Sign in

RLD-8 · Residential Low Density - 8 (RLD-8)

Ridgefield, WA · RDC 18.210 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-Family Detached Residential
Home✓ ADUA
————
Manufactured home
Home✓ ADUA
————
Townhouse
Home✓ ADUA
————
Duplex—
Home✓ ADUA
———
Triplex——
Home✓ ADUA
——
Cottage Housing——
Home✓ ADU—
Home✓ ADU—
—
Manufactured Home Park———
HomeH ADU—
—
Boarding House————
Home✓ ADU—
Community Residential Facility————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set RDC 18.730.020
No limit RDC 18.206.040(B)(4)(b)
for Cottage Housing (4+ units)
Minimum unitsNot set RDC 18.730.020
3 units RDC 18.206.040(B)(4)(a)
for Cottage Housing (4+ units)
Minimum lot size5,000 sq ft RDC Table 18.210.030-1
No limit RDC Table 18.206.060-A
for Townhouse (1 unit); Cottage Housing (3, 4+ units)
  • No limit1 RDC 18.210.130(C)(2)(i)
  • 4,700 sq ft2 RDC 18.210.130(C)(2)(ii)
  • 5,000 sq ft3 RDC Table 18.210.030-1
for Duplex (2 units)
Minimum lot width50 ft RDC Table 18.210.030-1
No limit RDC Table 18.206.060-A
for Townhouse (1 unit); Cottage Housing (3, 4+ units)
Minimum density6 units per acre RDC Table 18.210.030-1
Not set RDC Table 18.210.030-1
for Boarding House (group living); Community Residential Facility (group living)
Maximum density8 units per acre, on the net lot area RDC Table 18.210.030-1
  • No limit4 RDC 18.210.130(C)(2)
  • 8 × 2 units per acre, on the net lot area5 RDC Table 18.210.030-1; 18.206.050(B)(1)
  • 8 units per acre, on the net lot area6 RDC Table 18.210.030-1
for Duplex (2 units)
  • 8 × 3 units per acre, on the net lot area7 RDC Table 18.210.030-1; 18.206.050(B)(1)
  • 8 units per acre, on the net lot area8 RDC Table 18.210.030-1
for Triplex (3 units)
8 × 2 units per acre, on the net lot area RDC Table 18.210.030-1; 18.206.040(B)(3)(a)
for Cottage Housing (3, 4+ units)
Not set RDC Table 18.210.030-1
for Boarding House (group living); Community Residential Facility (group living)
Minimum development sizeNot set RDC Table 18.210.030-1
435,600 sq ft RDC 18.730.020(B)
for Manufactured Home Park (4+ units)
Maximum residents2 persons RDC 18.205.030(E)
10 persons RDC 18.205.030(H)(1); 18.100.014
for Community Residential Facility (group living)
Maximum sleeping units2 sleeping units RDC 18.205.030(E)
Not set RDC 18.205.030(H)
for Community Residential Facility (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 25 ft9 RDC 18.210.060(B)
  • 5 ft10 RDC 18.210.040(E)(2)
  • 10 ft11 RDC Table 18.210.030-1
Side setback
  • 25 ft9 RDC 18.210.060(B)
  • 5 ft12 RDC Table 18.210.030-1; 18.210.030(E)
  • 25 ft9 RDC 18.210.060(B); 18.206.060(C)(2)
  • 0 ft13 RDC 18.206.060(C)(1); Table 18.206.060-A
  • 5 ft14 RDC 18.206.060(C)(1); Table 18.206.060-A
for Townhouse (1 unit)
Street side setback
  • 25 ft9 RDC 18.210.060(B)
  • 10 ft12 RDC Table 18.210.030-1
Rear setback
  • 25 ft9 RDC 18.210.060(B)
  • 0 ft10 RDC 18.210.040(E)(1)
  • 5 ft11 RDC Table 18.210.030-1
  • 25 ft9 RDC 18.210.060(B); 18.206.060(C)(2)
  • 0 ft10 RDC 18.210.040(E)(1)
  • 10 ft11 RDC Table 18.206.060-A
for Townhouse (1 unit)
Building separationNot set RDC Table 18.210.030-1
10 ft RDC 18.206.060(C)(3)
for Townhouse (1 unit); Cottage Housing (3, 4+ units); Manufactured Home Park (4+ units)
Maximum height35 ft RDC Table 18.210.030-1
25 ft RDC 18.206.040(B)(6)(a)
for Cottage Housing (3, 4+ units)
Maximum impervious surface65% RDC Table 18.210.030-1
Minimum parking1 space per unit RDC 18.720.030(A); 18.720.030(A)(1); 18.210.090(A)
  • 1 ÷ 7 spaces per resident15 RDC 18.720.030(A)(3)
  • 1 ÷ 5 spaces per resident16 RDC 18.720.030(A)(3)
  • 1 ÷ 4 spaces per resident17 RDC 18.720.030(A)(3)
for Community Residential Facility (group living)
Maximum unit sizeNot set RDC Table 18.210.030-1
1,200 sq ft RDC 18.206.040(B)(2)(a)
for Cottage Housing (3, 4+ units)
Minimum open space50% RDC Table 18.725.055-1; 18.725.055(A)
Maximum units per buildingNot set RDC Table 18.210.030-1
4 units RDC 18.205.030(DD)(3)(a)
for Townhouse (1 unit)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units RDC 18.206.030(B)(1)

