RH · Residential high (RH)
Poulsbo, WA · PMC 18.70 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, single-family | Home✓ ADU✓ | — | — | — | — |
| Manufactured home, designated | Home✓ ADU✓ | — | — | — | — |
| Mobile home | Home✓ ADU✓ | — | — | — | — |
| Live/work units | HomeA ADU— | HomeA ADU— | HomeA ADU— | HomeA ADU— | — |
| Duplex on corner lot | — | — | — | — | |
| Dwelling, multifamily | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Cottage housing | — | — | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Manufactured home parks/subdivisions | — | — | — | HomeH ADU— | — |
| Adult family home | — | — | — | — | Home✓ ADU✓ |
| Group residential home | — | — | — | — | Home✓ ADU✓ |
| Group home | — | — | — | — | Home✓ ADU✓ |
| Residential care home | — | — | — | — | Home✓ ADU✓ |
| Boarding or rooming houses | — | — | — | — | Home✓ ADU— |
| Dormitory | — | — | — | — | Home✓ ADU— |
| Confidential shelter (including confidential transition homes) | — | — | — | — | Home✓ ADU— |
| Emergency shelter | — | — | — | — | |
| Emergency housing | — | — | — | — | HomeA ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | |
| Assisted living | — | — | — | — | Home✓ ADU— |
| Congregate care senior housing | — | — | — | — | Home✓ ADU— |
| Nursing home | — | — | — | — | HomeA ADU— |
| Residential care facility | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | No limit PMC 18.70.060(A) | for Dwelling, single-family (1 unit); Manufactured home, designated (1 unit); Mobile home (1 unit); Duplex on corner lot (2 units)1; Adult family home (group living); Group residential home (group living); Group home (group living); Residential care home (group living) 0.5 × 43,560 sq ft PMC 18.70.070(K)(3)(b)
for Cottage housing (3, 4+ units) 3,000 sq ft PMC 18.70.070(U)(3)
for Manufactured home parks/subdivisions (4+ units) |
| Minimum lot width | 20 ft PMC 18.70.060(A) | for Dwelling, single-family (1 unit); Manufactured home, designated (1 unit); Mobile home (1 unit); Duplex on corner lot (2 units)1; Adult family home (group living); Group residential home (group living); Group home (group living); Residential care home (group living) Not set PMC 18.70.070(K)(3)(b)
for Cottage housing (3, 4+ units) 40 ft PMC 18.70.070(U)(3)
for Manufactured home parks/subdivisions (4+ units) |
| Minimum density | Not set PMC 18.70.040 | Legal lots of record that do not meet the minimum density requirements may be developed with a single dwelling unit; provided, that if the lot is of a size that can be further subdivided in the future based on the minimum lot size requirements of the applicable residential zone, the dwelling unit must be located so not to prevent future subdivision from occurring that meets all of the city’s lot dimensional requirements. PMC 18.70.040(C)(4)
for Dwelling, single-family (1 unit); Manufactured home, designated (1 unit); Mobile home (1 unit) 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1)
for Live/work units (1, 2, 3, 4+ units); Duplex on corner lot (2 units)1; Dwelling, multifamily (2, 3, 4+ units); Cottage housing (3, 4+ units); Manufactured home parks/subdivisions (4+ units) |
| Maximum density | 22 units per acre, a fraction of 0.5 or more rounds up PMC 18.70.040(A); 18.70.040(B)(2); 18.70.040(C)(5) | 2 × 22 units per acre, a fraction of 0.5 or more rounds up PMC 18.70.040(A); 18.70.040(B)(2); 18.70.040(C)(5); 18.70.070(H)(1)(a)
for Duplex on corner lot (2 units)1
for Dwelling, multifamily (4+ units); Cottage housing (4+ units); Manufactured home parks/subdivisions (4+ units) Not set PMC 18.70.040
for Adult family home (group living); Group residential home (group living); Group home (group living); Residential care home (group living); Boarding or rooming houses (group living); Dormitory (group living); Confidential shelter (including confidential transition homes) (group living); Emergency shelter (group living)2; Emergency housing (group living) The units associated with assisted living, congregate care, nursing home, residential care facilities and the like, that rely on shared cooking/dining facilities, will not be counted for purposes of the minimum/maximum density calculation. Independent dwelling units (i.e., containing a bed, bathroom, and a kitchen with a sink, stove, and refrigerator) in such group living residential uses, however, shall be counted as individual dwelling units in the density calculation. PMC 18.70.040(B)(3)
for Assisted living (group living); Congregate care senior housing (group living); Nursing home (group living); Residential care facility (group living) |
| Minimum development size | Not set PMC 18.70.060(A) | 3 × 43,560 sq ft PMC 18.70.070(U)(1)
for Manufactured home parks/subdivisions (4+ units) |
| Maximum residents | Not set PMC 18.70.060 | 6 persons PMC 18.40.030
