Sign in

R8/25 · Residential 8-25 (R 8-25) zone

Rainier, WA · RMC 18.41; 18.41.030 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached Single-Family Unit
Home✓ ADUA1
————
Attached Single-Family Unit—
Home✓ ADUA1
Home✓ ADUA1
Home✓ ADUA1
—
Apartment—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Group Home————
Home✓ ADU—
Co-Living Housing————
Home✓ ADU—
Indoor emergency shelters————
Home✓ ADU—
Indoor emergency housing————
Home✓ ADU—
Transitional housing————
Home✓ ADU—
Permanent supportive housing————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit RMC 18.41.030(D)(1)(a)
Minimum density
  • Not set2 RMC 18.41.030(D)(2)(a)
  • 2 units per acre3 RMC 18.41.030(D)(2)(b)
  • 8 units per acre4 RMC 18.41.030(D)(2)(c)
Not set RMC 18.41.030(D)
for Co-Living Housing (group living); Indoor emergency shelters (group living); Indoor emergency housing (group living); Transitional housing (group living); Permanent supportive housing (group living)
Maximum density
  • 1 units per acre, on the net lot area2 RMC 18.41.030(D)(2)(a); 18.48.030(A)
  • 3.48 units per acre, on the net lot area3 RMC 18.41.030(D)(2)(b); 18.48.030(A)
  • 25 units per acre, on the net lot area4 RMC 18.41.030(D)(2)(c); 18.48.030(A)
Not set RMC 18.44.040(G)
for Co-Living Housing (group living); Indoor emergency shelters (group living); Indoor emergency housing (group living); Transitional housing (group living); Permanent supportive housing (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 20 ft5 RMC 18.48.040(E)
  • 10 ft6 RMC 18.41.030(B)(1)
Side setback
  • 20 ft5 RMC 18.48.040(E)
  • 5 ft6 RMC 18.41.030(B)(1)
Street side setback10 ft RMC 18.41.030(B)(1); 18.48.040(B)
Rear setback
  • 20 ft5 RMC 18.48.040(E)
  • 10 ft6 RMC 18.41.030(B)(1)
Maximum height35 ft RMC 18.41.030(B)(5)
Maximum impervious surface50% RMC 18.41.030(B)(2)
Minimum parking1.5 spaces per unit RMC 18.41.030(C)(2); 18.45.020(A)(1)
2 spaces per unit RMC 18.41.030(C)(2); 18.45.020(A)(1)
for Detached Single-Family Unit (1 unit)
0.5 spaces per bed RMC 18.41.030(C)(2); 18.45.020(A)(1)
for Group Home (group living)
0.25 spaces per sleeping unit RMC 18.41.030(C)(2); 18.44.040(G)(2)(b); 18.45.020(A)(1)
for Co-Living Housing (group living)
0 spaces per unit RMC 18.41.040(A)
for Indoor emergency shelters (group living); Indoor emergency housing (group living); Transitional housing (group living); Permanent supportive housing (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units RMC 18.44.110(B)(3)(a); 18.44.110(B)(3)(b)

Building

StandardValueExceptions
Front setback
  • 20 ft5 RMC 18.48.040(E); 18.44.110(A)(2)(c)
  • 10 ft6 RMC 18.41.030(B)(1); 18.44.110(A)(2)(c)
Side setback
  • 20 ft5 RMC 18.48.040(E); 18.44.110(A)(2)(c)
  • 5 ft6 RMC 18.41.030(B)(1); 18.44.110(A)(2)(c)
Rear setback
  • 20 ft5 RMC 18.48.040(E); 18.44.110(A)(2)(c)
  • 10 ft6 RMC 18.41.030(B)(1); 18.44.110(A)(2)(c)
Maximum height35 ft RMC 18.41.030(B)(5); 18.44.110(A)(2)(c)
Minimum parking1 space per unit RMC 18.41.030(C)(2); 18.45.020(A)(1)
Maximum unit size1,000 sq ft RMC 18.44.110(B)(3)(c)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision RMC 18.156.020; 18.16.070 A up to 4 RMC 18.144.040 —
Minimum lot size
No limit RMC 18.41.030(D)(1)(a)
Minimum lot width
Not set RMC 18.41.030(D)(1)
Minimum lot depth
Not set RMC 18.41.030(D)(1)
Minimum frontage
Not set RMC 18.41.030(D)(1)
Subdivision RMC 18.148.040; 18.16.110(A) H 5 or more RMC 18.144.040 —
Minimum lot size
No limit RMC 18.41.030(D)(1)(a)
Minimum lot width
Not set RMC 18.41.030(D)(1)
Minimum lot depth
Not set RMC 18.41.030(D)(1)
Minimum frontage
Not set RMC 18.41.030(D)(1)
Unit lot subdivision RMC 18.156.051(B)(1) A7
Maximum lots
Not set RMC 18.156.051
Maximum units
Not set RMC 18.156.051
Minimum lot size
Not set RMC 18.156.051
Minimum lot width
Not set RMC 18.156.051
Minimum lot depth
Not set RMC 18.156.051
Minimum frontage
Not set RMC 18.156.051
Residential condominium binding site plan RMC 18.168.010; 18.16.070; 18.16.100(A)Only for: Attached Single-Family Unit H
Maximum lots
Not set RMC 18.168.040
—
Minimum lot size
Not set RMC 18.168.040
Clustered housing planned developments (CHPDs) RMC 18.164.020; 18.44.010(C); 18.20.040(C)(1)Only for: Detached Single-Family Unit, Attached Single-Family Unit H —
Minimum parent area
87,120 sq ft RMC 18.164.030(B)(1)
Minimum lot size
No limit RMC 18.41.030(D)(1)(a)
Minimum lot width
Not set RMC 18.41.030(D)(1)
Minimum lot depth
Not set RMC 18.41.030(D)(1)
Minimum frontage
Not set RMC 18.41.030(D)(1)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The lot is served by public sewer, or its on-site septic system will support the additional ADU
    • Not all of these are true:
      • Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is individual_water_and_septic
      • The lot is within an area designated as wetlands, fish and wildlife habitat, flood plain or geologically hazardous area
  2. Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is individual_water_and_septic
  3. Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is public_water_and_individual_septic
  4. Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is public_water_and_sewer
  5. The lot is a pipestem or flag lot
  6. None of these is true:
    • The lot is a pipestem or flag lot
  7. None of these is true:
    • Development on the lot is restricted by other laws because of proximity to on-site sewage system infrastructure, critical areas or other unsuitable physical characteristics