REN - 0.25 · Residential existing neighborhoods (R-EN) zone, 0.25 acre minimum lot size
Rainier, WA · RMC 18.41; 18.41.010 · Official code
By right: 1 unit · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached Single-Family Unit | — | — | — | — | |
| Group Home | — | — | — | — | Home✓ ADU— |
| Co-Living Housing | — | — | — | — | Home✓ ADU— |
| Indoor emergency shelters | — | — | — | — | Home✓ ADU— |
| Indoor emergency housing | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 10,890 sq ft RMC 18.41.010(D)(1)(a)(i)-(iv) | |
| Minimum density | Not set RMC 18.41.010(D) | |
| Maximum density | Not set RMC 18.44.040(G) | for Detached Single-Family Unit (1 unit); Group Home (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Street side setback | ||
| Rear setback | ||
| Maximum height | 35 ft RMC 18.41.010(B)(5) | |
| Maximum impervious surface | 50% RMC 18.41.010(B)(2) | |
| Minimum parking | 0 spaces per unit RMC 18.41.040(A) | 2 spaces per unit RMC 18.41.010(C)(2); 18.45.020(A)(1)
for Detached Single-Family Unit (1 unit) 0.5 spaces per bed RMC 18.41.010(C)(2); 18.45.020(A)(1)
for Group Home (group living) 0.25 spaces per sleeping unit RMC 18.41.010(C)(2); 18.44.040(G)(2)(b); 18.45.020(A)(1)
for Co-Living Housing (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units RMC 18.44.110(B)(3)(a); 18.44.110(B)(3)(b) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | 35 ft RMC 18.41.010(B)(5); 18.44.110(A)(2)(c) | |
| Minimum parking | 1 space per unit RMC 18.41.010(C)(2); 18.45.020(A)(1) | |
| Maximum unit size | 1,000 sq ft RMC 18.44.110(B)(3)(c) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision RMC 18.156.020; 18.16.070 | A | up to 4 RMC 18.144.040 | — | Minimum lot size 10,890 sq ft RMC 18.41.010(D)(1)(a)(i)-(iv) Minimum lot width Not set RMC 18.41.010(D)(1) Minimum lot depth Not set RMC 18.41.010(D)(1) Minimum frontage Not set RMC 18.41.010(D)(1) |
| Subdivision RMC 18.148.040; 18.16.110(A) | H | 5 or more RMC 18.144.040 | — | Minimum lot size 10,890 sq ft RMC 18.41.010(D)(1)(a)(i)-(iv) Minimum lot width Not set RMC 18.41.010(D)(1) Minimum lot depth Not set RMC 18.41.010(D)(1) Minimum frontage Not set RMC 18.41.010(D)(1) |
| Unit lot subdivision RMC 18.156.051(B)(1) | A9 | Maximum lots Not set RMC 18.156.051 |
Maximum units Not set RMC 18.156.051 |
Minimum lot size Not set RMC 18.156.051 Minimum lot width Not set RMC 18.156.051 Minimum lot depth Not set RMC 18.156.051 Minimum frontage Not set RMC 18.156.051 |
| Clustered housing planned developments (CHPDs) RMC 18.164.020; 18.44.010(C); 18.20.040(C)(1)Only for: Detached Single-Family Unit | H | — | Minimum parent area 87,120 sq ft RMC 18.164.030(B)(1) |
Minimum lot size 10,890 sq ft RMC 18.41.010(D)(1)(a)(i)-(iv) Minimum lot width Not set RMC 18.41.010(D)(1) Minimum lot depth Not set RMC 18.41.010(D)(1) Minimum frontage Not set RMC 18.41.010(D)(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The lot is served by public sewer, or its on-site septic system will support the additional ADU
- Not all of these are true:
- Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is individual_water_and_septic
- The lot is within an area designated as wetlands, fish and wildlife habitat, flood plain or geologically hazardous area
- Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is individual_water_and_septic
- Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is public_water_and_individual_septic
- Water and sewage service of the lot: individual water and septic, public water and individual septic, or public water and sewer is public_water_and_sewer
- The lot is a pipestem or flag lot
- None of these is true:
- The lot is a pipestem or flag lot
- None of these is true:
- On a corner lot, the street-side yard abuts a state highway or major arterial
- On a corner lot, the street-side yard abuts a state highway or major arterial
- None of these is true:
- Development on the lot is restricted by other laws because of proximity to on-site sewage system infrastructure, critical areas or other unsuitable physical characteristics