for Adult family home (group living); Group residential home (group living); Residential care home (group living) 40 persons PMC 18.70.070(I)(3)
for Emergency shelter (group living)2 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft PMC 18.70.060(A) | for Dwelling, single-family (1 unit); Manufactured home, designated (1 unit); Mobile home (1 unit); Duplex on corner lot (2 units)1; Adult family home (group living); Group residential home (group living); Group home (group living); Residential care home (group living) |
| Side setback | for Dwelling, single-family (1 unit); Manufactured home, designated (1 unit); Mobile home (1 unit); Adult family home (group living); Group residential home (group living); Group home (group living); Residential care home (group living) 5 ft PMC 18.70.060(A); 18.70.070(H)(1)(b)
for Duplex on corner lot (2 units)1 10 ft PMC 18.70.070(U)(7)
for Manufactured home parks/subdivisions (4+ units) | |
| Street side setback | 10 ft PMC 18.70.060(A); 18.260.050 | |
| Rear setback | for Dwelling, single-family (1 unit); Manufactured home, designated (1 unit); Mobile home (1 unit); Duplex on corner lot (2 units)1; Adult family home (group living); Group residential home (group living); Group home (group living); Residential care home (group living) 10 ft PMC 18.70.070(U)(7)
for Manufactured home parks/subdivisions (4+ units) | |
| Building separation | Not set PMC 18.70.060
for Dwelling, single-family (1 unit); Manufactured home, designated (1 unit); Mobile home (1 unit); Duplex on corner lot (2 units)1; Adult family home (group living); Group residential home (group living); Group home (group living); Residential care home (group living) 10 ft PMC 18.70.070(K)(3)(b)
for Cottage housing (3, 4+ units); Manufactured home parks/subdivisions (4+ units) | |
| Maximum height | 25 ft PMC 18.70.070(K)(3)(b); 18.70.070(K)(5)(a)
for Cottage housing (3, 4+ units) | |
| Maximum lot coverage | 60% PMC 18.70.060(A) | for Dwelling, single-family (1 unit); Manufactured home, designated (1 unit); Mobile home (1 unit); Duplex on corner lot (2 units)1; Adult family home (group living); Group residential home (group living); Group home (group living); Residential care home (group living) |
| Minimum parking | 2 spaces per unit PMC 18.70.080(A)(1) | Live/work units: one and one-half spaces per residential unit, plus additional customer/client and employee spaces determined at the time of project review. PMC 18.70.080(E)
for Live/work units (1, 2, 3, 4+ units) Other uses not specifically listed shall furnish parking as required by the planning director based upon the most analogous use. PMC 18.70.080(K)
for Adult family home (group living); Group residential home (group living); Group home (group living); Residential care home (group living); Dormitory (group living); Nursing home (group living) sleeping units in the project + employees on the largest shift spaces PMC 18.70.080(A)(5)
for Boarding or rooming houses (group living) (beds in the project ÷ 4) + employees on the largest shift spaces PMC 18.70.080(A)(7)
(beds in the project ÷ 2) + (employees on the largest shift ÷ 2) spaces PMC 18.70.080(B)
for Assisted living (group living); Congregate care senior housing (group living); Residential care facility (group living) |
| Maximum unit size | Not set PMC 18.70.060 | 3,000 sq ft PMC 18.70.070(F)(5)(a)
for Live/work units (1, 2, 3, 4+ units) |
| Minimum open space | 20% PMC 18.70.060(E)(1)(a) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units PMC 18.70.070(A)(2) | 2 × main dwelling units on the lot units PMC 18.70.070(A)(2)
for Duplex on corner lot (2 units)1; Dwelling, multifamily (2, 3, 4+ units); Cottage housing (3, 4+ units) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft PMC 18.70.060(A)
for Dwelling, multifamily (2, 3, 4+ units) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Minimum parking | ||
| Maximum unit size | ||
| Attached to the main house | Not required PMC 18.70.070(A)(3)(c) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision PMC 17.40.020(A)Only for: Dwelling, single-family, Manufactured home, designated, Mobile home, Duplex on corner lot | A | up to 4 PMC 17.40.020(A); 17.20.010 | 22 units per acre, a fraction of 0.5 or more rounds up PMC 18.70.040(A); 18.70.040(B)(2); 18.70.040(C)(2); 18.70.040(C)(5) Minimum density 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1); 18.70.040(C)(2) |
Minimum lot size 4,000 sq ft PMC 18.70.060(A); 17.40.020(B); 17.60.020(B) Minimum lot width 50 ft PMC 18.70.060(A) |
| Short subdivision PMC 17.40.020(A)Only for: Dwelling, multifamily, Live/work units | A | up to 4 PMC 17.40.020(A); 17.20.010 | 22 units per acre, a fraction of 0.5 or more rounds up PMC 18.70.040(A); 18.70.040(B)(2); 18.70.040(C)(2); 18.70.040(C)(5) Minimum density 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1); 18.70.040(C)(2) |
