Sign in

SR · Suburban Residential

Pierce County, WA · PCC 18A.10.080(D)(2)(c) · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Mobile Home
Home✓ ADU—
————
Detached Single-Family Housing
Home✓ ADU✓1
————
Duplexes—
Home✓ ADU✓1
———
Attached Single-Family Housing—
Home✓ ADU✓1
Home✓ ADU✓1
Home✓ ADU✓1
—
Middle Housing——
Home✓ ADU✓1
Home✓ ADU✓1
—
Mobile Home Park———
Home✓ ADU—
—
Senior Housing Level 2———
HomeA ADU—
—
Cottage Housing———
Home✓2 ADU—
—
Group Home————
Home✓3 H4 ADU—
Residential Care Facility Level 1————
Home✓ ADU—
Residential Care Facility Level 2————
HomeH ADU—
Senior Housing Level 1————
HomeA ADU—
Boarding and Rooming Houses————
Home✓ ADU—
Shared Housing Villages————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set PCC 18A.33.210
5 units PCC 18A.33.210(G)
for Middle Housing (4+ units)
16 units PCC 18A.33.210(G)
for Cottage Housing (4+ units)2
Minimum lot size
  • No limit5 PCC 18A.15.030(B)(2)(a)
  • the largest of 5,000, 5,000 − 2,000 sq ft6 PCC 18A.15.030(B)(2)(b); 18A.15.030(B)(2)(b)(1); 18A.15.030(B)(2)(b)(2); 18A.15.030(B)(2)(b)(3); Table 18A.15.020-1
  • 5,000 sq ft7 PCC Table 18A.15.020-1
  • No limit5 PCC 18A.15.030(B)(2)(a)
  • In any zone that permits a single-family dwelling unit, a single-family dwelling unit and permitted accessory structures may be constructed or enlarged on a lot which cannot satisfy the lot size and/or density requirements of the zone where the lot was legally created.8 PCC 18A.15.010(B)
  • the largest of 5,000, 5,000 − 2,000 sq ft9 PCC 18A.15.030(B)(2)(b); 18A.15.030(B)(2)(b)(1); 18A.15.030(B)(2)(b)(2); 18A.15.030(B)(2)(b)(3); Table 18A.15.020-1
  • 5,000 sq ft10 PCC Table 18A.15.020-1
for Detached Single-Family Housing (1 unit)
Minimum lot width50 ft PCC Table 18A.15.020-1
Minimum density
  • 0 units per acre, on the net lot area11 PCC 18A.15.020(B)(2)(a)
  • 4 × 0.5 units per acre, on the net lot area12 PCC Table 18A.15.020-1; 18A.15.020(A)(9)
  • 4 units per acre, on the net lot area13 PCC Table 18A.15.020-1
Not set PCC 18A.15.020
for Group Home (group living)4; Group Home (group living)3; Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living); Senior Housing Level 1 (group living); Boarding and Rooming Houses (group living); Shared Housing Villages (group living)
Maximum density
  • the smallest of 1.33 × 6, 6 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.33 × 6, 6 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 4 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 4 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 6 units per acre, a fraction of 0.5 or more rounds up, on the net lot area20 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 6 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area21 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area22 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area23 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • the smallest of 1.33 × 6, 6 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area24 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.33 × 6, 6 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area25 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • In any zone that permits a single-family dwelling unit, a single-family dwelling unit and permitted accessory structures may be constructed or enlarged on a lot which cannot satisfy the lot size and/or density requirements of the zone where the lot was legally created.26 PCC 18A.15.010(B)
  • 4 units per acre, a fraction of 0.5 or more rounds up, on the net lot area27 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 4 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area28 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area29 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area30 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 6 units per acre, a fraction of 0.5 or more rounds up, on the net lot area31 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 6 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area32 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area33 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area34 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