Building

StandardValueExceptions
Front setback
  • 25 ft9 RDC 18.210.060(B)
  • 5 ft10 RDC 18.210.040(E)(2)
  • 10 ft11 RDC Table 18.210.030-1
Side setback
  • 25 ft9 RDC 18.210.060(B)
  • 5 ft12 RDC Table 18.210.030-1; 18.210.030(E)
Rear setback
  • 25 ft9 RDC 18.210.060(B)
  • 0 ft10 RDC 18.210.040(E)(1)
  • 5 ft11 RDC Table 18.210.030-1
Maximum height24 ft RDC 18.206.030(B)(6)
Minimum parking
  • 0 spaces per unit18 RDC 18.720.030(A)(5)
  • 1 space per unit19 RDC 18.720.030(A)(5)
Maximum unit sizethe largest of 0.5 × floor area of the main house, 1,000 sq ft RDC 18.206.030(B)(4)
Attached to the main houseNot required RDC 18.206.030(B)(2)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision/plat RDC 18.610.010(B)(2) A 2 to 9 RDC 18.100.046; RDC 18.100.046; 18.610.010 8 units per acre, on the net lot area RDC Table 18.210.030-1
Minimum density
6 units per acre RDC Table 18.210.030-1
Minimum lot size
5,000 sq ft RDC Table 18.210.030-1
Maximum lot size
7,500 sq ft RDC Table 18.210.030-1; 18.210.030(B)
Minimum lot width
50 ft RDC Table 18.210.030-1
Subdivision RDC 18.620.050(A) H20 10 or more RDC 18.100.046; 18.620.010 8 units per acre, on the net lot area RDC Table 18.210.030-1
Minimum density
6 units per acre RDC Table 18.210.030-1
Minimum lot size
5,000 sq ft RDC Table 18.210.030-1
Maximum lot size
7,500 sq ft RDC Table 18.210.030-1; 18.210.030(B)
Minimum lot width
50 ft RDC Table 18.210.030-1
Binding site plan RDC 18.550.010(C)(2) A21 — 8 units per acre, on the net lot area RDC Table 18.210.030-1
Minimum density
6 units per acre RDC Table 18.210.030-1
Minimum lot size
5,000 sq ft RDC Table 18.210.030-1
Minimum lot width
50 ft RDC Table 18.210.030-1
Planned unit development (PUD) process RDC 18.401.020(B); 18.401.050(D)(1) H — the largest of 8, the smallest of 8 × 1.2, 8 units per acre, on the net lot area RDC 18.401.080(A)(2); 18.401.100(A)(6); Table 18.210.030-1
Minimum density
6 units per acre RDC 18.401.080(A)(1); Table 18.210.030-1
Minimum lot size
the largest of 0.65 × 5,000, 4,000 sq ft RDC 18.401.100(A)(4); Table 18.210.030-1
Maximum lot size
7,500 sq ft RDC Table 18.210.030-1; 18.210.030(B)
Minimum lot width
Not set RDC 18.401.100(A)(5)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The lot is in the Downtown Transition Area (Figure 18.210.130-B)
    • Corner lot: a lot abutting two or more streets at their intersection, or abutting a street with an interior angle of 130 degrees or less
  2. All of these are true:
    • Not all of these are true:
      • The lot is in the Downtown Transition Area (Figure 18.210.130-B)
      • Corner lot: a lot abutting two or more streets at their intersection, or abutting a street with an interior angle of 130 degrees or less
    • The lot is in the Downtown Transition Area (Figure 18.210.130-B)
  3. All of these are true:
    • Not all of these are true:
      • The lot is in the Downtown Transition Area (Figure 18.210.130-B)
      • Corner lot: a lot abutting two or more streets at their intersection, or abutting a street with an interior angle of 130 degrees or less
    None of these is true:
    • The lot is in the Downtown Transition Area (Figure 18.210.130-B)
  4. All of these are true:
    • The lot is in the Downtown Transition Area (Figure 18.210.130-B)
    • Any of these is true:
      • Corner lot: a lot abutting two or more streets at their intersection, or abutting a street with an interior angle of 130 degrees or less
      • Lot area is at least 4,700 sf
  5. All of these are true:
    • Not all of these are true:
      • The lot is in the Downtown Transition Area (Figure 18.210.130-B)
      • Any of these is true:
        • Corner lot: a lot abutting two or more streets at their intersection, or abutting a street with an interior angle of 130 degrees or less
        • Lot area is at least 4,700 sf
    • The lot existed (was created) as of May 27, 2021
  6. All of these are true:
    • Not all of these are true:
      • The lot is in the Downtown Transition Area (Figure 18.210.130-B)
      • Any of these is true:
        • Corner lot: a lot abutting two or more streets at their intersection, or abutting a street with an interior angle of 130 degrees or less
        • Lot area is at least 4,700 sf
    None of these is true:
    • The lot existed (was created) as of May 27, 2021
  7. The lot existed (was created) as of May 27, 2021
  8. None of these is true:
    • The lot existed (was created) as of May 27, 2021
  9. The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
  10. All of these are true:
    • The rear of the lot faces an alley and automobile access is taken only from the alley (lot noted on the plat for reduced setbacks)
    None of these is true:
    • The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
  11. None of these is true:
    • The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
    • The rear of the lot faces an alley and automobile access is taken only from the alley (lot noted on the plat for reduced setbacks)
  12. None of these is true:
    • The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
  13. All of these are true:
    • The side yard is where the dwelling attaches to another dwelling by a common wall
    None of these is true:
    • The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
  14. None of these is true:
    • The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
    • The side yard is where the dwelling attaches to another dwelling by a common wall
  15. Age group of the residents served by the community residential facility is under_12
  16. Age group of the residents served by the community residential facility is age_12_to_17
  17. Age group of the residents served by the community residential facility is age_18_plus
  18. On-street parking is available abutting the lot
  19. None of these is true:
    • On-street parking is available abutting the lot
  20. None of these is true:
    • Critical areas are within the project boundaries
  21. The improvements will be one or more condominiums or owned by an association or other legal entity