Sign in

BP · Business park (BP)

Poulsbo, WA · PMC 18.90 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Mixed-use structure
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Live/work units
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Planned mixed-use developments (PMUD)—
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
—
Nursing home————
Home✓3 ADU—
Residential care facility————
Home✓3 ADU—
Assisted living————
Home✓3 ADU—
Congregate care senior housing————
Home✓3 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit PMC 18.90.040

3. Building standards

StandardValueExceptions
Front setback
  • 20 ft4 PMC 18.90.040
  • 10 ft5 PMC 18.90.040
Side setback
  • 20 ft4 PMC 18.90.040
  • 5 ft5 PMC 18.90.040
Street side setback
  • 20 ft4 PMC 18.90.040
  • 10 ft5 PMC 18.90.040
Rear setback
  • 20 ft4 PMC 18.90.040
  • 5 ft5 PMC 18.90.040
Maximum height
  • 45 + 10 ft6 PMC 18.90.040; 18.310.010(C)
  • 45 ft7 PMC 18.90.040
  • 55 + 10 ft8 PMC 18.90.040; 18.310.010(C)
  • 55 ft9 PMC 18.90.040
  • 35 + 10 ft10 PMC 18.90.040; 18.310.010(C)
  • 35 ft11 PMC 18.90.040
Maximum lot coverageAs provided after setbacks, landscaping, parking and other applicable standards are met. PMC 18.90.040
Minimum parking
  • 1.25 + (1 ÷ 10) spaces per unit12 PMC 18.90.090(A)(8)(d); 18.90.090(A)(8)(c)
  • 1 + (1 ÷ 10) spaces per unit13 PMC 18.90.090(A)(8)(a); 18.90.090(A)(8)(c)
  • 1.5 + (1 ÷ 10) spaces per unit14 PMC 18.90.090(A)(8)(b); 18.90.090(A)(8)(c)
Live/work: one space per residential unit plus one space per five hundred gsf of nonresidential area. PMC 18.90.090(A)(8)(f)
for Live/work units (1, 2, 3, 4+ units)
Other uses not specifically listed shall furnish parking as required by the director based upon the most analogous use. PMC 18.90.090(A)(11)
for Nursing home (group living)3
(beds in the project ÷ 4) + (employees on the largest shift ÷ 2) spaces PMC 18.90.090(A)(8)(e)
for Residential care facility (group living)3; Assisted living (group living)3; Congregate care senior housing (group living)3
Maximum unit sizeNot set PMC 18.90.040
3,000 sq ft PMC 18.90.070(B)(1)
for Live/work units (1, 2, 3, 4+ units)
Minimum open space20% PMC 18.90.050(A)(1)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Binding site plan PMC 17.50.030; 17.50.020(A) A — Not set PMC 18.90.040
Minimum lot size
No limit PMC 18.90.040; 17.80.010(D)
Short subdivision PMC 17.40.020(A) A up to 4 PMC 17.40.020(A); 17.20.010 Not set PMC 18.90.040
Minimum lot size
No limit PMC 18.90.040; 17.40.020(B); 17.60.020(B)
Subdivision (preliminary subdivision) PMC 17.60.020(A) H 5 or more PMC 17.20.010 Not set PMC 18.90.040
Minimum lot size
No limit PMC 18.90.040; 17.40.020(B); 17.60.020(B)
Unit lot subdivision PMC 17.65.060; 17.65.020(A)Only for: Planned mixed-use developments (PMUD), Mixed-use structure A — Not set PMC 18.90.040; 17.65.020(D)
Minimum lot size
No limit PMC 17.65.020(B)
Maximum units per lot
1 unit PMC 17.65.020(D)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Residential units are in a mixed-use structure that contains at least one other complementary, integrated or mutually supporting use (such as offices, retail or services)
  2. Project is a planned mixed-use development in which residential and commercial uses each make up at least 20% of the buildings' gross square footage
  3. The use is associated with a mixed-use structure or PMUD
  4. The lot line is adjacent to an R zoning district; the larger setback applies on that side
  5. None of these is true:
    • The lot line is adjacent to an R zoning district; the larger setback applies on that side
  6. All of these are true:
    • Lot is in business and employment height area 1 on the map in 18.90.040
    • The structure includes underbuilding parking (height bonus of 10 feet)
  7. All of these are true:
    • Lot is in business and employment height area 1 on the map in 18.90.040
    None of these is true:
    • The structure includes underbuilding parking (height bonus of 10 feet)
  8. All of these are true:
    • Lot is in business and employment height area 2 on the map in 18.90.040
    • The structure includes underbuilding parking (height bonus of 10 feet)
  9. All of these are true:
    • Lot is in business and employment height area 2 on the map in 18.90.040
    None of these is true:
    • The structure includes underbuilding parking (height bonus of 10 feet)
  10. All of these are true:
    • The structure includes underbuilding parking (height bonus of 10 feet)
    None of these is true:
    • Lot is in business and employment height area 1 on the map in 18.90.040
    • Lot is in business and employment height area 2 on the map in 18.90.040
  11. None of these is true:
    • Lot is in business and employment height area 1 on the map in 18.90.040
    • Lot is in business and employment height area 2 on the map in 18.90.040
    • The structure includes underbuilding parking (height bonus of 10 feet)
  12. Residential units are restricted to use for seniors (sixty-five years and older)
  13. All of these are true:
    • Bedrooms in one unit is at most 1
    None of these is true:
    • Residential units are restricted to use for seniors (sixty-five years and older)
  14. All of these are true:
    • Bedrooms in one unit is at least 2
    None of these is true:
    • Residential units are restricted to use for seniors (sixty-five years and older)