Sign in

RMU · Residential Mixed Use

Olympia, WA · OMC 18.04 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family Residences
Home✓ ADU✓
————
Manufactured Homes
Home✓ ADU✓
————
Townhouses
Home✓ ADU✓
————
Transitional Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Permanent Supportive Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Duplexes—
Home✓ ADU✓
———
Co-Housing—
HomeA ADU✓
HomeA ADU✓
HomeA ADU✓
—
Triplexes——
Home✓ ADU✓
——
Apartments——
Home✓ ADU✓
Home✓ ADU✓
—
Fourplexes———
Home✓ ADU✓
—
Cottage Housing———
Home✓ ADU✓
—
Group Homes————
Home✓ ADU✓
Lodging Houses————
Home✓ ADU✓
Dormitories————
Home✓ ADU✓
Nursing/Convalescent Homes————
HomeH ADU✓
Retirement Homes————
HomeH ADU✓
Hospice Care————
HomeH ADU✓
Emergency Housing Facility————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set OMC 18.04.080 Table 4.04 (RMU column)
4 units OMC 18.04.040 Table 4.01
for Fourplexes (4+ units)
12 units OMC 18.04.060(H)(3)
for Cottage Housing (4+ units)
Minimum unitsNot set OMC 18.04.080 Table 4.04 (RMU column)
4 units OMC 18.04.060(H)(3)
for Cottage Housing (4+ units)
Minimum lot size
  • No limit1 OMC 18.04.080(C)(2)
  • Not set2 OMC 18.04.080 Table 4.04 (RMU column)
  • No limit1 OMC 18.04.080(C)(2)
  • 1,600 sq ft2 OMC 18.04.080 Table 4.04 (RMU column)
for Townhouses (1 unit)
Not set OMC 18.04.080 Table 4.04 (RMU column)
for Group Homes (group living); Lodging Houses (group living); Dormitories (group living); Nursing/Convalescent Homes (group living); Retirement Homes (group living); Hospice Care (group living); Emergency Housing Facility (group living)
7,200 + (500 × (the largest of residents − 9, 0)) sq ft OMC 18.04.060(K)(3)
for Group Homes (group living)3; Group Homes (group living)4
Minimum lot widthNo limit OMC 18.04.080 Table 4.04 (RMU column)
Maximum densityNo limit OMC 18.04.080 Table 4.04 (RMU column)
Not set OMC 18.04.080 Table 4.04 (RMU column)
for Group Homes (group living); Group Homes (group living)3; Group Homes (group living)4; Lodging Houses (group living); Dormitories (group living); Nursing/Convalescent Homes (group living); Retirement Homes (group living); Hospice Care (group living); Emergency Housing Facility (group living)
Maximum residentsNot set OMC 18.04.060(K)(2)
  • 8 persons5 OMC 18.04.040 Table 4.01
  • 6 persons6 OMC 18.04.040 Table 4.01
for Group Homes (group living)
40 persons OMC 18.50.060(A)(1)(f)
for Emergency Housing Facility (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 20 ft7 OMC 18.04.080 Table 4.04 (RMU column)
  • 10 ft8 OMC 18.04.080 Table 4.04 (RMU column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Side setbackNo limit OMC 18.04.080 Table 4.04 (RMU column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Rear setback5 ft OMC 18.04.080 Table 4.04 (RMU column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Building separationNot set OMC 18.04.080 Table 4.04 (RMU column)
Separation between individual units on the site shall be determined on a site specific visit by the Olympia Building and Fire Departments OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Maximum heightNot read OMC 18.04.080(I)(2)(a)
Maximum lot coverageNot set OMC 18.04.080 Table 4.04 (RMU column)
60% OMC 18.64.080(C)
for Townhouses (1 unit)
Maximum impervious surface85% OMC 18.04.080 Table 4.04 (RMU column)
Minimum parking
  • 0 spaces per unit9 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.5 spaces per unit10 OMC 18.38.100 Table 38.01
  • 0 spaces per unit9 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • employees on the largest shift + (residents ÷ 5) spaces10 OMC 18.38.100 Table 38.01
for Group Homes (group living); Group Homes (group living)3; Group Homes (group living)4
  • 0 spaces per sleeping unit9 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.25 spaces per sleeping unit10 OMC 18.38.100(C)(5)
for Lodging Houses (group living)
  • 0 spaces per unit9 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 3) + 1 spaces10 OMC 18.38.100 Table 38.01
for Dormitories (group living)
  • 0 spaces per unit9 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 2) + (employees on the largest shift ÷ 2) spaces10 OMC 18.38.100 Table 38.01
for Nursing/Convalescent Homes (group living); Retirement Homes (group living); Hospice Care (group living)
Adequate on-site parking shall be provided for the Emergency Housing Facility, as determined by the City upon review of the application. OMC 18.50.060(A)(1)(g)
for Emergency Housing Facility (group living)
Maximum unit sizeNot set OMC 18.04.080 Table 4.04 (RMU column)
1,600 sq ft OMC 18.04.060(H)(4)
for Cottage Housing (4+ units)
Maximum building footprintNot set OMC 18.04.080 Table 4.04 (RMU column)
1,000 sq ft OMC 18.04.060(H)(4)
for Cottage Housing (4+ units)
Minimum open space
  • 10%11 OMC 18.04.080 Table 4.04 (RMU column)
  • Not set12 OMC 18.04.080 Table 4.04 (RMU column)
20% OMC 18.04.060(H)(1); 18.04.080(J)(2); 18.04.080(J)(2)(a)
for Cottage Housing (4+ units)
Not set OMC 18.04.080 Table 4.04 (RMU column)
for Group Homes (group living); Group Homes (group living)3; Group Homes (group living)4; Lodging Houses (group living); Dormitories (group living); Nursing/Convalescent Homes (group living); Retirement Homes (group living); Hospice Care (group living); Emergency Housing Facility (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units OMC 18.04.060(A)(1); 18.04.060(A)(6)

