Res - Multi-family · Residential-Multi-Family Zone
Orting, WA · OMC 13-3-2(C) · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family detached | — | — | — | — | |
| Manufactured home | — | — | — | — | |
| Cottage | — | — | — | — | |
| Duplex | — | Home✓ ADU— | — | — | — |
| Cottage housing development | — | — | |||
| Townhouse | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Multi-family | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Manufactured home park | — | — | — | HomeH ADU— | — |
| Adult family homes | — | — | — | — | |
| Group residences | — | — | — | — | HomeH ADU— |
| Other | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | HomeH ADU— |
| Transitional housing | — | — | — | — | |
| Rooming house | — | — | — | — | HomeH ADU— |
| Single room occupancy sleeping units | — | — | — | — | |
| Fraternity, sorority, or group student houses | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | Not set OMC 13-5-1(C) Table 1 | 5,450 sq ft OMC 13-5-1(C) Table 1 (note 5)
7,000 sq ft OMC 13-5-1(C) Table 1 (note 6)
for Duplex (2 units); Townhouse (2, 3, 4+ units) 2,250 × main dwelling units on the lot sq ft OMC 13-6-5(D)(1)
for Cottage housing development (2, 3, 4+ units) 4,000 + (2,000 × (main dwelling units on the lot − 1)) sq ft OMC 13-5-1(C) Table 1 (note 7)
for Multi-family (2, 3, 4+ units) |
| Minimum lot width | 40 ft OMC 13-5-1(C) Table 1 | |
| Minimum lot depth | 100 ft OMC 13-5-1(C) Table 1 | |
| Minimum frontage | Not set OMC 13-5-1 | 20 ft OMC 13-6-5(D)(11)
for Cottage housing development (2, 3, 4+ units) |
| Maximum density | 8 units per acre OMC 13-5-1(C) Table 1; OMC 13-5-1(C) Table 1 (note 2) | Not set OMC 13-5-1(C) Table 1
for Adult family homes (group living); Group residences (group living); Other (group living); Rooming house (group living); Single room occupancy sleeping units (group living)5; Fraternity, sorority, or group student houses (group living) |
| Maximum residents | Not set OMC 13-3-3 | 6 persons OMC 13-2-2
for Adult family homes (group living) 2 × bedrooms in the whole project persons OMC 13-3-3(B) Table 1 (note 22)
|
| Maximum sleeping units | Not set OMC 13-3-3 | 4 × ((8 × lot area) ÷ 43,560, rounded down) sleeping units OMC 13-5-1(C) Table 1; OMC 13-3-3(B) Table 1 (note 26)
for Single room occupancy sleeping units (group living)5 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft OMC 13-5-1(C) Table 1 | |
| Side setback | 8 ft OMC 13-5-1(C) Table 1 | |
| Street side setback | 25 ft OMC 13-5-1(C)(2); OMC 13-5-1(C) Table 1 | |
| Rear setback | 25 ft OMC 13-5-1(C) Table 1 | |
| Building separation | Not set OMC 13-5-1 | 10 ft OMC 13-6-5(D)(5)
for Cottage housing development (2, 3, 4+ units) |
| Maximum height | 35 ft OMC 13-5-1(C) Table 1 | 18 ft OMC 13-6-5(D)(6)
for Cottage housing development (2, 3, 4+ units) |
| Maximum lot coverage | 50% OMC 13-5-1(C) Table 1 | 40% OMC 13-6-5(D)(7)
for Cottage housing development (2, 3, 4+ units) |
| Maximum impervious surface | 75% OMC 13-5-1(C) Table 1 | 60% OMC 13-6-5(D)(8)
for Cottage housing development (2, 3, 4+ units) |
| Minimum parking | 2 spaces per unit OMC 13-5-3(I)(3) | 0.5 spaces per bed OMC 13-5-3(I)(3)
for Adult family homes (group living) In the case of a use not specifically mentioned in subsection I of this section, the requirements for off street parking facilities shall be determined by the Administrator. OMC 13-5-3(H)
for Group residences (group living); Other (group living) 1 space per sleeping unit OMC 13-5-3(I)(3)
for Rooming house (group living) 0.25 spaces per sleeping unit OMC 13-5-3(I)(3)(note 4)
for Single room occupancy sleeping units (group living)5 the largest of sleeping units in the project ÷ 3, beds in the project ÷ 6 spaces OMC 13-5-3(I)(3)
