WLS · Waterfront Low Scale (WLS)
Ridgefield, WA · RDC 18.235 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Multifamily Residential | — | ||||
| Floating Home Moorage | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Nursing and Personal Care Facility | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | No limit RDC 18.235.040(D)(1) | |
| Minimum lot width | 50 ft RDC 18.235.040(D)(2) | |
| Minimum density | Not set RDC 18.235.040 | 8 units per acre RDC 18.205.030(V)(2)
for Multifamily Residential (1, 2, 3, 4+ units)1 |
| Maximum density | Not set RDC 18.235.040 | 16 units per acre RDC 18.205.030(V)(2)
for Multifamily Residential (1, 2, 3, 4+ units)1 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft RDC Table 18.235.040-1 | 10 ft RDC Table 18.235.040-1 note (1)
for Floating Home Moorage (1, 2, 3, 4+ units) |
| Side setback | 0 ft RDC Table 18.235.040-1 | |
| Rear setback | 0 ft RDC Table 18.235.040-1 | |
| Maximum height | ||
| Maximum impervious surface | 85% RDC Table 18.235.040-1 | |
| Minimum parking | 1 space per unit RDC 18.720.030(A); 18.235.040(J)(1) | 1.5 spaces per unit RDC 18.235.040(J)(5); 18.720.030(H)(2)
for Floating Home Moorage (1, 2, 3, 4+ units) 0.5 spaces per bed RDC 18.720.030(F)(3)
for Nursing and Personal Care Facility (group living) |
| Maximum lot size | No limit RDC 18.235.040(D)(1) | |
| Minimum open space | 15% RDC 18.235.040(K)(2) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision/plat RDC 18.610.010(B)(2) | A | 2 to 9 RDC 18.100.046; RDC 18.100.046; 18.610.010 | — | Minimum lot size No limit RDC 18.235.040(D)(1) Minimum lot width 50 ft RDC 18.235.040(D)(2) |
| Subdivision RDC 18.620.050(A) | H | 10 or more RDC 18.100.046; 18.620.010 | — | Minimum lot size No limit RDC 18.235.040(D)(1) Minimum lot width 50 ft RDC 18.235.040(D)(2) |
| Large lot plat RDC 18.615.010(C)(2) | A | 2 or more RDC 18.615.010(A) | — | Minimum lot size 217,800 sq ft RDC 18.615.010(A) |
| Binding site plan RDC 18.550.010(C)(2) | A | — | — | Minimum lot size No limit RDC 18.235.040(D)(1) Minimum lot width 50 ft RDC 18.235.040(D)(2) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Residential units are on upper stories above ground-floor non-residential use (no ground-floor residential)
- The structure is in a WLS view corridor (30 feet each side of the westerly projections of Mill, Simons, Pioneer and Sargent Streets)
- None of these is true:
- The structure is in a WLS view corridor (30 feet each side of the westerly projections of Mill, Simons, Pioneer and Sargent Streets)