High Density Residential District · Multiple-family residential
Pacific, WA · PMC 20.48 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwellings | Home✓ ADU— | — | — | — | — |
| Permanent supportive housing | HomeH ADU— | HomeH ADU— | HomeH ADU— | HomeH ADU— | — |
| Transitional housing | HomeH ADU— | HomeH ADU— | HomeH ADU— | HomeH ADU— | — |
| Duplexes | — | Home✓ ADU— | — | — | — |
| Multiple-family dwellings | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Adult family homes | — | — | — | — | Home✓ ADU— |
| Boardinghouses and roominghouses | — | — | — | — | Home✓ ADU— |
| Group care homes | — | — | — | — | Home✓ ADU— |
| Homes for the aged | — | — | — | — | Home✓ ADU— |
| Nursing homes | — | — | — | — | Home✓ ADU— |
| Indoor emergency housing | — | — | — | — | |
| Indoor emergency shelter | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 10 units PMC 20.68.200(B)(3)(a) | Not set PMC 20.48
for Multiple-family dwellings (4+ units) |
| Minimum lot size | the largest of 8,000, (4,000 × (the smallest of main dwelling units on the lot, 2)) + (2,200 × (the largest of main dwelling units on the lot − 2, 0)) sq ft PMC 20.48.050(A)-(B) | |
| Minimum lot width | 70 ft PMC 20.48.050(C) | |
| Maximum residents | Not set PMC 20.68.200 | 6 persons PMC 20.04.037
for Adult family homes (group living) 4 persons PMC 20.04.095
for Boardinghouses and roominghouses (group living) 10 persons PMC 20.06.020(D)
for Group care homes (group living) |
| Maximum beds | Not set PMC 20.68.200 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 30 ft PMC 20.48.050(D) | |
| Side setback | 10 ft PMC 20.48.050(F)(1) | |
| Street side setback | 15 ft PMC 20.48.070; 20.48.050(D) | |
| Rear setback | 30 ft PMC 20.48.050(E) | |
| Building separation | Not set PMC 20.48.050 | 20 ft PMC 20.48.050(F)(2)
for Multiple-family dwellings (3, 4+ units) |
| Maximum height | 35 ft PMC 20.48.040 | |
| Maximum stories | 2.5 stories PMC 20.48.040 | |
| Maximum lot coverage | 45% PMC 20.48.060 | |
| Minimum parking | The minimum number of off-street parking spaces required for each facility will be determined by the decision maker through the approval process, taking into consideration factors such as the potential number of residents, site constraints, and impact on the surrounding neighborhood. PMC 20.68.200(B)(1)(g) | 2 spaces per unit PMC 20.72.130
for Single-family dwellings (1 unit) for Multiple-family dwellings (3, 4+ units) The parking space requirements for buildings and uses not set forth herein shall be determined by the director and such determination shall be based upon the requirements for the most comparable building or use specified herein. PMC 20.72.140
for Adult family homes (group living) 1 space per sleeping unit PMC 20.72.130
for Boardinghouses and roominghouses (group living) beds in the project ÷ 5 spaces PMC 20.72.130
for Group care homes (group living); Homes for the aged (group living); Nursing homes (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short plat PMC 19.12.010 | A | up to 4 PMC 19.04.010(27) | — | Minimum lot size the largest of 8,000, (4,000 × (the smallest of main dwelling units on the lot, 2)) + (2,200 × (the largest of main dwelling units on the lot − 2, 0)) sq ft PMC 20.48.050(A)-(B) Minimum lot width 70 ft PMC 20.48.050(C) |
| Subdivision PMC 19.08.040(C); 19.08.010 | H | 5 or more PMC 19.04.010(29); 19.08.030 | — | Minimum lot size the largest of 8,000, (4,000 × (the smallest of main dwelling units on the lot, 2)) + (2,200 × (the largest of main dwelling units on the lot − 2, 0)) sq ft PMC 20.48.050(A)-(B) Minimum lot width 70 ft PMC 20.48.050(C) |
| Planned unit developments PMC 20.69.020; 20.69.290 | H | — | The development shall be allowed an increase in density of not to exceed 10 percent over the regulations of the parent zone in which the development is located, except as more restrictive regulations may be prescribed as a condition of approval of a planned unit development permit pursuant to PMC § 20.69.300. PMC 20.69.140 | Minimum lot size the minimum lot area, width, and frontage, height and yard requirements otherwise applying in the district shall not dictate the strict guidelines for development of the planned unit development but shall serve to inform the designers of the importance of developing a project that will be in harmony with the character of the surrounding neighborhood. PMC 20.69.230 Minimum lot width the minimum lot area, width, and frontage, height and yard requirements otherwise applying in the district shall not dictate the strict guidelines for development of the planned unit development but shall serve to inform the designers of the importance of developing a project that will be in harmony with the character of the surrounding neighborhood. PMC 20.69.230 Minimum frontage the minimum lot area, width, and frontage, height and yard requirements otherwise applying in the district shall not dictate the strict guidelines for development of the planned unit development but shall serve to inform the designers of the importance of developing a project that will be in harmony with the character of the surrounding neighborhood. PMC 20.69.230 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- Facility would be closer than 1,000 feet to an elementary, middle, or high school
- Lot area is less than 6,000 sf
- Lot area is more than 6,000 sf
- All of these are true:
- Lot area is more than 6,000 sf
- Lot is within one-quarter mile of a transit stop that receives transit service at least two times per hour for 12 or more hours a day
- All of these are true:
- Lot area is more than 6,000 sf
- Lot is within one-quarter mile of a transit stop that receives transit service at least two times per hour for 12 or more hours a day