Sign in

UW-H · Urban Waterfront - Housing

Olympia, WA · OMC 18.06 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Townhouses
Home✓ ADU✓
————
Transitional Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Permanent Supportive Housing
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Co-Housing—
HomeA ADU✓
HomeA ADU✓
HomeA ADU✓
—
Apartments———
Home✓1 ADU✓1
—
Group Homes————
Home✓ ADU✓
Boarding Homes————
Home✓ ADU✓
Single Room Occupancy Units————
Home✓ ADU✓
Collegiate Greek system residences————
Home✓ ADU✓
Dormitories————
Home✓ ADU✓
Retirement Homes————
Home✓ ADU✓
Emergency Housing Facility————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit OMC 18.06.080 Table 6.02 (UW-H column)
7,200 + (500 × (the largest of residents − 9, 0)) sq ft OMC 18.06.060(K)(1); 18.04.060(K)(3)
for Group Homes (group living)2; Group Homes (group living)3
Maximum residentsNot set OMC 18.04.060(K)(2)
  • 8 persons4 OMC 18.06.040 Table 6.01
  • 6 persons5 OMC 18.06.040 Table 6.01
for Group Homes (group living)
40 persons OMC 18.50.060(A)(1)(f)
for Emergency Housing Facility (group living)

3. Building standards

StandardValueExceptions
Front setbackNo limit OMC 18.06.080 Table 6.02 (UW-H column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Side setbackNo limit OMC 18.06.080 Table 6.02 (UW-H column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Rear setbackNo limit OMC 18.06.080 Table 6.02 (UW-H column)
6 ft OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Building separationNot set OMC 18.06.080 Table 6.02 (UW-H column)
Separation between individual units on the site shall be determined on a site specific visit by the Olympia Building and Fire Departments OMC 18.50.060(D)(1)(f)
for Emergency Housing Facility (group living)
Maximum heightNot read OMC 18.06.100(A)(5)(a)
Maximum lot coverage100% OMC 18.06.080 Table 6.02 (UW-H column)
Maximum impervious surface100% OMC 18.06.080 Table 6.02 (UW-H column); 18.64.080(C)
Minimum parking
  • 0 spaces per unit6 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.5 spaces per unit7 OMC 18.38.100 Table 38.01
  • 0 spaces per unit6 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • employees on the largest shift + (residents ÷ 5) spaces7 OMC 18.38.100 Table 38.01
for Group Homes (group living); Group Homes (group living)2; Group Homes (group living)3
  • 0 spaces per sleeping unit6 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • 0.25 spaces per sleeping unit7 OMC 18.38.100(C)(5)
for Boarding Homes (group living); Single Room Occupancy Units (group living)
  • 0 spaces per unit6 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 3) + 1 spaces7 OMC 18.38.100 Table 38.01
for Collegiate Greek system residences (group living); Dormitories (group living)
  • 0 spaces per unit6 OMC 18.38.100 Table 38.01; 18.38.100(C)(4); 18.38.160(C)(2)
  • (beds in the project ÷ 2) + (employees on the largest shift ÷ 2) spaces7 OMC 18.38.100 Table 38.01
for Retirement Homes (group living)
Adequate on-site parking shall be provided for the Emergency Housing Facility, as determined by the City upon review of the application. OMC 18.50.060(A)(1)(g)
for Emergency Housing Facility (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units OMC 18.04.060(A)(1); 18.04.060(A)(6)

Building

StandardValueExceptions
Front setbackNo limit OMC 18.06.080 Table 6.02 (UW-H column)
Side setbackNo limit OMC 18.06.080 Table 6.02 (UW-H column)
Rear setbackNo limit OMC 18.06.080 Table 6.02 (UW-H column)
Maximum heightNot read OMC 18.06.100(A)(5)(a)
Minimum parking0 spaces per unit OMC 18.38.100 Table 38.01
Maximum unit size1,000 sq ft OMC 18.04.060(A)(3)
Attached to the main houseNot required OMC 18.04.060(A)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision OMC 17.32.130(A); 18.70.040 A up to 9 OMC 17.12.010(EE); 17.32.010 —
Minimum lot size
No limit OMC 18.06.080 Table 6.02 (UW-H column)
Subdivision OMC 17.16.080; 18.70.040 H 10 or more OMC 17.12.010(HH) —
Minimum lot size
No limit OMC 18.06.080 Table 6.02 (UW-H column)
Unit Lot Subdivisions OMC 17.33.010(B)(1) — — — —
Binding Site Plans OMC 17.34.010; 17.34.070(A) A — —
Minimum lot size
No limit OMC 17.34.020
Large lot subdivision OMC 17.36.100(A) A 2 or more OMC 17.36.010 —
Minimum lot size
217,800 sq ft OMC 17.36.010

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Main dwelling units on the lot is more than 4
  2. All of these are true:
    • Any of these is true:
      • Residents is more than 8
      • All of these are true:
        • Residents is more than 6
        • None of these is true:
          • DSHS approves the group home for up to 8 clients
    • Residents is at most 20
  3. Residents is more than 20
  4. DSHS approves the group home for up to 8 clients
  5. None of these is true:
    • DSHS approves the group home for up to 8 clients
  6. Any of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)
  7. None of these is true:
    • Lot is within one-half mile of a frequent transit route (transit service 4 or more times per hour for 12 or more hours per day, as defined in OMC 18.02.180)
    • Site is in the Capital Mall Triangle, the area bounded by Cooper Point Road, Black Lake Boulevard, and Harrison Avenue
    • Site is in the Downtown Exempt Parking Area (Figure 38-2)