Sign in

CMU · Central Mixed Use (CMU)

Ridgefield, WA · RDC 18.235 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Townhouse
Home✓1 ADU—
————
Multifamily Residential
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ✓1 ADU—
—
Boarding House————
Home✓ ADU—
Community Residential Facility————
Home✓3 ADU—
Nursing and Personal Care Facility————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size5,000 sq ft RDC 18.235.020(D)(1)
3,000 sq ft RDC 18.235.020(D)(4)(a)
for Townhouse (1 unit)1; Multifamily Residential (4+ units)1
Minimum lot width50 ft RDC 18.235.020(D)(2)
25 ft RDC 18.235.020(D)(4)(b)
for Townhouse (1 unit)1; Multifamily Residential (4+ units)1
Minimum lot depth90 ft RDC 18.235.020(D)(3)
80 ft RDC 18.235.020(D)(4)(c)
for Townhouse (1 unit)1; Multifamily Residential (4+ units)1
Minimum density8 units per acre RDC 18.235.020(F)(1)
Not set RDC 18.235.020
for Boarding House (group living); Community Residential Facility (group living)3; Nursing and Personal Care Facility (group living)
Maximum density
  • 24 units per acre, a fraction of 0.5 or more rounds up, on the net lot area4 RDC 18.235.020(F)(1); 18.235.020(O)(3); 18.235.020(P)(3)(ii)
  • 16 units per acre, on the net lot area5 RDC 18.235.020(F)(1)
Not set RDC 18.235.020
for Boarding House (group living); Community Residential Facility (group living)3; Nursing and Personal Care Facility (group living)

3. Building standards

StandardValueExceptions
Front setbackMinimum front yard setback (street). (1), (2) 0—5 feet RDC Table 18.235.020-1
Maximum front setback
  • 0 ft6 RDC Table 18.235.020-1 note (3)
  • 10 ft7 RDC Table 18.235.020-1 note (3)
Side setback
  • 5 ft8 RDC Table 18.235.020-1
  • 0 ft9 RDC Table 18.235.020-1
Rear setback
  • 5 ft8 RDC Table 18.235.020-1
  • 0 ft9 RDC Table 18.235.020-1
Maximum height
  • Not read10 RDC 18.235.050(E); Figure 18.235.050-1
  • 65 ft11 RDC Table 18.235.020-1
Minimum height
  • Minimum height for new corner buildings shall be thirty feet or at least two stories.6 RDC Table 18.235.020-1 note (4)
  • 20 ft7 RDC Table 18.235.020-1 note (4)
Maximum impervious surface100% RDC Table 18.235.020-1
Maximum floor area ratioNo limit RDC 18.235.020(F)(2)
Minimum parking1 space per unit RDC 18.720.030(A); 18.235.020(K)(1)
1 space per sleeping unit RDC 18.720.030(A)
for Boarding House (group living)
  • 1 ÷ 7 spaces per resident12 RDC 18.720.030(A)(3)
  • 1 ÷ 5 spaces per resident13 RDC 18.720.030(A)(3)
  • 1 ÷ 4 spaces per resident14 RDC 18.720.030(A)(3)
for Community Residential Facility (group living)3
0.5 spaces per bed RDC 18.720.030(F)(3)
for Nursing and Personal Care Facility (group living)
Minimum open space0% RDC 18.235.020(L)(2); Table 18.725.055-1
Maximum units per buildingNot set RDC 18.235.020
4 units RDC 18.205.030(DD)(3)(c)
for Townhouse (1 unit)1

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision/plat RDC 18.610.010(B)(2) A 2 to 9 RDC 18.100.046; RDC 18.100.046; 18.610.010 —
Minimum lot size
5,000 sq ft RDC 18.235.020(D)(1)
Minimum lot width
50 ft RDC 18.235.020(D)(2)
Minimum lot depth
90 ft RDC 18.235.020(D)(3)
Subdivision RDC 18.620.050(A) H 10 or more RDC 18.100.046; 18.620.010 —
Minimum lot size
5,000 sq ft RDC 18.235.020(D)(1)
Minimum lot width
50 ft RDC 18.235.020(D)(2)
Minimum lot depth
90 ft RDC 18.235.020(D)(3)
Large lot plat RDC 18.615.010(C)(2) A 2 or more RDC 18.615.010(A) —
Minimum lot size
217,800 sq ft RDC 18.615.010(A)
Binding site plan RDC 18.550.010(C)(2) A — —
Minimum lot size
5,000 sq ft RDC 18.235.020(D)(1)
Minimum lot width
50 ft RDC 18.235.020(D)(2)
Minimum lot depth
90 ft RDC 18.235.020(D)(3)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The residential use is the ground-floor residential part of a horizontal mixed-use development
    None of these is true:
    • The building has frontage on Pioneer Street or Main Avenue
  2. Residential units are on upper stories above ground-floor non-residential use (no ground-floor residential)
  3. Any of these is true:
    • None of these is true:
      • The building has frontage on Pioneer Street or Main Avenue
    • Residential units are on upper stories above ground-floor non-residential use (no ground-floor residential)
  4. Any of these is true:
    • The project uses an approved senior housing bonus (age 55+ restricted, recorded covenant)
    • The project receives density by the CMU open space density transfer
  5. None of these is true:
    • The project uses an approved senior housing bonus (age 55+ restricted, recorded covenant)
    • The project receives density by the CMU open space density transfer
  6. Corner lot: a lot abutting two or more streets at their intersection, or abutting a street with an interior angle of 130 degrees or less
  7. None of these is true:
    • Corner lot: a lot abutting two or more streets at their intersection, or abutting a street with an interior angle of 130 degrees or less
  8. The side or rear lot line abuts an RLD, RMD, PF or POS zone
  9. None of these is true:
    • The side or rear lot line abuts an RLD, RMD, PF or POS zone
  10. All of these are true:
    • The lot is in the Lake River view protection overlay district (Sargent to Mill Street, Main Avenue to the BNSF tracks)
    None of these is true:
    • The project uses an approved senior housing bonus (age 55+ restricted, recorded covenant)
  11. Any of these is true:
    • None of these is true:
      • The lot is in the Lake River view protection overlay district (Sargent to Mill Street, Main Avenue to the BNSF tracks)
    • The project uses an approved senior housing bonus (age 55+ restricted, recorded covenant)
  12. Age group of the residents served by the community residential facility is under_12
  13. Age group of the residents served by the community residential facility is age_12_to_17
  14. Age group of the residents served by the community residential facility is age_18_plus