Minimum lot size No limit PMC 18.70.060(A); 17.40.020(B); 17.60.020(B) Minimum lot width 20 ft PMC 18.70.060(A) |
| Short subdivision PMC 17.40.020(A)Only for: Cottage housing | A | up to 4 PMC 17.40.020(A); 17.20.010 | 22 units per acre, a fraction of 0.5 or more rounds up PMC 18.70.040(A); 18.70.040(B)(2); 18.70.040(C)(2); 18.70.040(C)(5) Minimum density 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1); 18.70.040(C)(2) |
Minimum lot size 3,000 sq ft PMC 18.70.070(K)(3)(b) Minimum lot width 20 ft PMC 18.70.070(K)(3)(b) |
| Subdivision (preliminary subdivision) PMC 17.60.020(A)Only for: Dwelling, single-family, Manufactured home, designated, Mobile home, Duplex on corner lot | H | 5 or more PMC 17.20.010 | 22 units per acre, a fraction of 0.5 or more rounds up PMC 18.70.040(A); 18.70.040(B)(2); 18.70.040(C)(2); 18.70.040(C)(5) Minimum density 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1); 18.70.040(C)(2) |
Minimum lot size 4,000 sq ft PMC 18.70.060(A); 17.40.020(B); 17.60.020(B) Minimum lot width 50 ft PMC 18.70.060(A) |
| Subdivision (preliminary subdivision) PMC 17.60.020(A)Only for: Dwelling, multifamily, Live/work units | H | 5 or more PMC 17.20.010 | 22 units per acre, a fraction of 0.5 or more rounds up PMC 18.70.040(A); 18.70.040(B)(2); 18.70.040(C)(2); 18.70.040(C)(5) Minimum density 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1); 18.70.040(C)(2) |
Minimum lot size No limit PMC 18.70.060(A); 17.40.020(B); 17.60.020(B) Minimum lot width 20 ft PMC 18.70.060(A) |
| Subdivision (preliminary subdivision) PMC 17.60.020(A)Only for: Cottage housing | H | 5 or more PMC 17.20.010 | 22 units per acre, a fraction of 0.5 or more rounds up PMC 18.70.040(A); 18.70.040(B)(2); 18.70.040(C)(2); 18.70.040(C)(5) Minimum density 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1); 18.70.040(C)(2) |
Minimum lot size 3,000 sq ft PMC 18.70.070(K)(3)(b) Minimum lot width 20 ft PMC 18.70.070(K)(3)(b) |
| Planned residential developments PMC 18.70.030; 18.260.020Only for: Dwelling, single-family, Manufactured home, designated, Mobile home, Duplex on corner lot, Cottage housing | H | — |
Minimum parent area Except as set forth below, a tract of land to be developed as a planned residential development shall have a minimum of three acres. However, a smaller site size may be allowed if the review authority makes specific findings to support the conclusion that a planned residential development is in the public interest because one or more of the following conditions apply: PMC 18.260.040 Minimum density 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1); 18.70.040(C)(2) |
Minimum lot size 3,000 sq ft PMC 18.260.050 Minimum lot width 20 ft PMC 18.260.050 |
| Planned residential developments PMC 18.70.030; 18.260.020Only for: Dwelling, multifamily | H | — |
Minimum parent area Except as set forth below, a tract of land to be developed as a planned residential development shall have a minimum of three acres. However, a smaller site size may be allowed if the review authority makes specific findings to support the conclusion that a planned residential development is in the public interest because one or more of the following conditions apply: PMC 18.260.040 Minimum density 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1); 18.70.040(C)(2) |
Minimum lot size No limit PMC 18.260.050 Minimum lot width 20 ft PMC 18.260.050 |
| Binding site plan PMC 17.50.030; 17.50.020(C)Only for: Dwelling, multifamily, Cottage housing | A32 | — | 22 units per acre, a fraction of 0.5 or more rounds up PMC 18.70.040(A); 18.70.040(B)(2); 18.70.040(C)(2); 18.70.040(C)(5) Minimum density 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1); 18.70.040(C)(2) |
Minimum lot size No limit PMC 17.80.010(D); 18.70.060(A) |
| Unit lot subdivision PMC 17.65.060; 17.65.020(A); 18.70.070(H)(5)Only for: Dwelling, single-family, Manufactured home, designated, Mobile home, Dwelling, multifamily, Cottage housing, Manufactured home parks/subdivisions, Duplex on corner lot | A | — | 22 units per acre, a fraction of 0.5 or more rounds up, on the net lot area PMC 17.65.020(D); 18.70.040(A); 18.70.040(C)(5) Minimum density 16 units per acre PMC 18.70.040(A); 18.70.040(B)(1); 18.70.040(C)(2) |
Minimum lot size No limit PMC 17.65.020(B) Maximum units per lot 1 unit PMC 17.65.020(D) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Lot is a corner lot: a lot abutting upon two or more streets at their intersection
- None of these is true:
- All of these are true:
- The emergency shelter is continuously operating (not a temporary response to a natural disaster or similar acute emergency)
- Lot is within half a mile of a continuously operating emergency housing facility
