EC · Employment Center
Pierce County, WA · PCC 18A.10.080(A)(2)(a) · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached Single-Family Housing | — | — | — | — | |
| Group Home | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size |
|
Not set PCC Table 18A.15.020-1
for Group Home (group living)3 |
| Maximum density |
|
Not set PCC 18A.15.020
for Group Home (group living)3 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Maximum front setback | Not read PCC Title 18J | |
| Side setback | ||
| Street side setback | ||
| Rear setback | ||
| Maximum height | ||
| Minimum parking | 2 spaces per unit PCC Table 18A.35.040-1 | |
| Maximum unit size | Not set PCC 18A.33.210
for Group Home (group living)3 | |
| Minimum open space | Not read PCC Title 18J |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units PCC 18A.37.120(A)(1) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | ||
| Rear setback | ||
| Maximum height | If an ADU is created by constructing a new detached structure, the building height of the ADU shall not be greater than the principal dwelling's building height PCC 18A.37.120(A)(5) | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft PCC 18A.37.120(B) | |
| Attached to the main house | Not required PCC 18A.37.120(A)(2) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision PCC 18F.40.020 | ✓ | — | Not set PCC 18A.15.020 | Minimum lot size Not set PCC Table 18A.15.020-1 |
| Short subdivision PCC 18F.50.040(E) | A | — | Not set PCC 18A.15.020 | Minimum lot size Not set PCC Table 18A.15.020-1 |
| Unit Lot Subdivision PCC 18F.40.100Only for: Detached Single-Family Housing | ✓ | — | Not set PCC 18A.15.020 | Minimum lot size Not set PCC 18F.40.100(D)(1) |
| Unit Lot Subdivision PCC 18F.50.040(E); 18F.50.070Only for: Detached Single-Family Housing | A | — | Not set PCC 18A.15.020 | Minimum lot size Not set PCC 18F.50.070(D)(1) |
| Infill Lot Creation PCC 18A.15.050(B)(1) | ✓ | — | Not set PCC 18A.15.020 | Minimum lot size Not set PCC 18A.15.050(B)(5) Maximum lot size Not set PCC 18A.15.050(B)(9) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The community plan area the lot is in (outside means not in an adopted community plan area) is frederickson
- The vacant lot of record existed prior to January 1, 1995
- The parcel was created for residential use
- Lot area is at most 87,120 sf
- All of these are true:
- The community plan area the lot is in (outside means not in an adopted community plan area) is frederickson
- The vacant lot of record existed prior to January 1, 1995
- The parcel was created for residential use
- Lot area is at most 87,120 sf
- Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
- All of these are true:
- The community plan area the lot is in (outside means not in an adopted community plan area) is frederickson
- The housing will be occupied by persons who qualify as handicapped under the Federal Fair Housing Act
- The lot was legally created
- None of these is true:
- The lot was legally created
- The lot is a pipestem lot, or its only access is a shared access facility
- All of these are true:
- A principal building has been established on an adjacent lot within the required front yard
- The lot is a pipestem lot, or its only access is a shared access facility
- The adjacent lot has received a reduced setback based upon a discretionary land use approval
- All of these are true:
- Not all of these are true:
- A principal building has been established on an adjacent lot within the required front yard
- None of these is true:
- The adjacent lot has received a reduced setback based upon a discretionary land use approval
- The front yard abuts an arterial
- The lot is a pipestem lot, or its only access is a shared access facility
- Not all of these are true:
- All of these are true:
- Not all of these are true:
- A principal building has been established on an adjacent lot within the required front yard
- None of these is true:
- The adjacent lot has received a reduced setback based upon a discretionary land use approval
- The lot is a pipestem lot, or its only access is a shared access facility
- The front yard abuts an arterial
- Not all of these are true:
- None of these is true:
- The lot is a pipestem lot, or its only access is a shared access facility
- All of these are true:
- The front yard abuts an arterial
- The lot is a pipestem lot, or its only access is a shared access facility
- None of these is true:
- The lot is a pipestem lot, or its only access is a shared access facility
- The front yard abuts an arterial
- The building is within 150 feet of property not zoned EC or ECOR
- None of these is true:
- The building is within 150 feet of property not zoned EC or ECOR
- Within one-half mile of a major transit stop (RCW 36.70A.681)
- None of these is true:
- Within one-half mile of a major transit stop (RCW 36.70A.681)
- The dwelling is built on a residential infill lot created through an Infill Lot Subdivision
- None of these is true:
- The dwelling is built on a residential infill lot created through an Infill Lot Subdivision
- All of these are true:
- The ADU is detached from the principal structure
- The separation between the principal structure and the ADU is less than 100 linear feet
- The lot is a pipestem lot, or its only access is a shared access facility
- The ADU is created by converting an existing (pre-existing) detached structure
- The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
- All of these are true:
- Not all of these are true:
- The ADU is detached from the principal structure
- The separation between the principal structure and the ADU is less than 100 linear feet
- None of these is true:
- The ADU is created by converting an existing (pre-existing) detached structure
- None of these is true:
- The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
- The front yard abuts an arterial
- The lot is a pipestem lot, or its only access is a shared access facility
- Not all of these are true:
- All of these are true:
- Not all of these are true:
- The ADU is detached from the principal structure
- The separation between the principal structure and the ADU is less than 100 linear feet
- None of these is true:
- The ADU is created by converting an existing (pre-existing) detached structure
- None of these is true:
- The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
- The lot is a pipestem lot, or its only access is a shared access facility
- The front yard abuts an arterial
- Not all of these are true:
- All of these are true:
- The ADU is created by converting an existing (pre-existing) detached structure
- The lot is a pipestem lot, or its only access is a shared access facility
- None of these is true:
- The lot is a pipestem lot, or its only access is a shared access facility
- The ADU is created by converting an existing (pre-existing) detached structure