ARO · Agriculture, recreation and open space zone
Puyallup, WA · PMC 20.36 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, single-family | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 435,600 sq ft PMC 20.36.020(1) | |
| Minimum lot width | 250 ft PMC 20.36.020(1) | |
| Maximum density | 0.1 units per acre PMC 20.36.020(1) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 30 ft PMC 20.36.020(1) | |
| Side setback | 30 ft PMC 20.36.020(1) | |
| Rear setback | 30 ft PMC 20.36.020(1) | |
| Maximum height | 40 ft PMC 20.36.020(1) | |
| Maximum impervious surface | The maximum impervious surface area shall not exceed the greater of 5,000 square feet or five percent of any lot PMC 20.36.020(11) | |
| Minimum parking | 2 spaces per unit PMC 20.36.020(12); 20.55.010(9) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit PMC 20.36.020(3) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 30 ft PMC 20.36.020(1) | |
| Side setback | 30 ft PMC 20.36.020(1) | |
| Rear setback | 30 ft PMC 20.36.020(1) | |
| Maximum height | 40 ft PMC 20.36.020(1) | |
| Minimum parking |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, short PMC 19.07.100(1) | A | up to 9 PMC 19.07.020 | — | Minimum lot size 435,600 sq ft PMC 20.36.020(1) Minimum lot width 250 ft PMC 20.36.020(1) |
| Subdivision, major PMC 19.08.120 | H | 10 or more PMC 19.08.010 | — | Minimum lot size 435,600 sq ft PMC 20.36.020(1) Minimum lot width 250 ft PMC 20.36.020(1) |
| Unit lot subdivision PMC 19.11.020(1)(a) | A | 2 or more PMC 19.04.210 | — | Minimum lot size Unit lot(s) are not subject to PMC Title 20 dimensional standards of the applicable zoning district but shall meet the applicable building fire separation standards, fire access, adequacy of emergency vehicle access and fire protection water system standards. PMC 19.11.030(1)(d) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The residence is occupied by those engaged in agriculture on the property or operating a stable on the property
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is less than 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is more than 6,000 sf
- Bedrooms in one ADU is at most 1
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is more than 6,000 sf
- Bedrooms in one ADU is at least 2
- Lot is within one-half mile walking distance of a major transit stop