Sign in

TC A-1 · Mixed-use zone (TC-A), TC-A-1 sub-zone

Sammamish, WA · SMC 21.07.020(C); 21.07.050(B) · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Townhouse—
HomeA1 ADU—
HomeA1 ADU—
HomeA1 ADU—
—
Apartment—
HomeA1 ADU—
HomeA1 ADU—
HomeA1 ADU—
—
Community residential facility, I————
HomeA1 ADU—
Community residential facility, II————
HomeA1 ADU—
Senior assisted housing————
HomeA1 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot widthNo limit SMC 21.07.050(B)
Minimum density16 units per acre SMC 21.07.050(B)(5); 21.07.050(H)
Not set SMC 21.07.050(B)(3)
for Community residential facility, I (group living)1; Community residential facility, II (group living)1; Senior assisted housing (group living)1
Maximum density
  • 16 units per acre, a fraction of 0.5 or more rounds up, on the net lot area2 SMC 21.07.050(B)(4); 21.07.050(F)(4)
  • 40 units per acre, a fraction of 0.5 or more rounds up, on the net lot area3 SMC 21.07.050(B)(2); 21.07.050(C)(1); 21.07.050(F)(4)
Not set SMC 21.07.050(B)
for Community residential facility, I (group living)1; Community residential facility, II (group living)1; Senior assisted housing (group living)1

3. Building standards

StandardValueExceptions
Front setback0 ft SMC 21.07.050(B)
Side setback
  • 20 ft4 SMC 21.07.050(B)(14)
  • 10 ft5 SMC 21.07.060(A)(8)(a)(i)(b)
Rear setback
  • 20 ft4 SMC 21.07.050(B)(14)
  • 10 ft5 SMC 21.07.060(A)(8)(a)(i)(b)
Maximum height
  • 70 ft6 SMC 21.07.050(B)(17)
  • 60 ft7 SMC 21.07.050(B)(17)
Maximum stories
  • 6 stories6 SMC 21.07.050(B)(17)
  • 5 stories7 SMC 21.07.050(B)(17)
Minimum parking2 spaces per unit SMC 21.07.080(C)(1)
  • 1.2 spaces per unit8 SMC 21.07.080(C)(1)
  • 1.5 spaces per unit9 SMC 21.07.080(C)(1)
  • 1.7 spaces per unit10 SMC 21.07.080(C)(1)
  • 2 spaces per unit11 SMC 21.07.080(C)(1)
for Apartment (2, 3, 4+ units)1
0.5 × bedrooms in the whole project spaces SMC 21.07.080(C)(1)
for Community residential facility, I (group living)1; Community residential facility, II (group living)1
0.5 × (main dwelling units on the lot + sleeping units in the project) spaces SMC 21.07.080(C)(1)
for Senior assisted housing (group living)1

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision SMC 21.09.010(B)(4) A up to 9 SMC 21.02.060(D)(3)(a) —
Minimum lot size
Not set SMC 21.07.050(B)
Subdivision SMC 21.09.010(B)(4) H 10 or more SMC 21.02.060(B)(32); 21.02.060(D)(3)(a) —
Minimum lot size
Not set SMC 21.07.050(B)
Unit lot subdivision SMC 21.02.060(H)(2); 21.09.010(B)(4) A12 up to 9 SMC 21.02.060(H)(2); 21.02.060(D)(3)(a) —
Minimum lot size
Not set SMC 21.02.060(H)(3)
Unit lot subdivision SMC 21.02.060(H)(2); 21.09.010(B)(4) H12 10 or more SMC 21.02.060(H)(2); 21.02.060(B)(32); 21.02.060(D)(3)(a) —
Minimum lot size
Not set SMC 21.02.060(H)(3)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The use is within 30 feet of the sidewalk on the ground floor of a designated pedestrian-oriented street or corridor
  2. None of these is true:
    • The project obtains bonus dwelling units under SMC 21.07.050.C
  3. The project obtains bonus dwelling units under SMC 21.07.050.C
  4. The property line abuts R-1 through R-8, TC-C or TC-E zones
  5. None of these is true:
    • The property line abuts R-1 through R-8, TC-C or TC-E zones
  6. The site is west of 228th Avenue SE
  7. None of these is true:
    • The site is west of 228th Avenue SE
  8. Bedrooms in one unit is at most 0
  9. Bedrooms in one unit is 1
  10. Bedrooms in one unit is 2
  11. Bedrooms in one unit is at least 3
  12. No dwelling units are stacked on other dwelling units or another use