for Detached Single-Family Housing (1 unit)
  • the smallest of 1.33 × 8, 8 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.15.020(E)(1)(d); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.33 × 8, 8 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.15.020(E)(1)(d); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 4 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 4 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 8 units per acre, a fraction of 0.5 or more rounds up, on the net lot area20 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.15.020(E)(1)(d)
  • 8 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area21 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.15.020(E)(1)(d); PCC 18A.15.020(E)(1)(e)
  • 8 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area22 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.15.020(E)(1)(d); PCC 18A.15.020(E)(1)(e)
  • 8 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area23 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.15.020(E)(1)(d); PCC 18A.15.020(E)(1)(e)
for Senior Housing Level 2 (4+ units); Senior Housing Level 1 (group living)
4 × 2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area PCC Table 18A.15.020-1; PCC 18A.15.020(E)(1)(i)
for Cottage Housing (4+ units)2
Not set PCC 18A.15.020
for Group Home (group living)4; Group Home (group living)3; Boarding and Rooming Houses (group living); Shared Housing Villages (group living)
Maximum sleeping unitsNot set PCC 18A.33.210
  • 4 × ((4 × lot area minus critical areas and buffers) ÷ 43,560, rounded) sleeping units35 PCC Table 18A.15.020-1; PCC 18A.15.020(A)(8)
  • 4 × ((6 × lot area minus critical areas and buffers) ÷ 43,560, rounded) sleeping units36 PCC Table 18A.15.020-1; PCC 18A.15.020(A)(8); PCC 18A.15.020(D)
for Boarding and Rooming Houses (group living); Shared Housing Villages (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 5 ft37 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Averaging may be used to reduce a front setback requirement when a principal building has been established on an adjacent lot within the required yard. Averaging shall be calculated by adding the existing front setbacks of the adjacent lots together and dividing that figure by two. In the case of a corner lot or when an adjacent lot is vacant, averaging shall be calculated by adding the front setback of the adjacent developed lot with the minimum front setback of the zone in which the construction is proposed and dividing that figure by two.38 PCC 18A.15.040(B)(3)(b); 18A.15.040(B)(3)(b)(1); 18A.15.040(B)(3)(b)(2)
  • 25 ft39 PCC Table 18A.15.040-1
  • 15 ft40 PCC Table 18A.15.040-1
Maximum front setbackNot read PCC Title 18J
Side setback
  • 5 ft37 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • the smallest of 5, the largest of 3, 0.1 × lot width ft41 PCC Table 18A.15.040-1; PCC 18A.15.040(B)(4)(c)
  • the smallest of 5, the largest of 3, 0.15 × lot width ft42 PCC Table 18A.15.040-1; PCC 18A.15.040(B)(4)(c)
  • the smallest of 5, the largest of 3, 0.25 × lot width ft43 PCC Table 18A.15.040-1; PCC 18A.15.040(B)(4)(c)
  • 5 ft44 PCC Table 18A.15.040-1
  • 5 ft37 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 0 ft45 PCC Table 18A.15.040-1 note (2)
  • the smallest of 5, the largest of 3, 0.1 × lot width ft46 PCC Table 18A.15.040-1; PCC 18A.15.040(B)(4)(c)
  • the smallest of 5, the largest of 3, 0.15 × lot width ft47 PCC Table 18A.15.040-1; PCC 18A.15.040(B)(4)(c)
  • the smallest of 5, the largest of 3, 0.25 × lot width ft48 PCC Table 18A.15.040-1; PCC 18A.15.040(B)(4)(c)
  • 5 ft49 PCC Table 18A.15.040-1
for Duplexes (2 units); Attached Single-Family Housing (2, 3, 4+ units); Middle Housing (3, 4+ units); Senior Housing Level 2 (4+ units)
Street side setback
  • 5 ft37 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 25 ft50 PCC 18A.15.040(A)(2); PCC Table 18A.15.040-1
  • 15 ft51 PCC 18A.15.040(A)(2)
Rear setback
  • 5 ft37 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 5 ft52 PCC 18A.15.040(B)(2)(k)(1)(b)
  • 10 ft53 PCC Table 18A.15.040-1
