Sign in

VC · Village Center

Pierce County, WA · PCC 18A.10.090(A)(2)(d) · Official code

By right: 1 unit, 2 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Mobile Home
Home✓ ADU—
————
Detached Single-Family Housing
Home✓ ADU✓1
————
Duplexes—
Home✓ ADU✓1
———
Mobile Home Park———
HomeH ADU—
—
Multi-Family Housing Level 1———
Home✓ ADU—
—
Multi-Family Housing Level 2———
Home✓2 ADU—
—
Senior Housing Level 2———
Home✓ ADU—
—
Group Home————
Home✓3 H4 ADU—
Residential Care Facility Level 1————
Home✓ ADU—
Residential Care Facility Level 2————
Home✓ ADU—
Senior Housing Level 1————
Home✓ ADU—
Employee Housing————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum unitsNot set PCC 18A.33.210
6 units PCC 18A.33.210(D)
for Multi-Family Housing Level 1 (4+ units)
Minimum lot sizeNot set PCC Table 18A.15.020-2
  • In any zone that permits a single-family dwelling unit, a single-family dwelling unit and permitted accessory structures may be constructed or enlarged on a lot which cannot satisfy the lot size and/or density requirements of the zone where the lot was legally created.5 PCC 18A.15.010(B)
  • Not set6 PCC Table 18A.15.020-2
for Detached Single-Family Housing (1 unit)
Minimum densityNot set PCC Table 18A.15.020-2
No limit PCC 18A.33.270(H)
for Employee Housing (group living)
Maximum densityThe residential densities in Rural Centers shall be the same as permitted in the adjacent rural designations except as follows: PCC 18A.15.020(A)(7)
  • In any zone that permits a single-family dwelling unit, a single-family dwelling unit and permitted accessory structures may be constructed or enlarged on a lot which cannot satisfy the lot size and/or density requirements of the zone where the lot was legally created.5 PCC 18A.15.010(B)
  • The residential densities in Rural Centers shall be the same as permitted in the adjacent rural designations except as follows:6 PCC 18A.15.020(A)(7)
for Detached Single-Family Housing (1 unit)
The densities for senior and assisted-living centers shall be based upon the requirements of the Health Department. PCC 18A.15.020(A)(7)(c)
for Senior Housing Level 2 (4+ units); Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living); Senior Housing Level 1 (group living)
Not set PCC 18A.15.020
for Group Home (group living)4; Group Home (group living)3
No limit PCC 18A.33.270(H)
for Employee Housing (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Averaging may be used to reduce a front setback requirement when a principal building has been established on an adjacent lot within the required yard. Averaging shall be calculated by adding the existing front setbacks of the adjacent lots together and dividing that figure by two. In the case of a corner lot or when an adjacent lot is vacant, averaging shall be calculated by adding the front setback of the adjacent developed lot with the minimum front setback of the zone in which the construction is proposed and dividing that figure by two.9 PCC 18A.15.040(B)(3)(b); 18A.15.040(B)(3)(b)(1); 18A.15.040(B)(3)(b)(2)
  • 0 ft10 PCC Table 18A.15.040-2
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Averaging may be used to reduce a front setback requirement when a principal building has been established on an adjacent lot within the required yard. Averaging shall be calculated by adding the existing front setbacks of the adjacent lots together and dividing that figure by two. In the case of a corner lot or when an adjacent lot is vacant, averaging shall be calculated by adding the front setback of the adjacent developed lot with the minimum front setback of the zone in which the construction is proposed and dividing that figure by two.9 PCC 18A.15.040(B)(3)(b); 18A.15.040(B)(3)(b)(1); 18A.15.040(B)(3)(b)(2)
  • 30 ft11 PCC 18A.15.040(B)(1)(c)
  • 0 ft12 PCC Table 18A.15.040-2
for Senior Housing Level 2 (4+ units); Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living); Senior Housing Level 1 (group living)
Side setback
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 0 ft13 PCC Table 18A.15.040-2
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • the smallest of 30, the largest of 3, 0.1 × lot width ft14 PCC 18A.15.040(B)(1)(c); PCC 18A.15.040(B)(4)(c)
  • the smallest of 30, the largest of 3, 0.15 × lot width ft15 PCC 18A.15.040(B)(1)(c); PCC 18A.15.040(B)(4)(c)
  • the smallest of 30, the largest of 3, 0.25 × lot width ft16 PCC 18A.15.040(B)(1)(c); PCC 18A.15.040(B)(4)(c)
  • 30 ft17 PCC 18A.15.040(B)(1)(c)
  • 0 ft18 PCC Table 18A.15.040-2
for Senior Housing Level 2 (4+ units); Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living); Senior Housing Level 1 (group living)
Street side setback
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 0 ft13 PCC 18A.15.040(A)(2)
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 30 ft19 PCC 18A.15.040(B)(1)(c)
  • 0 ft18 PCC 18A.15.040(A)(2)
for Senior Housing Level 2 (4+ units); Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living); Senior Housing Level 1 (group living)
Rear setback
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 0 ft13 PCC Table 18A.15.040-2
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • the largest of 25, 30 − (150 − lot depth) ft20 PCC 18A.15.040(B)(1)(c); PCC 18A.15.040(B)(5)(d)
  • 30 ft21 PCC 18A.15.040(B)(1)(c)
  • 0 ft18 PCC Table 18A.15.040-2
for Senior Housing Level 2 (4+ units); Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living); Senior Housing Level 1 (group living)
Maximum height40 ft PCC Table 18A.15.040-3
Minimum parking
  • 0 spaces per unit22 PCC Table 18A.35.040-1 note (3)
  • 0.5 × bedrooms in the whole project spaces23 PCC Table 18A.35.040-1
2 spaces per unit PCC Table 18A.35.040-1
for Mobile Home (1 unit); Detached Single-Family Housing (1 unit); Duplexes (2 units)
In the case of a land use not specifically mentioned in Table 18A.35.040-1, required off-street parking shall be determined by the approval authority. PCC 18A.35.040(E)
for Mobile Home Park (4+ units)
  • 1.5 spaces per unit24 PCC Table 18A.35.040-1
  • 2 spaces per unit25 PCC Table 18A.35.040-1
  • 2.25 spaces per unit26 PCC Table 18A.35.040-1
for Multi-Family Housing Level 1 (4+ units); Multi-Family Housing Level 2 (4+ units)2
(beds in the project ÷ 4) + (employees on the largest shift ÷ 2) spaces PCC Table 18A.35.040-1
for Residential Care Facility Level 1 (group living); Residential Care Facility Level 2 (group living)
1 per 2 units plus 1 per resident manager unit PCC Table 18A.35.040-1
for Employee Housing (group living)
Maximum lot size14,750 sq ft PCC Table 18A.15.020-2
Maximum units per buildingNot set PCC 18A.33.210
2 units PCC 18A.33.210(G)
for Duplexes (2 units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit PCC 18A.37.120(A)(1)

