RMD-16 · Residential Medium Density (RMD-16)
Ridgefield, WA · RDC 18.220 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-Family Detached Residential | — | — | — | — | |
| Manufactured home | — | — | — | — | |
| Townhouse | — | — | — | — | |
| Multifamily Residential | — | ||||
| Duplex | — | — | — | — | |
| Triplex | — | — | — | — | |
| Cottage Housing | — | — | — | ||
| Manufactured Home Park | — | — | — | — | |
| Boarding House | — | — | — | — | HomeH ADU— |
| Community Residential Facility | — | — | — | — | Home✓ ADU— |
| Nursing and Personal Care Facility | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set RDC 18.730.020 | |
| Minimum units | Not set RDC 18.730.020 | |
| Minimum lot size | 2,500 sq ft RDC Table 18.220.030-1 | No limit RDC Table 18.206.060-A
2,000 sq ft RDC 18.235.060(E)(1)
5,000 sq ft RDC 18.235.060(E)(2)
for Multifamily Residential (1, 2, 3, 4+ units)3 |
| Minimum lot width | 30 ft RDC Table 18.220.030-1 | No limit RDC Table 18.206.060-A
20 ft RDC 18.235.060(E)(1)
50 ft RDC 18.235.060(E)(2)
for Multifamily Residential (1, 2, 3, 4+ units)3 |
| Minimum density | 8 units per acre RDC Table 18.220.030-1 | 0 units per acre RDC 18.235.060(G)(2)
for Multifamily Residential (1, 2, 3, 4+ units)3 |
| Maximum density | 28 units per acre, on the net lot area RDC 18.235.060(G)(1) | 16 units per acre, on the net lot area RDC Table 18.220.030-1
No limit RDC 18.235.060(G)(2)
for Multifamily Residential (1, 2, 3, 4+ units)3 for Duplex (2 units)1 for Triplex (3 units)1 16 × 2 units per acre, on the net lot area RDC Table 18.220.030-1; 18.206.040(B)(3)(a)
for Cottage Housing (3, 4+ units)1 28 × 2 units per acre, on the net lot area RDC 18.235.060(G)(1); 18.206.040(B)(3)(a)
for Cottage Housing (3, 4+ units)2 for Multifamily Residential (4+ units)1 |
| Minimum development size | Not set RDC Table 18.220.030-1 | 435,600 sq ft RDC 18.730.020(B)
for Manufactured Home Park (4+ units)1 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft RDC 18.235.060(F)
0 ft RDC 18.235.060(F)
for Multifamily Residential (1, 2, 3, 4+ units)3 | |
| Maximum front setback | Not set RDC Table 18.220.030-1 | 20 ft RDC 18.235.060(F)
|
| Side setback | for Townhouse (1 unit)1 5 ft RDC 18.235.060(F)
| |
| Street side setback | for Townhouse (1 unit)1 10 ft RDC 18.235.060(F)
0 ft RDC 18.235.060(F)
for Multifamily Residential (1, 2, 3, 4+ units)3 | |
| Rear setback | for Townhouse (1 unit)1 5 ft RDC 18.235.060(F)
Not set RDC 18.235.060(F)
for Multifamily Residential (1, 2, 3, 4+ units)3 | |
| Building separation | 20 ft RDC 18.220.060(A) | 10 ft RDC 18.206.060(C)(3)
|
| Maximum height | 45 ft RDC 18.235.060(F) | for Single-Family Detached Residential (1 unit)1; Manufactured home (1 unit)1; Townhouse (1 unit)1; Duplex (2 units)1; Triplex (3 units)1; Manufactured Home Park (4+ units)1; Multifamily Residential (4+ units)1; Boarding House (group living); Community Residential Facility (group living); Nursing and Personal Care Facility (group living)1 |
| Maximum stories | Not set RDC Table 18.220.030-1 | 1 story RDC 18.205.030(EE)(2)
|
| Maximum lot coverage | Not set RDC Table 18.220.030-1 | 65% RDC 18.235.060(F)
80% RDC 18.235.060(F)
for Multifamily Residential (1, 2, 3, 4+ units)3 |
| Maximum impervious surface | 75% RDC Table 18.220.030-1 | 90% RDC 18.235.060(F)
for Multifamily Residential (1, 2, 3, 4+ units)3 |
| Minimum parking | 1 space per unit RDC 18.720.030(A); 18.720.030(A)(1); 18.220.100(A) | 1 space per sleeping unit RDC 18.720.030(A)
for Boarding House (group living) for Community Residential Facility (group living) |
| Maximum unit size | Not set RDC Table 18.220.030-1 | |
| Minimum open space | 25% RDC Table 18.725.055-1; 18.725.055(A) | 10% RDC 18.235.060(O)(2)
for Multifamily Residential (1, 2, 3, 4+ units)3 |
| Maximum units per building | Not set RDC Table 18.220.030-1 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units RDC 18.206.030(B)(1) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | 24 ft RDC 18.206.030(B)(6) | |
| Minimum parking | ||
| Maximum unit size | the largest of 0.5 × floor area of the main house, 1,000 sq ft RDC 18.206.030(B)(4) | |
| Attached to the main house | Not required RDC 18.206.030(B)(2) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision/plat RDC 18.610.010(B)(2) | A | 2 to 9 RDC 18.100.046; RDC 18.100.046; 18.610.010 | 16 units per acre, on the net lot area RDC Table 18.220.030-1 Minimum density 8 units per acre RDC Table 18.220.030-1 |
Minimum lot size 2,500 sq ft RDC Table 18.220.030-1 Minimum lot width 30 ft RDC Table 18.220.030-1 |
| Subdivision RDC 18.620.050(A) | H34 | 10 or more RDC 18.100.046; 18.620.010 | 16 units per acre, on the net lot area RDC Table 18.220.030-1 Minimum density 8 units per acre RDC Table 18.220.030-1 |
Minimum lot size 2,500 sq ft RDC Table 18.220.030-1 Minimum lot width 30 ft RDC Table 18.220.030-1 |
| Large lot plat RDC 18.615.010(C)(2) | A | 2 or more RDC 18.615.010(A) | — | Minimum lot size 217,800 sq ft RDC 18.615.010(A) |
| Binding site plan RDC 18.550.010(C)(2) | A35 | — | 16 units per acre, on the net lot area RDC Table 18.220.030-1 Minimum density 8 units per acre RDC Table 18.220.030-1 |
Minimum lot size 2,500 sq ft RDC Table 18.220.030-1 Minimum lot width 30 ft RDC Table 18.220.030-1 |