for Fraternity, sorority, or group student houses (group living) |
| Maximum unit size | Not set OMC 13-5-1 | 1,000 sq ft OMC 13-6-5(D)(9)
for Cottage (1 unit); Cottage housing development (2, 3, 4+ units) |
| Maximum building footprint | Not set OMC 13-5-1 | 650 sq ft OMC 13-6-5(D)(9)
for Cottage (1 unit); Cottage housing development (2, 3, 4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units OMC 13-5-6(C)(1) | |
| Minimum lot size | 5,450 sq ft OMC 13-5-6(C)(2); OMC 13-5-1(C) Table 1 (note 5) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft OMC 13-5-6(C)(6)(c); OMC 13-5-1(C) Table 1 | |
| Side setback | 8 ft OMC 13-5-6(C)(6)(c); OMC 13-5-1(C) Table 1 | |
| Rear setback | 25 ft OMC 13-5-6(C)(6)(c); OMC 13-5-1(C) Table 1 | |
| Maximum height | 24 ft OMC 13-5-6(C)(6)(d) | |
| Minimum parking |
|
|
| Maximum unit size | 1,200 sq ft OMC 13-5-6(C)(4) | |
| Attached to the main house | Not required OMC 13-5-6(C)(3)(a) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, short OMC 12-4-2 | A | up to 9 OMC 12-2-2 | — | Minimum lot size 5,450 sq ft OMC 13-5-1(C) Table 1 (note 5) Minimum lot width 40 ft OMC 13-5-1(C) Table 1 Minimum lot depth 100 ft OMC 13-5-1(C) Table 1 |
| Subdivision OMC 12-5-2 | A | 10 or more OMC 12-2-2 | — | Minimum lot size 5,450 sq ft OMC 13-5-1(C) Table 1 (note 5) Minimum lot width 40 ft OMC 13-5-1(C) Table 1 Minimum lot depth 100 ft OMC 13-5-1(C) Table 1 |
| Unit lot short subdivision OMC 12-4-4(E)Only for: Duplex, Cottage housing development, Townhouse, Multi-family | A | up to 9 OMC 12-4-4(A) | — | Minimum lot size No limit OMC 12-4-4(C)(2) Minimum lot width No limit OMC 12-4-4(C)(2) Minimum lot depth No limit OMC 12-4-4(C)(2) |
| Unit lot subdivision OMC 12-5-3.5(E)Only for: Duplex, Cottage housing development, Townhouse, Multi-family | A | 10 or more OMC 12-5-3.5(A) | — | Minimum lot size No limit OMC 12-5-3.5(C)(2) Minimum lot width No limit OMC 12-5-3.5(C)(2) Minimum lot depth No limit OMC 12-5-3.5(C)(2) |
| Binding site plan OMC 12-10-4Only for: Multi-family, Manufactured home park, Cottage housing development | A | — | Not set OMC 12-10 | Minimum lot size Not set OMC 12-10 |
| Lot size averaging OMC 13-5-1(I)(2)Only for: Single-family detached, Duplex, Townhouse | A | — | 8 units per acre OMC 13-5-1(I)(1); OMC 13-5-1(C) Table 1 Minimum average lot size 5,450 sq ft OMC 13-5-1(I)(3)(b); OMC 13-5-1(C) Table 1 (note 5) |
Minimum lot size 5,450 × 0.75 sq ft OMC 13-5-1(I)(3)(e) Minimum lot width 40 ft OMC 13-5-1(I)(3)(f) Minimum lot depth 70 ft OMC 13-5-1(I)(3)(g) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The lot is designated with critical areas or their buffers under Title 11 OMC or the Shoreline Master Program
- All of these are true:
- The manufactured home is on a permanent foundation
- The manufactured home is no older than three years old on the date it is placed on the lot
- All of these are true:
- The manufactured home is on a permanent foundation
- The manufactured home is no older than three years old on the date it is placed on the lot
- The lot is designated with critical areas or their buffers under Title 11 OMC or the Shoreline Master Program
- None of these is true:
- The parcel abuts or is directly across a public right-of-way from a parcel with an existing school or park use
- The parcel is in the main street area bounded by Whitsell Street, Bridge Street, Corrin Avenue Northwest, and Rainier Lane Northeast
- Lot area is at least 32,670 sf
- The ADU is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is less than 6,000 sf
- The ADU is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is at least 6,000 sf
- The ADU is within one-half mile walking distance of a major transit stop