Maximum height35 ft PCC Table 18A.15.040-3
Minimum parking2 spaces per unit PCC Table 18A.35.040-1
In the case of a land use not specifically mentioned in Table 18A.35.040-1, required off-street parking shall be determined by the approval authority. PCC 18A.35.040(E)
for Mobile Home Park (4+ units)
  • 0 spaces per unit54 PCC Table 18A.35.040-1 note (3)
  • 0.5 × bedrooms in the whole project spaces55 PCC Table 18A.35.040-1
for Senior Housing Level 2 (4+ units); Group Home (group living)4; Group Home (group living)3; Senior Housing Level 1 (group living)
  • 1 space per unit56 PCC Table 18A.35.040-1
  • 1.5 spaces per unit57 PCC Table 18A.35.040-1
  • 1.5 spaces per unit58 PCC Table 18A.35.040-1
for Cottage Housing (4+ units)2
(beds in the project ÷ 4) + (employees on the largest shift ÷ 2) spaces PCC Table 18A.35.040-1
for Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living)
  • 0 spaces per sleeping unit54 PCC Table 18A.35.040-1 note (3)
  • 0.25 spaces per sleeping unit55 PCC Table 18A.35.040-1
for Boarding and Rooming Houses (group living); Shared Housing Villages (group living)
Maximum unit size
  • 1,400 sq ft59 PCC 18A.15.050(B)(16)
  • Not set60 PCC 18A.33.210
  • 1,400 sq ft59 PCC 18A.15.050(B)(16)
  • Not read60 PCC Title 18J
for Cottage Housing (4+ units)2
Not set PCC 18A.33.210
for Group Home (group living)4; Group Home (group living)3; Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living); Senior Housing Level 1 (group living); Boarding and Rooming Houses (group living); Shared Housing Villages (group living)
Minimum open spaceNot read PCC Title 18J
Maximum units per buildingNot set PCC 18A.33.210
2 units PCC 18A.33.210(G)
for Duplexes (2 units)
5 units PCC 18A.33.210(G)
for Middle Housing (3, 4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units PCC 18A.37.120(A)(1)

Building

StandardValueExceptions
Front setback
  • 5 ft37 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Detached ADUs shall be no closer to the front lot line than the closest point to the front lot line of the principal structure, unless the ADU was created by the conversion of a pre-existing structure into the ADU.61 PCC 18A.37.120(C)(1)
  • 25 ft62 PCC 18A.37.120(A)(4); Table 18A.15.040-1; 18A.37.120(C)(2)(c)
  • 15 ft63 PCC 18A.37.120(A)(4); Table 18A.15.040-1; 18A.37.120(C)(2)(c)
Side setback
  • 5 ft37 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Conversion of an existing detached structure to an ADU shall be permitted within the side or rear yard setback when the structure is located within the UGA.64 PCC 18A.37.120(A)(6)
  • 5 ft65 PCC Table 18A.15.040-1
Rear setback
  • 5 ft37 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Conversion of an existing detached structure to an ADU shall be permitted within the side or rear yard setback when the structure is located within the UGA.64 PCC 18A.37.120(A)(6)
  • 2 ft66 PCC 18A.37.120(C)(2)(b)
  • 5 ft67 PCC 18A.37.120(C)(2)(a)
Maximum height35 ft PCC 18A.37.120(A)(5); Table 18A.15.040-3
Minimum parking
  • 0 spaces per unit54 PCC 18A.37.120(E)(1)(a); Table 18A.35.040-1 note (3)
  • 1 space per unit55 PCC Table 18A.35.040-1; 18A.37.120(E)(1)(b)
Maximum unit size1,000 sq ft PCC 18A.37.120(B)
Attached to the main houseNot required PCC 18A.37.120(A)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision PCC 18F.40.020 ✓ —
  • the smallest of 1.33 × 6, 6 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.33 × 6, 6 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 4 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 4 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 6 units per acre, a fraction of 0.5 or more rounds up, on the net lot area20 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 6 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area21 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area22 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area23 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Minimum density
  • 0 units per acre, on the net lot area11 PCC 18A.15.020(B)(2)(a)
  • 4 × 0.5 units per acre, on the net lot area12 PCC Table 18A.15.020-1; 18A.15.020(A)(9)