- Lot is within half a mile of a property that contains permanent supportive housing
- Lot is within half a mile of a property that contains transitional housing
- All of these are true:
- None of these is true:
- Lot is within half a mile of a property that contains permanent supportive housing
- Lot is within half a mile of a property that contains transitional housing
- Lot is within half a mile of emergency housing
- Lot is within half a mile of an emergency shelter
- Project is developed through a planned residential development (PRD) under Chapter 18.260
- None of these is true:
- Project is developed through a planned residential development (PRD) under Chapter 18.260
- Density bonus the project uses: none; affordable housing bonus with 10% or 15% of the pre-bonus units affordable to low income households; or PRD public benefit incentives (up to a 25% increase) is not one of affordable_ten_percent, affordable_fifteen_percent
- Density bonus the project uses: none; affordable housing bonus with 10% or 15% of the pre-bonus units affordable to low income households; or PRD public benefit incentives (up to a 25% increase) is affordable_ten_percent
- Density bonus the project uses: none; affordable housing bonus with 10% or 15% of the pre-bonus units affordable to low income households; or PRD public benefit incentives (up to a 25% increase) is affordable_fifteen_percent
- The lot line (or the site perimeter) abuts or is adjacent to an RL zone; the larger setback applies on that side
- None of these is true:
- The lot line (or the site perimeter) abuts or is adjacent to an RL zone; the larger setback applies on that side
- Building height is more than 25
- Building height is at most 25
- The structure includes underbuilding parking (height bonus of 10 feet)
- All of these are true:
- Roof pitch of the building: under 4:12 (including shed roofs), at least 4:12, or at least 6:12 is under_4_12
- The structure includes underbuilding parking (height bonus of 10 feet)
- All of these are true:
- Roof pitch of the building: under 4:12 (including shed roofs), at least 4:12, or at least 6:12 is at_least_4_12
- The structure includes underbuilding parking (height bonus of 10 feet)
- All of these are true:
- Roof pitch of the building: under 4:12 (including shed roofs), at least 4:12, or at least 6:12 is at_least_6_12
- The structure includes underbuilding parking (height bonus of 10 feet)
- Residential units are restricted to use for seniors (sixty-five years and older)
- All of these are true:
- Bedrooms in one unit is at most 0
- Residential units are restricted to use for seniors (sixty-five years and older)
- All of these are true:
- Bedrooms in one unit is more than 0
- Residential units are restricted to use for seniors (sixty-five years and older)
- The ADU is detached from the principal unit
- All of these are true:
- The structure includes underbuilding parking (height bonus of 10 feet)
- The ADU is detached from the principal unit
- All of these are true:
- Roof pitch of the building: under 4:12 (including shed roofs), at least 4:12, or at least 6:12 is under_4_12
- The ADU is detached from the principal unit
- The structure includes underbuilding parking (height bonus of 10 feet)
- All of these are true:
- Roof pitch of the building: under 4:12 (including shed roofs), at least 4:12, or at least 6:12 is at_least_4_12
- The ADU is detached from the principal unit
- The structure includes underbuilding parking (height bonus of 10 feet)
- All of these are true:
- Roof pitch of the building: under 4:12 (including shed roofs), at least 4:12, or at least 6:12 is at_least_6_12
- The ADU is detached from the principal unit
- The structure includes underbuilding parking (height bonus of 10 feet)
- None of these is true:
- The ADU is detached from the principal unit
- Lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- Lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- The ADU is completely located on a ground floor or basement of the principal unit
- The ADU is completely located on a ground floor or basement of the principal unit
- Density bonus the project uses: none; affordable housing bonus with 10% or 15% of the pre-bonus units affordable to low income households; or PRD public benefit incentives (up to a 25% increase) is not one of affordable_ten_percent, affordable_fifteen_percent, prd_incentives
- Density bonus the project uses: none; affordable housing bonus with 10% or 15% of the pre-bonus units affordable to low income households; or PRD public benefit incentives (up to a 25% increase) is one of affordable_fifteen_percent, prd_incentives
- The land is divided under the Horizontal Properties Regimes Act (Chapter 64.32 RCW) or the Condominium Act (Chapter 64.34 RCW)