Building

StandardValueExceptions
Front setback
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • Detached ADUs shall be no closer to the front lot line than the closest point to the front lot line of the principal structure, unless the ADU was created by the conversion of a pre-existing structure into the ADU.27 PCC 18A.37.120(C)(1)
  • 0 ft28 PCC 18A.37.120(A)(4); Table 18A.15.040-2
Side setback
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 0 ft13 PCC Table 18A.15.040-2
Rear setback
  • 5 ft7 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 15 ft8 PCC 18A.15.040(B)(2)(b); 18A.15.040(B)(2)(c)
  • 0 ft13 PCC Table 18A.15.040-2
Maximum height40 ft PCC 18A.37.120(A)(5); Table 18A.15.040-3
Minimum parking
  • 0 spaces per unit22 PCC 18A.37.120(E)(1)(a); Table 18A.35.040-1 note (3)
  • 1 space per unit23 PCC Table 18A.35.040-1; 18A.37.120(E)(1)(b)
Maximum unit size1,250 sq ft PCC 18A.37.120(B)
Attached to the main houseNot required PCC 18A.37.120(A)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision PCC 18F.40.020 ✓ — The residential densities in Rural Centers shall be the same as permitted in the adjacent rural designations except as follows: PCC 18A.15.020(A)(7)
Minimum lot size
Not set PCC Table 18A.15.020-2
Maximum lot size
14,750 sq ft PCC Table 18A.15.020-2
Minimum lot width
Not set PCC Table 18A.15.020-2
Short subdivision PCC 18F.50.040(E) A — The residential densities in Rural Centers shall be the same as permitted in the adjacent rural designations except as follows: PCC 18A.15.020(A)(7)
Minimum lot size
Not set PCC Table 18A.15.020-2
Maximum lot size
14,750 sq ft PCC Table 18A.15.020-2
Minimum lot width
Not set PCC Table 18A.15.020-2
Large lot division PCC 18F.50.040(E) A — The residential densities in Rural Centers shall be the same as permitted in the adjacent rural designations except as follows: PCC 18A.15.020(A)(7)
Minimum lot size
Not set PCC Table 18A.15.020-2
Maximum lot size
14,750 sq ft PCC Table 18A.15.020-2
Minimum lot width
Not set PCC Table 18A.15.020-2
Binding Site Plan PCC 18F.60.030(B); 18F.60.030(D) A29 — The residential densities in Rural Centers shall be the same as permitted in the adjacent rural designations except as follows: PCC 18A.15.020(A)(7)
Minimum lot size
Not set PCC 18F.60.030
Maximum lot size
14,750 sq ft PCC Table 18A.15.020-2