  • 4 units per acre, on the net lot area13 PCC Table 18A.15.020-1
Minimum average lot size
  • No limit5 PCC 18A.15.030(B)(2)(a)
  • 6,000 − 2,000 sq ft6 PCC 18A.15.030(B)(2)(b); 18A.15.030(B)(2)(b)(1); 18A.15.030(B)(2)(b)(2); 18A.15.030(B)(2)(b)(3); Table 18A.15.020-1
  • 6,000 sq ft7 PCC Table 18A.15.020-1
Minimum lot size
  • No limit5 PCC 18A.15.030(B)(2)(a)
  • the largest of 5,000, 5,000 − 2,000 sq ft6 PCC 18A.15.030(B)(2)(b); 18A.15.030(B)(2)(b)(1); 18A.15.030(B)(2)(b)(2); 18A.15.030(B)(2)(b)(3); Table 18A.15.020-1
  • 5,000 sq ft7 PCC Table 18A.15.020-1
Minimum lot width
50 ft PCC Table 18A.15.020-1
Short subdivision PCC 18F.50.040(E) A —
  • the smallest of 1.33 × 6, 6 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.33 × 6, 6 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 4 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 4 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 6 units per acre, a fraction of 0.5 or more rounds up, on the net lot area20 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 6 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area21 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area22 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area23 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Minimum density
  • 0 units per acre, on the net lot area11 PCC 18A.15.020(B)(2)(a)
  • 4 × 0.5 units per acre, on the net lot area12 PCC Table 18A.15.020-1; 18A.15.020(A)(9)
  • 4 units per acre, on the net lot area13 PCC Table 18A.15.020-1
Minimum average lot size
  • No limit5 PCC 18A.15.030(B)(2)(a)
  • 6,000 − 2,000 sq ft6 PCC 18A.15.030(B)(2)(b); 18A.15.030(B)(2)(b)(1); 18A.15.030(B)(2)(b)(2); 18A.15.030(B)(2)(b)(3); Table 18A.15.020-1
  • 6,000 sq ft7 PCC Table 18A.15.020-1
Minimum lot size
  • No limit5 PCC 18A.15.030(B)(2)(a)
  • the largest of 5,000, 5,000 − 2,000 sq ft6 PCC 18A.15.030(B)(2)(b); 18A.15.030(B)(2)(b)(1); 18A.15.030(B)(2)(b)(2); 18A.15.030(B)(2)(b)(3); Table 18A.15.020-1
  • 5,000 sq ft7 PCC Table 18A.15.020-1
Minimum lot width
50 ft PCC Table 18A.15.020-1
Unit Lot Subdivision PCC 18F.40.100Only for: Detached Single-Family Housing, Duplexes, Attached Single-Family Housing, Cottage Housing ✓ —
  • the smallest of 1.33 × 6, 6 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.33 × 6, 6 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 4 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 4 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 6 units per acre, a fraction of 0.5 or more rounds up, on the net lot area20 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 6 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area21 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area22 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area23 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Minimum lot size
Not set PCC 18F.40.100(D)(1)
Unit Lot Subdivision PCC 18F.50.040(E); 18F.50.070Only for: Detached Single-Family Housing, Duplexes, Attached Single-Family Housing, Cottage Housing A —
  • the smallest of 1.33 × 6, 6 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.33 × 6, 6 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 4 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 4 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 6 units per acre, a fraction of 0.5 or more rounds up, on the net lot area20 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 6 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area21 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area22 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area23 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Minimum lot size
Not set PCC 18F.50.070(D)(1)
Infill Lot Creation PCC 18A.15.050(B)(1) ✓68 —
  • the smallest of 1.33 × 6, 6 + ((1.5 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area14 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • the smallest of 1.33 × 6, 6 + ((1 × units that are income-restricted affordable housing × 43,560) ÷ lot area minus critical areas and buffers) units per acre, a fraction of 0.5 or more rounds up, on the net lot area15 PCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A.
