Res - Conservation · Residential-Conservation Zone
Orting, WA · OMC 13-3-2(A) · Official code
By right: 1 unit · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family detached | — | — | — | — | |
| Manufactured home | — | — | — | — | |
| Cottage | — | — | — | — | |
| Manufactured home park | — | — | — | HomeH ADU— | — |
| Adult family homes | — | — | — | — | |
| Permanent supportive housing | — | — | — | — | HomeH ADU— |
| Transitional housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 87,120 sq ft OMC 13-5-1(C) Table 1 | Not set OMC 13-5-1(C) Table 1
for Manufactured home park (4+ units) |
| Minimum lot width | No limit OMC 13-5-1(C) Table 1 | |
| Minimum lot depth | No limit OMC 13-5-1(C) Table 1 | |
| Maximum density | 0.5 units per acre OMC 13-5-1(C) Table 1; OMC 13-5-1(C) Table 1 (note 2) | Not set OMC 13-5-1(C) Table 1
for Adult family homes (group living) |
| Maximum residents | 2 × bedrooms in the whole project persons OMC 13-3-3(B) Table 1 (note 22) | 6 persons OMC 13-2-2
for Adult family homes (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft OMC 13-5-1(C) Table 1 | |
| Side setback | 8 ft OMC 13-5-1(C) Table 1 | |
| Street side setback | 25 ft OMC 13-5-1(C)(2); OMC 13-5-1(C) Table 1 | |
| Rear setback | 25 ft OMC 13-5-1(C) Table 1 | |
| Maximum height | 35 ft OMC 13-5-1(C) Table 1 | |
| Maximum lot coverage | 20% OMC 13-5-1(C) Table 1 | |
| Maximum impervious surface | 50% OMC 13-5-1(C) Table 1 | |
| Minimum parking | 2 spaces per unit OMC 13-5-3(I)(3) | 0.5 spaces per bed OMC 13-5-3(I)(3)
for Adult family homes (group living) |
| Maximum unit size | Not set OMC 13-5-1 | 1,000 sq ft OMC 13-6-5(D)(9)
for Cottage (1 unit) |
| Maximum building footprint | Not set OMC 13-5-1 | 650 sq ft OMC 13-6-5(D)(9)
for Cottage (1 unit) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units OMC 13-5-6(C)(1) | |
| Minimum lot size | 87,120 sq ft OMC 13-5-6(C)(2); OMC 13-5-1(C) Table 1 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft OMC 13-5-6(C)(6)(c); OMC 13-5-1(C) Table 1 | |
| Side setback | 8 ft OMC 13-5-6(C)(6)(c); OMC 13-5-1(C) Table 1 | |
| Rear setback | 25 ft OMC 13-5-6(C)(6)(c); OMC 13-5-1(C) Table 1 | |
| Maximum height | 24 ft OMC 13-5-6(C)(6)(d) | |
| Minimum parking |
|
|
| Maximum unit size | 1,200 sq ft OMC 13-5-6(C)(4) | |
| Attached to the main house | Not required OMC 13-5-6(C)(3)(a) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, short OMC 12-4-2 | A | up to 9 OMC 12-2-2 | — | Minimum lot size 87,120 sq ft OMC 13-5-1(C) Table 1 Minimum lot width No limit OMC 13-5-1(C) Table 1 Minimum lot depth No limit OMC 13-5-1(C) Table 1 |
| Subdivision OMC 12-5-2 | A | 10 or more OMC 12-2-2 | — | Minimum lot size 87,120 sq ft OMC 13-5-1(C) Table 1 Minimum lot width No limit OMC 13-5-1(C) Table 1 Minimum lot depth No limit OMC 13-5-1(C) Table 1 |
| Binding site plan OMC 12-10-4Only for: Manufactured home park | A | — | Not set OMC 12-10 | Minimum lot size Not set OMC 12-10 |
| Lot size averaging OMC 13-5-1(I)(2)Only for: Single-family detached | A | — | 0.5 units per acre OMC 13-5-1(I)(1); OMC 13-5-1(C) Table 1 Minimum average lot size 87,120 sq ft OMC 13-5-1(I)(3)(b); OMC 13-5-1(C) Table 1 |
Minimum lot size 87,120 × 0.75 sq ft OMC 13-5-1(I)(3)(e) Minimum lot width 40 ft OMC 13-5-1(I)(3)(f) Minimum lot depth 70 ft OMC 13-5-1(I)(3)(g) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The lot is designated with critical areas or their buffers under Title 11 OMC or the Shoreline Master Program
- All of these are true:
- The manufactured home is on a permanent foundation
- The manufactured home is no older than three years old on the date it is placed on the lot
- All of these are true:
- The manufactured home is on a permanent foundation
- The manufactured home is no older than three years old on the date it is placed on the lot
- The lot is designated with critical areas or their buffers under Title 11 OMC or the Shoreline Master Program
- None of these is true:
- The parcel abuts or is directly across a public right-of-way from a parcel with an existing school or park use
- The parcel is in the main street area bounded by Whitsell Street, Bridge Street, Corrin Avenue Northwest, and Rainier Lane Northeast
- The ADU is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is less than 6,000 sf
- The ADU is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is at least 6,000 sf
- The ADU is within one-half mile walking distance of a major transit stop