Sign in

WMU · Waterfront Mixed Use (WMU)

Ridgefield, WA · RDC 18.235 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Multifamily Residential
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Townhouse
Home✓2 ADU—
————
Floating Home Moorage
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Nursing and Personal Care Facility————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size5,000 sq ft RDC Table 18.235.030-2
Minimum lot width50 ft RDC Table 18.235.030-2
Minimum lot depth30 ft RDC Table 18.235.030-2
Minimum densityNot set RDC 18.235.030
4 units per acre RDC 18.205.030(V)(3)
for Multifamily Residential (1, 2, 3, 4+ units)1
Maximum densityNot set RDC 18.235.030
18 units per acre, on the net lot area RDC 18.205.030(V)(3)
for Multifamily Residential (1, 2, 3, 4+ units)1
Minimum development sizeNo limit RDC Table 18.235.030-2

3. Building standards

StandardValueExceptions
Front setback0 ft RDC Table 18.235.030-2
Maximum front setback25 ft RDC Table 18.235.030-2
Side setback
  • 10 ft3 RDC Table 18.235.030-2
  • 0 ft4 RDC Table 18.235.030-2
Rear setback
  • 10 ft3 RDC Table 18.235.030-2
  • 0 ft4 RDC Table 18.235.030-2
Maximum height
  • 25 ft5 RDC 18.235.030(E)(5)
  • 45 ft6 RDC 18.235.030(E)(6)
  • 75 ft7 RDC Table 18.235.030-2
Maximum impervious surface85% RDC Table 18.235.030-2
Minimum parking1 space per unit RDC 18.720.030(A); 18.235.030(G)
0.5 spaces per bed RDC 18.720.030(F)(3)
for Nursing and Personal Care Facility (group living)
Minimum open space15% RDC Table 18.235.030-2; 18.235.030(F)
Maximum units per buildingNot set RDC 18.235.030
4 units RDC 18.205.030(DD)(3)(c)
for Townhouse (1 unit)2

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision/plat RDC 18.610.010(B)(2) A 2 to 9 RDC 18.100.046; RDC 18.100.046; 18.610.010 —
Minimum lot size
5,000 sq ft RDC Table 18.235.030-2
Minimum lot width
50 ft RDC Table 18.235.030-2
Minimum lot depth
30 ft RDC Table 18.235.030-2
Subdivision RDC 18.620.050(A) H 10 or more RDC 18.100.046; 18.620.010 —
Minimum lot size
5,000 sq ft RDC Table 18.235.030-2
Minimum lot width
50 ft RDC Table 18.235.030-2
Minimum lot depth
30 ft RDC Table 18.235.030-2
Large lot plat RDC 18.615.010(C)(2) A 2 or more RDC 18.615.010(A) —
Minimum lot size
217,800 sq ft RDC 18.615.010(A)
Binding site plan RDC 18.550.010(C)(2) A — —
Minimum lot size
5,000 sq ft RDC Table 18.235.030-2
Minimum lot width
50 ft RDC Table 18.235.030-2
Minimum lot depth
30 ft RDC Table 18.235.030-2

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Residential units are on upper stories above ground-floor non-residential use (no ground-floor residential)
  2. The townhouse is a live/work unit whose business is a permitted or limited use, with no residence on the ground floor
  3. The side or rear lot line abuts an RLD or RMD zone
  4. None of these is true:
    • The side or rear lot line abuts an RLD or RMD zone
  5. The structure is in a WMU view corridor (30 feet each side of the westerly projections of Depot, 9th, Cook, Hall, Elm, Maple, Division and Mill Streets)
  6. All of these are true:
    • The structure is in the WMU view shed area south of the westerly projection of Ash Street or north of the westerly projection of Cook Street
    None of these is true:
    • The structure is in a WMU view corridor (30 feet each side of the westerly projections of Depot, 9th, Cook, Hall, Elm, Maple, Division and Mill Streets)
  7. None of these is true:
    • The structure is in a WMU view corridor (30 feet each side of the westerly projections of Depot, 9th, Cook, Hall, Elm, Maple, Division and Mill Streets)
    • The structure is in the WMU view shed area south of the westerly projection of Ash Street or north of the westerly projection of Cook Street