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is none
  2. Dwelling units are in a mixed-use building above nonresidential activity on the first floor
  3. The housing will be occupied by persons who qualify as handicapped under the Federal Fair Housing Act
  4. None of these is true:
    • The housing will be occupied by persons who qualify as handicapped under the Federal Fair Housing Act
  5. The lot was legally created
  6. None of these is true:
    • The lot was legally created
  7. All of these are true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • Lot area is at most 21,780 sf
  8. All of these are true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • Lot area is more than 21,780 sf
  9. All of these are true:
    • A principal building has been established on an adjacent lot within the required front yard
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The adjacent lot has received a reduced setback based upon a discretionary land use approval
  10. All of these are true:
    • Not all of these are true:
      • A principal building has been established on an adjacent lot within the required front yard
      • None of these is true:
        • The adjacent lot has received a reduced setback based upon a discretionary land use approval
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  11. All of these are true:
    • Not all of these are true:
      • A principal building has been established on an adjacent lot within the required front yard
      • None of these is true:
        • The adjacent lot has received a reduced setback based upon a discretionary land use approval
    • A lot line abuts an R5, R10, R20 or R40 zone classification (the setback along that line)
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  12. All of these are true:
    • Not all of these are true:
      • A principal building has been established on an adjacent lot within the required front yard
      • None of these is true:
        • The adjacent lot has received a reduced setback based upon a discretionary land use approval
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • A lot line abuts an R5, R10, R20 or R40 zone classification (the setback along that line)
  13. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  14. All of these are true:
    • A lot line abuts an R5, R10, R20 or R40 zone classification (the setback along that line)
    • The lot is an existing lot of record
    • Lot width is at most 100 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  15. All of these are true:
    • A lot line abuts an R5, R10, R20 or R40 zone classification (the setback along that line)
    • The lot is an existing lot of record
    • Lot width is more than 100 ft
    • Lot width is at most 150 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  16. All of these are true:
    • A lot line abuts an R5, R10, R20 or R40 zone classification (the setback along that line)
    • The lot is an existing lot of record
    • Lot width is more than 150 ft
    • Lot width is at most 200 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  17. All of these are true:
    • A lot line abuts an R5, R10, R20 or R40 zone classification (the setback along that line)
    • Not all of these are true:
      • The lot is an existing lot of record
      • Lot width is at most 200 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  18. None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • A lot line abuts an R5, R10, R20 or R40 zone classification (the setback along that line)
  19. All of these are true:
    • A lot line abuts an R5, R10, R20 or R40 zone classification (the setback along that line)
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  20. All of these are true:
    • A lot line abuts an R5, R10, R20 or R40 zone classification (the setback along that line)
    • The lot is an existing lot of record
    • Lot depth is less than 150 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  21. All of these are true:
    • A lot line abuts an R5, R10, R20 or R40 zone classification (the setback along that line)
    • Not all of these are true:
      • The lot is an existing lot of record
      • Lot depth is less than 150 ft
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  22. Within one-half mile of a major transit stop (RCW 36.70A.681)
  23. None of these is true:
    • Within one-half mile of a major transit stop (RCW 36.70A.681)
  24. Bedrooms in one unit is at most 1
  25. All of these are true:
    • Bedrooms in one unit is at least 2
    • Bedrooms in one unit is less than 3
  26. Bedrooms in one unit is at least 3
  27. All of these are true:
    • The ADU is detached from the principal structure
    • The separation between the principal structure and the ADU is less than 100 linear feet
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
    • The ADU is created by converting an existing (pre-existing) detached structure
    • The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
  28. All of these are true:
    • Not all of these are true:
      • The ADU is detached from the principal structure
      • The separation between the principal structure and the ADU is less than 100 linear feet
      • None of these is true:
        • The ADU is created by converting an existing (pre-existing) detached structure
      • None of these is true:
        • The lot is a waterfront lot regulated under Title 18S PCC (Shorelines)
    None of these is true:
    • The lot is a pipestem lot, or its only access is a shared access facility
  29. Any of these is true:
    • The land is divided for sale or lease into lots classified for commercial or industrial uses
    • The division is for the development of condominium units under Chapter 64.34 RCW