Sign in

UCX · Urban center mixed-use zone

Puyallup, WA · PMC 20.31 · Official code

By right: 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, multiple-family——
Home✓ ADU—
Home✓ ADU—
—
Townhouse——
Home✓ ADU—
Home✓ ADU—
—
Retirement apartments———
Home✓ ADU—
—
Senior housing complex———
Home✓ ADU—
—
Co-living————
Home✓ ADU—
Transitional housing————
Home✓ ADU—
Permanent supportive housing————
Home✓ ADU—
Emergency housing, scattered site units————
Home✓ ADU—
Emergency shelter, scattered site units————
Home✓ ADU—
Emergency housing, congregate————
HomeH ADU—
Emergency shelter, congregate————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum density8 units per acre PMC 20.31.020(2)
Not set PMC 20.29.025
for Co-living (group living)
Maximum densityNo limit PMC 20.31.020(2)
Maximum residentsNot set PMC 20.31.026
30 persons PMC 20.72.050(5)
for Emergency housing, congregate (group living); Emergency shelter, congregate (group living)
Maximum sleeping unitsNot set PMC 20.31.026
No limit PMC 20.31.020(2)
for Co-living (group living)

3. Building standards

StandardValueExceptions
Front setback12 ft PMC 20.31.026(3); 20.31.027(2)(c)
Maximum front setback20 ft PMC 20.31.026(3); 20.31.027(2)(c)(i)
Side setback6 ft PMC 20.31.026(4)
Street side setback12 ft PMC 20.31.026(5); 20.31.027(2)(c)
Rear setback10 ft PMC 20.31.026(6)
Maximum height
  • 54 ft1 PMC 20.31.028(2)
  • 82 ft2 PMC 20.31.028(2)-(3)
  • 68 ft3 PMC 20.31.028(2); 20.31.026(7)
  • 90 ft4 PMC 20.31.026(7); 20.31.028(3)
Maximum lot coverage65% PMC 20.31.026(9)
Minimum parking1 space per unit PMC 20.31.030(3)
  • 0 spaces per sleeping unit5 PMC 20.29.035(1)
  • 0.25 spaces per sleeping unit6 PMC 20.29.035(2)
for Co-living (group living)
Maximum unit sizeNot set PMC 20.31.026
300 sq ft PMC 20.29.020(1)(a)
for Co-living (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision, short PMC 19.07.100(1) A up to 9 PMC 19.07.020 —
Minimum lot size
Not set PMC 20.31.026
Subdivision, major PMC 19.08.120 H 10 or more PMC 19.08.010 —
Minimum lot size
Not set PMC 20.31.026
Unit lot subdivision PMC 19.11.020(1)(a) A 2 or more PMC 19.04.210 —
Minimum lot size
Unit lot(s) are not subject to PMC Title 20 dimensional standards of the applicable zoning district but shall meet the applicable building fire separation standards, fire access, adequacy of emergency vehicle access and fire protection water system standards. PMC 19.11.030(1)(d)
Binding site plan PMC 19.10.060(2) A 2 or more PMC 19.04.020 —
Minimum lot size
Not set PMC 20.31.026

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • Building site is within 300 feet of a single-family residential zone
    None of these is true:
    • Building site is separated from the single-family residential zone by an arterial
    • Project provides structured parking equal to at least 60% of the building footprint
  2. All of these are true:
    • Building site is within 300 feet of a single-family residential zone
    • Project provides structured parking equal to at least 60% of the building footprint
    None of these is true:
    • Building site is separated from the single-family residential zone by an arterial
  3. All of these are true:
    • Any of these is true:
      • None of these is true:
        • Building site is within 300 feet of a single-family residential zone
      • Building site is separated from the single-family residential zone by an arterial
    None of these is true:
    • Project provides structured parking equal to at least 60% of the building footprint
  4. All of these are true:
    • Any of these is true:
      • None of these is true:
        • Building site is within 300 feet of a single-family residential zone
      • Building site is separated from the single-family residential zone by an arterial
    • Project provides structured parking equal to at least 60% of the building footprint
  5. Lot is within one-half mile walking distance of a major transit stop
  6. None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop