — | — | Home✓ ADU✓ | — |
| Group Homes | — | — | — | — | Home✓ ADU✓ |
| Boarding Homes | — | — | — | — | Home✓ ADU✓ |
| Single Room Occupancy Units | — | — | — | — | Home✓ ADU✓ |
| Lodging Houses | — | — | — | — | Home✓ ADU✓ |
| Collegiate Greek system residences | — | — | — | — | Home✓ ADU✓ |
| Dormitories | — | — | — | — | Home✓ ADU✓ |
| Nursing/Convalescent Homes | — | — | — | — | HomeH ADU✓ |
| Congregate Care Facilities | — | — | — | — | HomeH ADU✓ |
| Retirement Homes | — | — | — | — | Home✓ ADU✓ |
| Emergency Housing Facility | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set OMC 18.06.080 Table 6.02 (HDC-2 column) | 12 units OMC 18.04.060(II)(3)
for Courtyard Apartments (4+ units) |
| Minimum units | Not set OMC 18.06.080 Table 6.02 (HDC-2 column) | 4 units OMC 18.04.060(II)(3)
for Courtyard Apartments (4+ units) |
| Minimum lot size | 4,000 sq ft OMC 18.06.080 Table 6.02 (HDC-2 column) | 1,600 sq ft OMC 18.06.080 Table 6.02 (HDC-2 column)
for Townhouses (1 unit) Not set OMC 18.04.060(DD)(3)(a)
for Emergency Housing (1 unit)1 6,000 sq ft OMC 18.06.080 Table 6.02 (HDC-2 column)
for Duplexes (2 units) 7,200 sq ft OMC 18.06.080 Table 6.02 (HDC-2 column)
|
| Maximum residents | Not set OMC 18.04.060(K)(2) | for Group Homes (group living) 40 persons OMC 18.50.060(A)(1)(f)
for Emergency Housing Facility (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft OMC 18.06.080 Table 6.02 (HDC-2 column); 18.130 | 6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living) |
| Maximum front setback | 10 ft OMC 18.06.080 Table 6.02 (HDC-2 column); 18.130 | |
| Side setback | 6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living) | |
| Street side setback | 10 ft OMC 18.06.080 Table 6.02 (HDC-2 column) | |
| Rear setback | 6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living) | |
| Building separation | Not set OMC 18.06.080 Table 6.02 (HDC-2 column) | Separation between individual units on the site shall be determined on a site specific visit by the Olympia Building and Fire Departments OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living) |
| Maximum height |
|
|
| Maximum lot coverage | 70% OMC 18.06.080 Table 6.02 (HDC-2 column) | |
| Maximum impervious surface | 85% OMC 18.06.080 Table 6.02 (HDC-2 column) | |
| Minimum parking | for Single-family Residences (1 unit); Manufactured Homes (1 unit); Townhouses (1 unit); Duplexes (2 units) Not set OMC 18.38.100 Table 38.01
for Emergency Housing (1 unit)1 for Boarding Homes (group living); Single Room Occupancy Units (group living); Lodging Houses (group living) for Collegiate Greek system residences (group living); Dormitories (group living) for Nursing/Convalescent Homes (group living); Congregate Care Facilities (group living); Retirement Homes (group living) Adequate on-site parking shall be provided for the Emergency Housing Facility, as determined by the City upon review of the application. OMC 18.50.060(A)(1)(g)
for Emergency Housing Facility (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units OMC 18.04.060(A)(1); 18.04.060(A)(6) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft OMC 18.06.080 Table 6.02 (HDC-2 column); 18.130 | |
| Side setback | ||
| Rear setback | ||
| Maximum height |
|
|
| Minimum parking | 0 spaces per unit OMC 18.38.100 Table 38.01 | |
| Maximum unit size | 1,000 sq ft OMC 18.04.060(A)(3) | |
| Attached to the main house | Not required OMC 18.04.060(A)(2) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision OMC 17.32.130(A); 18.70.040 | A | up to 9 OMC 17.12.010(EE); 17.32.010 | — | Minimum lot size No limit OMC 18.06.080 Table 6.02 (HDC-2 column) |
| Subdivision OMC 17.16.080; 18.70.040 | H | 10 or more OMC 17.12.010(HH) | — | Minimum lot size No limit OMC 18.06.080 Table 6.02 (HDC-2 column) |
| Unit Lot Subdivisions OMC 17.33.010(B)(1) | — | — | — | — |
| Binding Site Plans OMC 17.34.010; 17.34.070(A) | A | — | — | Minimum lot size No limit OMC 17.34.020 |
| Large lot subdivision OMC 17.36.100(A) | A | 2 or more OMC 17.36.010 | — | Minimum lot size 217,800 sq ft OMC 17.36.010 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- A dwelling on the lot is being reconstructed after damage from earthquake, fire, storm or other natural disaster
- Main dwelling units on the lot is more than 4
- All of these are true:
- Any of these is true:
- Residents is more than 8
- All of these are true:
- Residents is more than 6
- None of these is true:
- DSHS approves the group home for up to 8 clients
- Residents is at most 20
- Any of these is true:
- Residents is more than 20
- DSHS approves the group home for up to 8 clients
- None of these is true:
- DSHS approves the group home for up to 8 clients
- The yard is next to an R 4, R 4-8 or R 6-12 district
- All of these are true:
- The yard is next to an MR 7-13, MR 10-18, RM-18, RM-24 or RMH district
- The yard is next to an R 4, R 4-8 or R 6-12 district
- None of these is true:
- The yard is next to an R 4, R 4-8 or R 6-12 district
- The yard is next to an MR 7-13, MR 10-18, RM-18, RM-24 or RMH district
- The portion of the building is within 100 feet of land zoned for a maximum density of less than 14 units per acre
- All of these are true:
- The portion of the building is within 50 feet of land zoned for a maximum density of 14 units per acre or more
- The portion of the building is within 100 feet of land zoned for a maximum density of less than 14 units per acre
- All of these are true:
- The project builds one additional story for residential development
- The portion of the building is within 100 feet of land zoned for a maximum density of less than 14 units per acre
- The portion of the building is within 50 feet of land zoned for a maximum density of 14 units per acre or more
- Site is within 100 feet of a designated historic district
- All of these are true:
- Not all of these are true:
- The project builds one additional story for residential development
- None of these is true:
- Site is within 100 feet of a designated historic district
- The portion of the building is within 100 feet of land zoned for a maximum density of less than 14 units per acre
- The portion of the building is within 50 feet of land zoned for a maximum density of 14 units per acre or more
- Not all of these are true:
- Any of these is true:
- Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
- Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
- Site is in the Downtown Exempt Parking Area (Figure 38-2)
- None of these is true:
- Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
- Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
- Site is in the Downtown Exempt Parking Area (Figure 38-2)