| Planned unit development (PUD) process RDC 18.401.020(B); 18.401.050(D)(1) | H1 | — | the largest of 16, the smallest of 16 × 1.2, 8 units per acre, on the net lot area RDC 18.401.080(A)(2); 18.401.100(A)(6); Table 18.220.030-1 Minimum density 8 units per acre RDC 18.401.080(A)(1); Table 18.220.030-1 |
Minimum lot size Not set RDC 18.401.100(A)(4) Minimum lot width Not set RDC 18.401.100(A)(5) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The site is in an approved Ridgefield Mixed-Use Overlay (RMUO) master plan in the Pioneer and 45th or Ridgefield Junction subarea
- The site is in an approved Ridgefield Mixed-Use Overlay (RMUO) master plan in the Pioneer and 45th or Ridgefield Junction subarea
- All of these are true:
- The site is in an approved Ridgefield Mixed-Use Overlay (RMUO) master plan in the Pioneer and 45th or Ridgefield Junction subarea
- Residential units are on upper stories above ground-floor non-residential use (no ground-floor residential)
- All of these are true:
- The site is in an approved Ridgefield Mixed-Use Overlay (RMUO) master plan in the Pioneer and 45th or Ridgefield Junction subarea
- Residential units are on upper stories above ground-floor non-residential use (no ground-floor residential)
- The lot existed (was created) as of May 27, 2021
- None of these is true:
- The lot existed (was created) as of May 27, 2021
- The project uses an approved senior housing bonus (age 55+ restricted, recorded covenant)
- None of these is true:
- The project uses an approved senior housing bonus (age 55+ restricted, recorded covenant)
- The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
- All of these are true:
- The lot's street frontage is an arterial, minor arterial or collector street (a major corridor in the commercial districts)
- The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
- All of these are true:
- The rear of the lot faces an alley and automobile access is taken only from the alley (lot noted on the plat for reduced setbacks)
- The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
- The lot's street frontage is an arterial, minor arterial or collector street (a major corridor in the commercial districts)
- None of these is true:
- The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
- The lot's street frontage is an arterial, minor arterial or collector street (a major corridor in the commercial districts)
- The rear of the lot faces an alley and automobile access is taken only from the alley (lot noted on the plat for reduced setbacks)
- The lot's street frontage is an arterial, minor arterial or collector street (a major corridor in the commercial districts)
- None of these is true:
- The lot's street frontage is an arterial, minor arterial or collector street (a major corridor in the commercial districts)
- None of these is true:
- The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
- All of these are true:
- The side yard is where the dwelling attaches to another dwelling by a common wall
- The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
- None of these is true:
- The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
- The side yard is where the dwelling attaches to another dwelling by a common wall
- The side yard is where the dwelling attaches to another dwelling by a common wall
- None of these is true:
- The side yard is where the dwelling attaches to another dwelling by a common wall
- The side lot line is adjacent to an RLD, RMD or P/OS zone
- None of these is true:
- The side lot line is adjacent to an RLD, RMD or P/OS zone
- None of these is true:
- The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
- The lot's street frontage is an arterial, minor arterial or collector street (a major corridor in the commercial districts)
- All of these are true:
- The rear of the lot faces an alley and automobile access is taken only from the alley (lot noted on the plat for reduced setbacks)
- The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
- None of these is true:
- The lot abuts or is adjacent to the right-of-way of a major corridor: Hillhurst Road, Pioneer Street east of the Gee Creek crossing, or Royle Road
- The rear of the lot faces an alley and automobile access is taken only from the alley (lot noted on the plat for reduced setbacks)
- The building has a pitched roof
- None of these is true:
- The building has a pitched roof
- The first floor is used for parking with no residential units
- None of these is true:
- The first floor is used for parking with no residential units
- Age group of the residents served by the community residential facility is under_12
- Age group of the residents served by the community residential facility is age_12_to_17
- Age group of the residents served by the community residential facility is age_18_plus
- On-street parking is available abutting the lot
- None of these is true:
- On-street parking is available abutting the lot
- Any of these is true:
- None of these is true:
- Critical areas are within the project boundaries
- The site is in an approved Ridgefield Mixed-Use Overlay (RMUO) master plan in the Pioneer and 45th or Ridgefield Junction subarea
- None of these is true:
- The improvements will be one or more condominiums or owned by an association or other legal entity