  • 4 units per acre, a fraction of 0.5 or more rounds up, on the net lot area16 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4)
  • 4 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area17 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area18 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 4 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area19 PCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4); PCC 18A.15.020(E)(1)(e)
  • 6 units per acre, a fraction of 0.5 or more rounds up, on the net lot area20 PCC Table 18A.15.020-1; PCC 18A.15.020(D)
  • 6 × 1.15 units per acre, a fraction of 0.5 or more rounds up, on the net lot area21 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.2 units per acre, a fraction of 0.5 or more rounds up, on the net lot area22 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
  • 6 × 1.25 units per acre, a fraction of 0.5 or more rounds up, on the net lot area23 PCC Table 18A.15.020-1; PCC 18A.15.020(D); PCC 18A.15.020(E)(1)(e)
Maximum parent area
87,120 sq ft PCC 18A.15.050(A)
Minimum lot size
Not set PCC 18A.15.050(B)(5)
Maximum lot size
Not set PCC 18A.15.050(B)(9)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
  2. The community plan area the lot is in (outside means not in an adopted community plan area) is one of alderton_mcmillin, browns_point_dash_point, frederickson, graham, outside, south_hill
  3. The housing will be occupied by persons who qualify as handicapped under the Federal Fair Housing Act
  4. None of these is true:
    • The housing will be occupied by persons who qualify as handicapped under the Federal Fair Housing Act
  5. The project is a low impact development project designed pursuant to the Pierce County Stormwater Management Manual and Site Development Manual, Volume VI
  6. All of these are true:
    • The site contains critical areas or their buffers, and critical area requirements with the average lot size would prevent a density of four dwelling units per net acre
    None of these is true:
    • The project is a low impact development project designed pursuant to the Pierce County Stormwater Management Manual and Site Development Manual, Volume VI
  7. None of these is true:
    • The project is a low impact development project designed pursuant to the Pierce County Stormwater Management Manual and Site Development Manual, Volume VI
    • The site contains critical areas or their buffers, and critical area requirements with the average lot size would prevent a density of four dwelling units per net acre
  8. All of these are true:
    • The lot was legally created
    • Any of these is true:
      • Lot area is less than 5,000 sf
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    None of these is true:
    • The project is a low impact development project designed pursuant to the Pierce County Stormwater Management Manual and Site Development Manual, Volume VI
  9. All of these are true:
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    • The site contains critical areas or their buffers, and critical area requirements with the average lot size would prevent a density of four dwelling units per net acre
    None of these is true:
    • The project is a low impact development project designed pursuant to the Pierce County Stormwater Management Manual and Site Development Manual, Volume VI
  10. All of these are true:
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    None of these is true:
    • The project is a low impact development project designed pursuant to the Pierce County Stormwater Management Manual and Site Development Manual, Volume VI
    • The site contains critical areas or their buffers, and critical area requirements with the average lot size would prevent a density of four dwelling units per net acre
  11. None of these is true:
    • The lot is within 300 feet of a sewer hook-up
  12. All of these are true:
    • The lot is within 300 feet of a sewer hook-up
    • Lot area is less than 43,560 sf
    • The lot contains an existing residential or commercial use
  13. All of these are true:
    • The lot is within 300 feet of a sewer hook-up
    • Not all of these are true:
      • Lot area is less than 43,560 sf
      • The lot contains an existing residential or commercial use
  14. Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_rental
  15. Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_owner_occupied
  16. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is below_20
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  17. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_20_to_50
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  18. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_50_to_75
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  19. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is above_75
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  20. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is below_20
  21. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_20_to_50
  22. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_50_to_75
  23. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is above_75
  24. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_rental
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
  25. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_owner_occupied
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
  26. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • The lot was legally created
    • Any of these is true:
      • Lot area is less than 5,000 sf
      • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
  27. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is below_20
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  28. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_20_to_50
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  29. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_50_to_75
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  30. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is above_75
    None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  31. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is below_20
  32. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_20_to_50
  33. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is from_50_to_75
  34. All of these are true:
    • Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
    • Not all of these are true:
      • The lot was legally created
      • Any of these is true:
        • Lot area is less than 5,000 sf