Building

StandardValueExceptions
Front setback
  • 20 ft7 OMC 18.04.080 Table 4.04 (RMU column)
  • 10 ft8 OMC 18.04.080 Table 4.04 (RMU column)
Side setbackNo limit OMC 18.04.080 Table 4.04 (RMU column); 18.04.080(H)(5)(b)
Rear setback
  • 0 ft13 OMC 18.04.080(H)(5)(b)
  • 5 ft14 OMC 18.04.080(H)(5)(b)
Maximum height
  • 24 ft15 OMC 18.04.080 Table 4.04 (RMU column)
  • Not read16 OMC 18.04.080(I)(2)(a)
Minimum parking0 spaces per unit OMC 18.38.100 Table 38.01
Maximum unit size1,000 sq ft OMC 18.04.060(A)(3)
Attached to the main houseNot required OMC 18.04.060(A)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision OMC 17.32.130(A); 18.70.040 A up to 9 OMC 17.12.010(EE); 17.32.010 —
Minimum lot size
Not set OMC 18.04.080 Table 4.04 (RMU column)
Minimum lot width
No limit OMC 18.04.080 Table 4.04 (RMU column)
Subdivision OMC 17.16.080; 18.70.040 H 10 or more OMC 17.12.010(HH) —
Minimum lot size
Not set OMC 18.04.080 Table 4.04 (RMU column)
Minimum lot width
No limit OMC 18.04.080 Table 4.04 (RMU column)
Unit Lot Subdivisions OMC 17.33.010(E); 17.32.130(A) A up to 9 OMC 17.33.010(E) —
Minimum lot size
Not set OMC 17.33.010(C)(1)
Unit Lot Subdivisions OMC 17.33.010(E); 17.16.080 H 10 or more OMC 17.33.010(E); 17.12.010(HH) —
Minimum lot size
Not set OMC 17.33.010(C)(1)
Large lot subdivision OMC 17.36.100(A) A 2 or more OMC 17.36.010 —
Minimum lot size
217,800 sq ft OMC 17.36.010

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Any of these is true:
    • The undersized lot was recorded before June 19, 1995
    • The undersized lot was approved as part of a Planned Residential Development, Master Planned Development or clustered housing development
  2. None of these is true:
    • The undersized lot was recorded before June 19, 1995
    • The undersized lot was approved as part of a Planned Residential Development, Master Planned Development or clustered housing development
  3. All of these are true:
    • Any of these is true:
      • Residents is more than 8
      • All of these are true:
        • Residents is more than 6
        • None of these is true:
          • DSHS approves the group home for up to 8 clients
    • Residents is at most 20
  4. Residents is more than 20
  5. DSHS approves the group home for up to 8 clients
  6. None of these is true:
    • DSHS approves the group home for up to 8 clients
  7. Front lot line is along Legion Way
  8. None of these is true:
    • Front lot line is along Legion Way
  9. Any of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)
  10. None of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)
  11. All of these are true:
    • Main dwelling units on the lot is at least 7
    • The project is subject to land use review
  12. Not all of these are true:
    • Main dwelling units on the lot is at least 7
    • The project is subject to land use review
  13. The lot abuts an alley
  14. None of these is true:
    • The lot abuts an alley
  15. The ADU is detached from the principal unit
  16. None of these is true:
    • The ADU is detached from the principal unit