        • Lot area minus critical areas and buffers is less than 21,780 ÷ 4
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
    • Share of the site that is environmentally constrained land (Table 18A.15.020-3 rows) is above_75
  35. None of these is true:
    • The project meets the criteria in 18A.15.020.E to exceed Base Density
  36. The project meets the criteria in 18A.15.020.E to exceed Base Density
  37. The lot is a pipestem lot, or its only access is a shared access facility
  38. All of these are true:
    • A principal building has been established on an adjacent lot within the required front yard
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The adjacent lot has received a reduced setback based upon a discretionary land use approval
  39. All of these are true:
    • Not all of these are true:
      • A principal building has been established on an adjacent lot within the required front yard
      • None of these is true:
        • The adjacent lot has received a reduced setback based upon a discretionary land use approval
    • The front yard abuts an arterial
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  40. All of these are true:
    • Not all of these are true:
      • A principal building has been established on an adjacent lot within the required front yard
      • None of these is true:
        • The adjacent lot has received a reduced setback based upon a discretionary land use approval
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The front yard abuts an arterial
  41. All of these are true:
    • The lot is an existing lot of record
    • Lot width is at most 100 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  42. All of these are true:
    • The lot is an existing lot of record
    • Lot width is more than 100 ft
    • Lot width is at most 150 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  43. All of these are true:
    • The lot is an existing lot of record
    • Lot width is more than 150 ft
    • Lot width is at most 200 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  44. All of these are true:
    • Not all of these are true:
      • The lot is an existing lot of record
      • Lot width is at most 200 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  45. All of these are true:
    • The structures are attached
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  46. All of these are true:
    • The lot is an existing lot of record
    • Lot width is at most 100 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The structures are attached
  47. All of these are true:
    • The lot is an existing lot of record
    • Lot width is more than 100 ft
    • Lot width is at most 150 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The structures are attached
  48. All of these are true:
    • The lot is an existing lot of record
    • Lot width is more than 150 ft
    • Lot width is at most 200 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The structures are attached
  49. All of these are true:
    • Not all of these are true:
      • The lot is an existing lot of record
      • Lot width is at most 200 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The structures are attached
  50. All of these are true:
    • The front yard abuts an arterial
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  51. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The front yard abuts an arterial
  52. All of these are true:
    • In a land division, critical area or low impact development requirements would otherwise prevent minimum density from being achieved
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  53. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • In a land division, critical area or low impact development requirements would otherwise prevent minimum density from being achieved
  54. Within one-half mile of a major transit stop (RCW 36.70A.681)
  55. None of these is true:
    • Within one-half mile of a major transit stop (RCW 36.70A.681)
  56. All of these are true:
    • Bedrooms in one unit is at most 1
    • Within 1/2 mile of a high-capacity transit route
  57. All of these are true:
    • Bedrooms in one unit is at most 1
    None of these is true:
    • Within 1/2 mile of a high-capacity transit route
  58. Bedrooms in one unit is at least 2
  59. The dwelling is built on a residential infill lot created through an Infill Lot Subdivision
  60. None of these is true:
    • The dwelling is built on a residential infill lot created through an Infill Lot Subdivision
  61. All of these are true:
    • The ADU is detached from the principal structure
    • The separation between the principal structure and the ADU is less than 100 linear feet
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The ADU is created by converting an existing (pre-existing) detached structure
    • The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
  62. All of these are true:
    • Not all of these are true:
      • The ADU is detached from the principal structure
      • The separation between the principal structure and the ADU is less than 100 linear feet
      • None of these is true:
        • The ADU is created by converting an existing (pre-existing) detached structure
      • None of these is true:
        • The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
    • The front yard abuts an arterial
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  63. All of these are true:
    • Not all of these are true:
      • The ADU is detached from the principal structure
      • The separation between the principal structure and the ADU is less than 100 linear feet
      • None of these is true:
        • The ADU is created by converting an existing (pre-existing) detached structure
      • None of these is true:
        • The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The front yard abuts an arterial
  64. All of these are true:
    • The ADU is created by converting an existing (pre-existing) detached structure
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  65. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The ADU is created by converting an existing (pre-existing) detached structure
  66. All of these are true:
    • The ADU abuts an alley
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The ADU is created by converting an existing (pre-existing) detached structure
  67. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The ADU is created by converting an existing (pre-existing) detached structure
    • The ADU abuts an alley
  68. Lot area is at most 87,120 sf